300 kVA Sanduuqa Cagaaran Beddelka-12/0.12*0.24 kV|Jamaica 2024

300 kVA Sanduuqa Cagaaran Beddelka-12/0.12*0.24 kV|Jamaica 2024

Dalka: Ameerika 2024
Awoodda: 300kVA
Voltage: 12.47/0.48kV
Feature: haanta birta ah ee aan lahayn
U dir sooji

 

 

9

Beddelka tamarta saxda ah waxay xaqiijisaa badbaadada iyo xasiloonida, maadaama saddex{0}} suufka wejiga{1} ku rakiban ay xoojiyaan mustaqbalka xariijimaha smart!

 

01 Guud

1.1 Asalkii Mashruuca

300 kVA pad ku rakiban transformer ayaa la geeyey Ameerika sanadka 2024. Saddexdan weji ee ku rakiban transformer-ka waxa iibsaday macmiil Jamaican ah, TAK. Waxaa xusid mudan in korantada yar ee dual danab ay tahay astaanta gaarka ah ee qalabkan. Awoodda la qiimeeyay ee is beddelka waa 300 kVA oo leh qaboojin ONAN. Korantada aasaasiga ah waa 12GrdY / 6.9kV oo leh ± 2 * 2.5% garaacida kala duwan (NLTC), korantada labaad waa 0.24 / 0.12kV, waxay sameeyeen koox vector ah YNd11, waana feed loop iyo beddelka hore ee dhintay.

Transformers suufka lagu rakibay, sidoo kale loo yaqaano American{0} qaabkii hore loo sii hagaajiyey, waa unug qaybin koronto oo heersare ah oo isku dhafan kuwaas oo isku dhafan{1}}qalabka korantada ee sare, transformers, iyo qaybaha kale ee qaybinta. Waxay u isticmaalaan furayaasha rarka iyo fiyuusyada sida aaladaha ilaalinta aasaasiga ah, oo leh naqshad kooban, hawlgal sahlan, rakibid dabacsan, iyo kharashyo dayactir oo hooseeya. Marka loo eego raadkooda yar iyo la qabsigooda xoogan, -Transfomerayaasha qaabka santuuqa Maraykanka ayaa si weyn loogu isticmaalaa dhismaha shabakada awooda qaybinta magaalooyinka, cusboonaysiinta awooda bulshada, iyo meelaha- meelaha xaddidan sida xarumaha ganacsiga, bulshada la degan yahay, iyo mashaariicda tamarta ku meel gaadhka ah.

Faa'iidooyinka: Cabbirka is haysta oo leh qaab dhismeed aad u sarreeya; Haanta saliidda oo si buuxda loo xidhay iyo naqshad si buuxda u dahaaran oo loogu talagalay hawlgal ammaan ah oo la isku halleyn karo; ku habboon labadaba shabakadda giraanta iyo sahayda korantada ee terminaalka, hubinta hawlgal ku habboon iyo qaybinta awoodda la isku halayn karo; awood xad dhaaf ah oo xoog leh iyo iska caabin heer sare ah oo wareegyada gaaban ee degdega ah; iska caabin heer sare ah; Tamar{0} hufan leh khasaaro hoose, buuxinta ama dhaaftay heerarka hufnaanta casriga ah; madax fiilooyinka oo awood u leh inay xamili karaan 200A culeyska hadda jira, oo leh cimri dherer makaaniyo iyo koronto.

 

 

1.2 Tilmaamaha Farsamada

300 kVA nooca tafatirka beddelka iyo xaashida xogta

loo geeyey
Jamaica
Sannadka
2024
Nooca
suuf ku rakiban transformer
Heerka
IEEE Std C57.12.34-2022
Awood lagu qiimeeyay
300kVA
Soo noqnoqoshada
50 HZ
Marxaladda
3
Quudinta
Loop
Hore
dhintay
Nooca qaboojinta
ONAN
Korantada aasaasiga ah
12GRDY/6.9 kV
Voltage Secondary
0.24/0.12 kV
Qalabka dabaysha
Copper
barokaca xagal
YNd11
Caqabada
4.75%(±7.5%)
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
In ka yar ama la mid ah 0.53KW
Load Lumista
In ka yar ama la mid ah 4.755KW
Agabka
Habaynta caadiga ah

 

1.3 Sawirro

300 kVA suuf ku rakiban jaantuska beddelka sawirka iyo cabbirka.

1 2

 

 

02 Wax-soo-saarka

2.1 Core

Sadexda{0}wajiga shanaad-xuddunta beddelka addinka waxa uu leeyahay nakhshad wareegta magnetka gaarka ah oo lagu garto saddex addin oo waaweyn iyo laba addimo caawiye ah. Dabaylaha lugaha ugu muhiimsan waxay wataan qulqulka birlabeedka aasaasiga ah, halka lugaha kaaliyaha loo isticmaalo in lagu xidho wareegga magnetic, si wax ku ool ah u yareeya luminta qulqulka qulqulka iyo qulqulka wareegga gaaban -.

Xakamaynta xudunta u ah waa qaybo loo isticmaalo in lagu sugo oo lagu xidho xudunta wax beddelka. Badanaa waxay ka samaysan yihiin -awood aan -magneteed sare lahayn, sida birta aan birta lahayn ama aluminium aluminium gaar ah, si ay u bixiyaan xoog makaanik oo aad u wanaagsan iyada oo aan saamayn ku yeelan waxqabadka magnetic xudunta u ah. Naqshadaynta xirmooyinka waxay sidoo kale u baahan tahay inay buuxiso shuruudaha kuleylka kuleylka si loo hubiyo xasilloonida kulaylka inta lagu jiro hawlgalka.

3

 

2.2 Dabaylaha

4

Kooxda Isku xirka YNd11

Xidhiidhka sare -Xiddiga korontadu waxa uu bixiyaa meel dhexdhexaad ah, oo daboolaysa baahiyaha culayska aan dheeli tirnayn, halka -ku xidhka korantada ee hooseeya uu yareeyo iswaafajinta saddexaad, isaga oo hubinaya sahayda tamarta degan.

Wajiga wareega 11ka saac waxa uu yareeyaa faragelinta iswaafajinta ee nidaamka.

Hooseeyo-Naqshadda Dabaylaha Foil Foil

Kuleyl aad u fiican oo kor u kaca heerkulka hooseeya, kordhinta cimriga beddelka

Xoogan gaaban oo gaaban

Sare -Naqshadda Dabaysha Fiilka Voltage

Qaab dhismeedka is haysta waxa uu badbaadiyaa meel bannaan.

Waxqabadka korantada ee deggan oo leh dahaar la isku halleyn karo.

 

2.3 Haanta

Haanta saliiddu waxay qabataa nakhshad si buuxda u xidhan, si wax ku ool ah ayay uga hortagtaa hawada iyo qoyaanka dibadda inay soo galaan, iyada oo hubinaysa{0}} xasiloonida muddada dheer ee saliidda beddelka waxayna kordhinaysaa cimriga qalabka. Loogu talagalay inay noqoto mid cufan iyo meel bannaan -badbaadin, haanta saliidda waxay ka samaysan tahay bir tayadeedu sarreyso{3} Dusha sare waxaa lagu daaweeyaa daahan buufin ah ama kulul -, siinta caabbinta daxalka wanaagsan ee bay'ada adag sida huurka badan, buufinta milixda, ama soo-gaadhista kiimikaad.

5

 

2.4 Kulanka ugu dambeeya

6

Xuddunta iyo Golaha Dabayluhu

Si sugan u ururi xudunta la tijaabiyay ee leh- iyo kuwa hooseeya{1}, adiga oo hubinaya in waxqabadka korantada uu la kulmo qeexida naqshadaynta.

Rakibaadda Haamaha Shidaalka

Ku rakib qalabka wax beddelka ee haanta saliidda, ku xidh fiilooyinka gudaha, oo dhammaystir habka xidhitaanka.

Rakibaadda Qalabka Dibadda

Ku rakib qaybaha sare - Voltage-ka sida furayaasha rarka iyo hadda -Fiyuusyada xaddidaya, iyo sidoo kale kuwa hooseeya{2}

Buuxinta Saliidda iyo Tijaabada Diidmada

Duri saliidda dahaarka, samee tijaabooyinka cadaadiska, oo hubi inay daadsan yihiin si loo hubiyo waxqabadka xidhidhiyaha iyo qaboojinta.

 

 

03 Tijaabinta

green box transformer test
green box transformer routine test

 

 

04 Baakaynta iyo dhoofinta

7

green box transformer shipping
 
 

 

05 Goobta iyo Kooban

Gebagebadii, saddexda{0}xajmiga{1}ku rakibay taransfoorayaasha waa xal lama huraan u ah qaybinta awood la isku halayn karo oo hufan. Iyada oo nashqaddeeda adag iyo tignoolajiyada horumarsan, waxay buuxisay baahiyaha kaabayaasha korantada ee casriga ah ee codsiyada kala duwan. Transformers-yadayada waxaa loo habeeyey si ay u soo bandhigaan waxqabadka ugu wanaagsan iyadoo mudnaanta la siinayo badbaadada iyo joogtaynta. Markaad dooratid saddexdayada-xajisyada wejiga{6}} ee ku rakiban Transformers, waxaad maalgashanaysaa badeecad aan kor u qaadin waxtarka nidaamka korantada oo kaliya balse sidoo kale wax ka taraya mustaqbal cagaaran. Nala wadaag si aan u aragno tayada aan la barbar dhigi karin iyo xalalka cusub ee baahidaada qaybinta awoodda.