wmpage167-page5-img1.webp
wmpage167-page5-img4.webp
wmpage167-page5-img5.webp
wmpage167-page5-img5.webp
wmpage167-page5-img5.webp
wmpage167-page5-img5.webp
wmpage167-page5-img5.webp
wmpage167-page5-img5.webp

 

 

SCOTECH Transformer Solutions for Global Power Industry

 

Sida soo saaraha taangiyada beddelka ee la isku halayn karo, SCOTECH waxay siisaa taangiyada beddelka ee caadiga ah soosaarayaasha, qandaraaslayaasha guud ee EPC, shirkadaha dayactirka, iyo shirkadaha tamarta adduunka oo dhan.
Haddii loogu talagalayTirka -Ku-bedelayaasha Ku rakiban, suuf {{0}Ku rakiban Transformers, Qaybinta Transformers, Transformers Poweramatransformers gaar ahwaxaan haynaa xalalka taangiyada saxda ah.
• Nakhshad gaar ah oo loogu talagalay dhammaan noocyada beddelka
• Si buuxda loo shaabadeeyey, daadsan - taangiyada aan caddayn
• Superior corrosion protection (>Tijaabada buufinta milixda 1000h)
U hoggaansan IEEE / IEC / CSA/ANSI iyo heerarka kale ee caalamiga ah

 

Codso Xigashooyinka Haamahaaga Gaarka ah

 

 

Noocyada Haamaha Transformer-ka ee aan Soo saarno

 

Waxaan u soo saareynaa taangiyada beddelka ee caadiga ah ee noocyada rakibaadda kala duwan iyo qiimeynta awoodda, la kulanka IEEE / IEC

heerarka iyo shuruudaha OEM.

 

Taangiga loogu talagalay Transformer-ka tiirarka

Naqshadeeyay hal - tiir weji ah oo ku rakiban transformers, oo ku habboon nidaamyada qaybinta dusha sare ee dibadda.
Qiimaynta lagu dabaqi karo:Ilaa 1000 kVA
Heerka Korantada:Ilaa 34.5kV
• Qaab dhismeedka haanta:Daadin-Cayn, naqshada haanta saliidda si buuxda loo shaabadeeyey
U Hogaansanaanta Heerka:IEEE, IEC, ANSI, CSA, NEMA, iyo heerarka DOE

Haanta loogu talagalay beddelka suufka keliya ee ku rakiban

Loo isticmaalo nidaamka qaybinta awooda dhulka hoostiisa iyo deegaanka oo leh qaab dhismeed is haysta iyo ilaalinta daxalka.
Qiimaynta lagu dabaqi karo:Ilaa 250 KVA
Heerka Korantada:Ilaa 34.5 KV
Naqshadaynta Badbaadada:Tamper- Qaab dhismeedka taangiga iska caabinta
U Hogaansanaanta Heerka:IEEE, ANSI, CSA, NEMA, iyo heerarka DOE.

Taangiga Saddexda Waji ee suufka Ku rakiban Transformer

Taangiyada taangiyada culculus-oo loogu talagalay saddex{1}}wajile suuf ah oo ku rakiban transformers ee barnaamijyada ganacsiga iyo warshadaha.
Qiimaynta lagu dabaqi karo:Ilaa 10000 KVA
Heerka Korantada:Ilaa 46 kV
• Dhamaystirka & Ilaalinta Daxalka:kulul{0}}dhamays galvanized ah ama bir buuxda
U Hogaansanaanta Heerka:IEEE / ANSI / CSA/DOE/NEMA

Haanta Qaybinta iyo Korontada

Haamaha beddelka macaamiisha ee qaybinta iyo korontada, ku habboon saldhigyada hoose iyo mashaariicda tamarta.
Qiimaynta Transformer:ilaa 500 MVA
Heerka Korantada:ilaa 330kV
• Bandhig faneedka haanta:> 1000 saacadood tijaabada buufinta milixda
U Hogaansanaanta Heerka:IEC 60076 / IEEE C57 / CSA/ ANSI

 

 

 

Maxaa Haamaha Shidaalka Transformer-ka Loo Aaminsan Yahay

Injineerka ilaa Heerarka Caalamiga ah

Dhammaan taangiyada saliidda beddelka waxaa loogu talagalay inay la kulmaan IEC, IEEE, CSA iyo heerarka kale ee loo baahan yahay, hubinta waxqabadka la isku halayn karo iyo u hoggaansanaanta shuruudaha adag ee korantada iyo farsamada ee Yurub iyo Waqooyiga Ameerika.

Si Buuxda Loogu Habayn Karo Baahidaada

Waxaan u soo saareynaa taangiyada beddelka si adag iyadoo loo eegayo sawiradaada, qeexidaada, iyo shuruudaha mashruuca.

Alxanka Sarreysa & Diidashada -Naqshadda caddaynta

Farsamooyinka alxankayaga horumarsan, oo ay weheliso cadaadis adag iyo tijaabinta daadinta, waxay dammaanad qaadayaan{0}saliid muddada dheer{1}} adkaynta iyo hufnaanta qaabdhismeedka ee xaaladaha adag.

Ka-hortagga {{0}Daawaynta Dusha Daxalka

Laga soo bilaabo kulul - galvanization-ka kulul ilaa korantada lagu buufiyo budada polyesterka, koofiyadaha poliurethane, iyo ikhtiyaarada birta ah, waxaanu taangiyadaada ka ilaalinaa bay'ada adag ee dibadda waxaana aanu hubinaynaa cimri waarta.

Sare-Ikhtiyaarada agab tayo leh

Taangiyada wax beddelka ahi waxay isticmaashaa birta kaarboonka, birta aan la taaban karin, ama kaarboon{0}}isku-dhafka birta aan-qabow Ikhtiyaarada birta aan fiicnayn waxaa ka mid ah 409 iyo 304L, hubinta iska caabbinta daxalka wanaagsan ee haanta.

Waxqabadka Kulaylka La Habeeyay

Taangiyada saliidda beddelka waxay ka faa'iidaystaan ​​hiitarka galvanized ama ahama ama naqshadaynta haanta qaboojinta si kor loogu qaado waxtarka kulaylka loona hubiyo heerkulka saliidda deggan ee xaaladaha shaqada ee joogtada ah.

 

 

 

Codsiyada

Tank For Pole Mounted Transformer

Taangiga loogu talagalay Transformer-ka tiirarka

Loo isticmaalo hal {{0}Transformers qaybinta weji oo ku rakiban tiirarka tamarta, oo inta badan laga helo xadhkaha korantada ee dusha sare ee sahayda guryaha iyo ganacsiga ee magaalooyinka iyo miyiga.

Tank For Single Phase Pad Mounted Transformer

Haanta loogu talagalay beddelka suufka keliya ee ku rakiban

Lagu dabaqay hababka qaybinta dhulka hoostiisa ee tamarta deegaanka ee meelaha sida xaafadaha, jidadka, iyo horumarinta miyiga, oo bixisa dhul kooban oo sugan-heerka heerka

Tank For Three Phase Pad Mounted Transformer

Taangiga Saddexda Waji ee suufka Ku rakiban Transformer

Laga dalbado ganacsiga, warshadaha, iyo kuwa waaweyn{{0}degmooyinka la dego ee baaxada leh ee dhulka{1}kusalaysan saddex{2}}qaybinta korantada. Taangiyadani waxay bixiyaan ilaalinta deegaanka iyo qaboojinta la isku halayn karo oo loogu talagalay transformers-ka keena suuqyada wax iibsiga, warshadaha, iyo -horumarka macaamiisha.

Tank For Distribution

Haanta Qaybinta
Transformer

Loogu talagalay transformers-ka loo isticmaalo talaabadii ugu danbaysay ee isbadalka tamarta ee nidaamka awood qaybinta, gaadhsiinta korontadu si toos ah ilaa dhamaadka- isticmaalayaasha guryaha, ganacsiga, iyo goobaha warshadaha fudud.

Tank For Power

Taangiga Awoodda
Transformer

Looga faa'iidaysto - gudbinta korantada ee sare iyo soo dhawaynta warshada korontada iyo saldhigyada, fududaynta gudbinta korantada fog{1} iyo isku xidhka xidhidhka

Tank For Special

Taangiga gaarka ah
Transformer

Lagu farsameeyay transformers ee codsiyada warshadaha gaarka ah iyo bay'ada qallafsan, sida biraha (hagaajinta/foornada), macdanta, gaadiidka tareenka, beeraha dabaysha ee xeebaha, iyo mashaariic kale oo gaar ah.

 

 

Ma u baahan tahay Xalka Haamaha Transformer ee la isku halayn karo oo la Habeeyay?

Noo soo dir sawiradaada ama qeexitaannadaada farsamo si aad u soo xigasho degdeg ah.

 

 

 

Maxaad Noogu Dooranaysaa Sameeyaha Haamaha Transformerkaaga

 

Waxaan nahay shirkad soo saarta taangiyada transformer-ka oo khibrad sannado ah u leh naqshadaynta iyo samaynta tayada sare-

saliid - taangiyada beddelka ka buuxo Khibraddeenu waxay dabooshaa tiirka ku dheggan, suufka -ku dhejiyay, qaybinta, iyo korontaddelayaasha,

waxaanan taageernaa OEM iyo naqshadaha gaarka ah labadaba si aan u daboolno shuruudaha mashruucaaga.

Gudaha -Wax soosaarka Haamaha Transformer

Dhammaan taangiyada transformer-ka waxa lagu soo saaray gabi ahaan -guriga, iyada oo hubinaysa in si buuxda loo xakameeyo tayada iyo saxnaanta.
• Goynta saxanka birta iyo samaynta iyadoo la adeegsanayo mashiinnada foorarsiga ee CNC ee horumarsan
alxanka tooska ah iyo gacanta ee ay sameeyaan alxanayaal shahaado haysta oo loogu talagalay kala-goysyada muhiimka ah
• Baadhitaanka cabbirka iyo cadaadiska/baaritaanka dheecaanka ka hor dhalmada

Qalabka alxanka sare & Samaynta

Warshadayadu waxa ay ku qalabaysan tahay{0}}ee{1}}-qalabka fanka si loo hubiyo tayada dhisme sare:
• CNC foorarsi iyo -mashiinnada samaynta waajibaadyada si sax ah loo sameeyo
• Nidaamyada alxanka tooska ah ee tayada alxanka joogtada ah
• Alxanleyaasha khibradda leh iyo kuwa la shahaadiyey ee alxanka muhiimka ah ee buuxinaya shuruudaha farsamada iyo xidhitaanka

Xakamaynta Tayada Adag & Tijaabinta Liiqsiga

Waxaan dabaqnaa hababka xakamaynta tayada adag si loo hubiyo in haan kasta ay buuxiso heerarka ugu sarreeya:
• Kormeer cabbir oo dhammaystiran ee isu-ururinta saxda ah
• Hubinta tayada alxanka iyadoo loo eegayo shahaadooyinka warshadaha
• Cadaadiska iyo tijaabinta daadinta si loo dammaanad qaado badbaado iyo la isku halayn karo - hawlgal wakhti dheer ah

Daaweynta Dusha sare & Ilaalinta Daxalka

Rakibaadaha beddelka dibadda waxay dalbanayaan iska caabin sare oo daxalka. Waxaanu bixinaa daawayn badan oo dusha sare ah si aanu u dheerayno nolosha adeega deegaan adag:
• Kulul -Dhib galvanizing si ay u adkaysato daxalka ugu badan
• Rinjiyeynta warshadaha ee dahaarka ilaalinta
Dahaarka budada ah -dhamaystir waara oo soo jiidasho leh

 

 

 

Awoodaha Soo saarista Haamaha Saliida Transformer

  • Aqoon-is-weydaarsiga Farsamaynta Haamaha Shidaalka
  • Habka Soo Saarka Haamaha Shidaalka Transformer
  • Haamaha Saliida Transformer-ka ee Dhammaatay
  • 1
    2
    3
    4
    5
    6
    7
    8
    9
  • Steel Plate Cutting

    Goynta Saxanka Birta

    Drilling

    qodista

    Bending and Forming

    Laabashada iyo Samaynta

    Fuel Tank Rounding

    Wareegida Haamaha Shidaalka

    Welding

    alxanka

    Grinding and Polishing

    Shiidida iyo Tooshka

    Surface Treatment

    Daaweynta Dusha sare

    Quality Testing

    Tijaabinta Tayada

    Export Packaging

    Baakadaha Dhoofinta

  • 1
    2
    3
    4
    5
    6
    7
    8
    9

 

 

FAQ

 

S: Miyaad soo saari kartaa taangiyada isbeddelka sida ku cad sawiradayada?

J: Haa. Waxaan ku takhasusay taangiyada beddelka ee gaarka ah iyadoo ku saleysan sawirada macaamiisha iyo qeexitaannada farsamada.

S: Sideen ku helnaa xigasho?

J: Kaliya noo soo dir sawiradaada, qeexitaannadaada, ama shuruudaha aasaasiga ah, kooxdayada injineernimada ayaa si dhakhso ah uga jawaabi doona.

S: Ma bixisaa taageero farsamo ka dib dhalmada?

J: Haa. Kooxdayada injineernimada waxay siisaa taageerada rakibaadda, dayactirka, iyo cilad-baadhista si loo hubiyo isku halaynta muddada dheer{1}.

S: Taangiyada ma loo dejiyay badbaado?

J: Haa. Dhammaan taangiyada beddelka korantada waxaa loogu talagalay in lagu dhejiyo ikhtiyaarro isku dhafan si loo hubiyo badbaadada korantada inta lagu jiro hawlgalka.

S: Taangiyadu ma xamili karaan rakibaadda bannaanka ee meelaha adag?

J: Haa. Taangiyadayada waxaa loogu talagalay xaaladaha dibadda, oo leh {{1} dahaarka tayada sare leh, xoojinta qaab dhismeedka, iyo dhulka isku dhafan si loo hubiyo adkeysiga iyo badbaadada.

S: Waa maxay fursadaha ilaalinta daxalka ee aad bixiso?

A: We provide multiple corrosion protection methods: stainless steel, hot-dip galvanization, polyester powder coating, and polyurethane topcoats. Most options achieve >1000 saacadood iska caabin ah buufin milix ah.

S: Taangiyada transformerkaagu ma daadsan yihiin{0}} caddayn?

J: Haa. Dhammaan taangiyada si adag ayaa loo cadaadiyey{1}}waa la tijaabiyey oo la alxameeyey iyadoo la isticmaalayo farsamooyin horumarsan si loo hubiyo -saliid muddada dheer{3}} adkaynta iyo sharafta qaabdhismeedka.

 

 

 

Blogs la xiriira

 

 

 

image

Ka hel Xigasho ku saabsan Nakhshad Taangiyada Transformer

 
 

 

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soo saarayaasha ugu horreeya iyo alaab-qeybiyeyaasha taangiga transformer ee Shiinaha. Waxaan si diiran kuugu soo dhawaynaynaa inaad ka iibsatid kharash{2}taangiga transformer-ka hufan ee iibka ah halkan warshadeena. Haddii aad hayso wax su'aalo ah oo ku saabsan xigashada ama jaantusyada, fadlan xor u noqo inaad noo soo dirto iimayl.