Cirifka -Ku rakiban Transformers Iibka ee SCOTECH
• Awoodda la qiimeeyay:10 kVA ilaa 500 KVA
Korontada la qiimeeyay:Ilaa 34.5kV
• Awoodda la qiimeeyay:15 kVA ilaa 1000 kVA
Korontada la qiimeeyay:Ilaa 34.5kV
Aan Bilow Mashruuc Cusub Maanta
SCOTECH, tiirka hormuudka ah{0}ku rakiba alaab-qeybiyaha taransfoorayaasha, ayaa ku siin kara xalalka mashaariicdaada quwadda.
Codsiyada

Awoodda deegaanka
Qaybinta

Waraabka Beeraha
Nidaamka

Ganacsiga iyo Iftiinka
Korontada Warshadaha

Awood-siinta Dadweynaha
Nidaamka Iftiinka Aagga

Korontada wakhtiga gaaban-
Mashaariicda Dhismaha

Tamarta la cusboonaysiin karo
Is dhexgalka
Mashruucyada Transformer-ka ee ku rakiban tiirarka guusha leh ee SCOTECH
Injineerka ilaa Heerarka Sare






Maxaad ugu kalsoon tahay SCOTECH soo saaraha soo saaraha tiirarkaaga
Xalalka beddelka ee la habeeyey
Ma habeyno kaliya koronto-baddeyaasha iyo tamarta-waxaan sidoo kale bixinaa taangiyada birta ah ee aan tolneyn, dareeraha dielectric FR3, cirifka CSP{1}}Transformers-ku rakiban, iyo qalabyo kale. La xidhiidh si aad u sahamiso sida aan ula qabsan karno xalalkayaga baahiyahaaga saxda ah.
Qalabka Ikhtiyaarka ah
Waxa kale oo aanu bixinaa agabka ikhtiyaariga ah ee soo socda, oo ay ku jiraan kuwa hillaaca xidha, tilmaamayaasha heerka saliidda, gudaha hadda jira{0} fiyuusyada xaddidaya, cilladaha gudaha (IFD), heerkulbeegyada, valves buuxinta saliidda, iyo tubooyinka saliidda ee sambalayaasha.
Waayo-aragnimada Wax-soo-saarka oo Ballaaran
Waxaan leenahay 26+ sano oo waayo-aragnimo ah xagga wax-soo-saarka beddelka, gaarsiinta mashaariicda tamarta in ka badan 50 waddan. Waxaan ku siin karnaa xalal habaysan mashruucaaga.
Hal -Adeeg joogsi
Waxaan bixinaa adeeg joogsi{0}oo daboolaya latalinta, xigashada, wax soo saarka, rakibida, hawlgelinta, tababarka, iyo - taageero iibka kadib, loogu talagalay in si buuxda wax looga qabto dhammaan shuruudahaaga.
Xakamaynta Tayada & Tijaabinta Transformers ee Tiirarka Ku Xidhan
Sida soo saaraha tiirka gaarka ah ee ku rakiban transformer-ka, waxaan u hoggaansanahay xakameynta tayada adag
Inta lagu jiro marxalad kasta oo habka-laga bilaabo naqshadeynta, soo iibsiga, iyo wax soo saarka ilaa kormeerka.
Dhammaan transformers-ka tirka ku rakiban ee iibka ah waxa lagu mariyaa imtixaanno adag oo taxane ah
dammaanad qaadida tayada alaabta.
✔ Cabbiraadaha iska caabinta
✔ Imtixaanada saamiga
✔ Tijaabada Polarity
✔ Tijaabada adkaysiga korantada ee keentay
✔ Tijaabada Korantada ee La dabaqay
✔ Cabbirka iska caabinta dahaarka
✔ Tijaabada Saliida
✔ Tijaabada Dhiigbaxa
✔ Maya - Xambaarsan Khasaaraha & Dhiirigelinta Hadda
✔ Lumitaanka Culayska, Korontada Caqabadda & Wadarta Khasaaraha
✔ Xaqiijinta Hufnaanta
FAQ
S: Tiirkaaga -Transformers-yada qaybinta ee rakiban ma la kulmaan heerarka Maraykanka iyo kuwa caalamiga ah?
J: Haa. Transformer kasta waxaa loo qaabeeyey, la soo saaray, oo la tijaabiyey si waafaqsan heerarka ANSI, IEEE, IEC, iyo DOE.
S: Waa maxay muddada dammaanadda alaabtaada?
J: Transformers-yada ku rakiban tiirka waxay wataan dammaanad 24 bilood ah. Inta lagu jiro muddada dammaanadda, haddii cillad kastaa ay ku dhacdo cilladaha alaabta ama shaqada, waxaanu dabooli doonaa kharashka dayactirka ama beddelka.
S: Sideed u baakadaysaa Transformers si loo raro?
J: Tiirkayaga -Transformers ee rakiban waxa lagu baakadeeyay sanduuqyo alwaax ah oo caado u ah oo ay ku jiraan fiimyada alwaax adag la xoojiyay. Gudaha, unugga waxa si sugan loogu xidhay shoog{2}} nuugaysa xumbo iyo alwaaxyo si looga hortago dhaqdhaqaaqa.
S: Tiirkaagu ma yahay - Kor u qaadista tamarta - hufan?
J: Haa. Tiirkayaga - Buurta transformers-ka waxa loo nashqadeeyay wax yar oo aan - lumin rar iyo luminta rarka hooseeya, oo la kulma IEEE/IEC heerar sare oo hufan{3}
S: Waa maxay noocyada hababka qaboojinta ee aad bixiso?
J: Inta badan waxaanu bixinaaONAN (Oil Dabiiciga Hawada Dabiiciga ah)ama qaboojinta KNAN ee tiirka - Buurta beddelka qaybinta
Blogs la xiriira
Ku hel Xigashada Transformer-ka Ku Dulsan 24 Saac gudahood
Noo sheeg danabkaaga & shuruudahaaga awooda - injineeradayadu waxay ku jawaabi doonaan xal habaysan.

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha hormuudka ah iyo alaab-qeybiyeyaal koronto ku dhejisan tiirarka ee Shiinaha. Waxaan si diiran kuugu soo dhawaynaynaa inaad ka iibsatid kharashka{2} Haddii aad hayso wax su'aalo ah oo ku saabsan xigashada ama jaantusyada, fadlan xor u noqo inaad noo soo dirto iimayl.