Hal weji furaha ah ee lagu rakibay

Scotech waxay bixisaa gogol wejiga oo keliya ee loo yaqaan 'pad' oo lagu rakibay illaa 167 kVa 34.5 kv

La xiriir iibka
  • Bandhig
  • Duqo
Soo saarid
Hal weji furaha ah ee lagu rakibay
Illaa 167 kVa 34.5 kv
Scotech Scorcher Secunta Purner Purnerformer wuxuu qaadanayaa naqshad laba koranta ah waxayna u baahan tahay adeegsiga badalka korantada ee laba korantada ee loo beddelo korantada. Naqshadeyntaani waxay xaqiijineysaa in beddelka uu la qabsan karo baahiyaha awooda kaladuwan, sidaasna ay ku fiicnaato wax ku oolnimada iyo laqabsashada. Waxaa si weyn loogu isticmaalaa meelaha la deggan yahay, xarumaha ganacsiga, isbitaalada, jardiinooyinka, iskuulada, iwm.
Soo dejiso qoraalka yar
productcate-1-1
Faa'iidooyinka
  • Dheer
  • Bilaash
    Dayac-tir
  • Hawo sare
    Waxqabad fiicni
  • Amni
    Astaamaha
Astaamaha
productcate-1-1

Cayimid

  • Heerarka loo habeeyay sida Ieee
  • Awoodda lagu qiimeeyay10KVA ilaa 167 MVA
  • Heerka dahaarka ee lagu qiimeeyay ilaa 34.5 kv
  • Waxaa lagu qiimeeyay soo noqnoqoshada 50 ama 60 hz
  • Qalabka dabaysha waa naxaas
  • Qalabka asaasiga ah ayaa ah mid ku jihaysan xaashida steel silicon
  • Fasalka kuleylka kuleylkaH
  • Caabbinta heerarka huurka badan>95%
  • Si dabiici ah loo qaboojiyey (a) ama hawada lagu qasbay (af) codsi
  • Rakibaadda gudaha ama dibedda ee codsiga (oo leh xirmo ilaa IP44)
  • Shaqada dulsaarka (OLTC) codsi gaar ah
  • Xadgudubka caqabadda ayaa ah0.5% ~ 10%
Qoraal ka warbixineya

 

 

 

 

167 kVA Pad Mount Transformer-24*12/0.24 kV|Jamaica 2024
167 kVA Pad Mount Transformer-24*12/0.24 kV|Jamaica 2024
Dalka: Jamaica 2024
Awoodda: 167kVA
Voltage: 24/13.8-0.24kV
Feature: dual-qalab dooraha danab
100 kVA Pad Mount Transformer-24/0.24 kV|Jamaica 2024
100 kVA Pad Mount Transformer-24/0.24 kV|Jamaica 2024
Dalka: Jamaica 2024
Awoodda: 100kVA
Voltage: 24/0.24kV
Feature: oo leh xire qalliin
50 kVA Hal Waji oo Waji ah oo Ku rakiban Badaha-24/0.24 kV|Jamaica 2024
50 kVA Hal Waji oo Waji ah oo Ku rakiban Badaha-24/0.24 kV|Jamaica 2024
Dalka la geynayo: Jamaica 2024
Awoodda: 50kVA
Voltage: 24GrdY/13.8-0.24/0.12 kV
Muuqaal: Qabta qalliin
50 kVA suuf Ku rakiban Beddelka-24.94/0.24*0.12 kV|Sacuudi Carabiya 2024
50 kVA suuf Ku rakiban Beddelka-24.94/0.24*0.12 kV|Sacuudi Carabiya 2024
Dalka: Sacuudi Carabiya 2024
Awoodda: 50kVA
Voltage: 24.94/0.24kV
Feature: haanta birta ah ee aan lahayn
50 kVA Waji Keliya ah oo Ku Rakiban Badal Qaybinta Qaybinta-24*12/0.24 kV|Jamaica 2024
50 kVA Waji Keliya ah oo Ku Rakiban Badal Qaybinta Qaybinta-24*12/0.24 kV|Jam...
Dalka: Jamaica 2024
Awoodda: 50kVA
Voltage: 24 * 12-0.24 / 0.12kV
Feature: oo leh laba danab hoose
25 kVA suuf Ku rakiban Beddelka-24*12/0.24 kV|Jamaica 2024
25 kVA suuf Ku rakiban Beddelka-24*12/0.24 kV|Jamaica 2024
Dalka la geynayo: Jamaica 2024
Awoodda: 25kVA
Voltage: 24GrdY/13.8*12GrdY/6.9-0.24/0.12kV
Feature: Laba danab hoose
225 KVA Hal Weji Beddelka-4.8/0.12/0.24 KV|Kanada 2025
225 KVA Hal Weji Beddelka-4.8/0.12/0.24 KV|Kanada 2025
Dalka: Kanada 2025
Awoodda: 225 kVA
Voltage: 8.32GrdY/4.8-0.12/0.24kV
Muuqaalka: oo wata furaha Kirk
37.5 KVA Hal Waji-Badelayare-23.9/0.24 KV|Jamaica 2025
37.5 KVA Hal Waji-Badelayare-23.9/0.24 KV|Jamaica 2025
Dalka: Jamaica 2025
Awoodda: 37.5 kVA
Voltage: 24-0.24 / 0.12kV
Feature: oo leh IFD
100 KVA Korontada Beddelka-7.2/0.12*0.24 KV|Kanada 2025
100 KVA Korontada Beddelka-7.2/0.12*0.24 KV|Kanada 2025
Dalka: Kanada 2025
Awoodda: 100 kVA
Voltage: 12.47GRDY/7.2-0.24/0.12 kV
Feature: Shuruudaha khasaaraha gaarka ah