2660 KVA Bannaanka Beddelka Sanduuqa-22.8 / 0.8 KV|USA 2025

2660 KVA Bannaanka Beddelka Sanduuqa-22.8 / 0.8 KV|USA 2025

Dalka la geynayo: Ameerika 2025
Awoodda: 2660kVA
Voltage: 22.8/0.8 kV
Tilmaam: Hufnaanta DOE oo leh baararka naxaasta
U dir sooji

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha 2660 kva ugu kalsoonida badan USA 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. nala soo xidhiidh wixii faahfaahin ah

 

2660 kva outdoor transformer box-front-door-open

Sanduuqa beddelka bannaanka oo keenaya badbaado, la isku halayn karo, iyo dhexdhexaad hufan-qaybinta korantada tamarta casriga ah iyo shabakadaha warshadaha.

 

01 Guud

1.1 Sharaxaada Mashruuca

2025, macmiil Maraykan ah ayaa dalbaday a2660 kVA saddex weji suuf ku rakiban transformer, loogu talagalay in lagu rakibo dhex dhexaadiyaha korantada qaybinta shabkada wax ka beddelka ee gudaha Maraykanka, halkaas oo isku halaynta, badbaadada, iyo muddada dheer{0}}waxqabadka hawlgelinta ay lama huraan u ahaayeen kaabayaasha tamarta mashruuca. Transformer-ku wuxuu u shaqeeyaa sidii sanduuqa beddelka, isku-darka taangiga beddelka, qalabka beddelka, aaladaha ilaalinta, iyo qaybaha isku xirka korontadu waxay ku dhexjiraan suuf kooban - xero dhejis ah oo ku habboon shabakadaha qaybinta tamarta iyo deegaanka warshadaha. Intaa waxa dheer, iyada oo qayb ka ah isla dalabka, macmiilku waxa uu soo iibiyay mid ka yar150 kVA suuf ku rakiban transformersi loo keeno culaysyo caawiye ah oo ku dhex jira nidaamka korontada ee mashruuca.

Cutubka waxa lagu qiimeeyay 2660 kVA, oo leh danab hoose oo ah 22.8 kV iyo danab labaad oo ah 0.8 kV, waxaanay adeegsataa kooxda YNd1 vector, taas oo taageerta saddex - isbeddelka korantada ee wejiga; barokaca wajiga saxda ah iyo sifooyinka dhulka ayaa la ilaaliyaa, sida looga baahan yahay nidaamyada qaybinta korantada dhexdhexaadka ah. Isku xidhkani waxa uu hoos u dhigayaa dhexdhexaadinta tamarta -koronta voltajiga si hufan, iyada oo la keenayo danab joogto ah culaysyada korantada ee hoose{7}}laisku halayn karo, xasiloon, oo diyaar u ah is dhexgalka shabakada

Naqshadeynta iyo soo saarista si waafaqsan IEEE Std C57.12.34-2022, Transformer-ku wuxuu u hoggaansamaa heerarka Waqooyiga Ameerika ee qalabka beddelka dhejiska ah, hubinta hawlgalka badbaadada ee nidaamyada qaybinta dhulka hoostiisa iyo rakibaadda dibadda halkaasoo soo-gaadhista deegaanka iyo badbaadada hawlgalka ay tahay in si taxadar leh loo xakameeyo.

 

 

 

1.2 Tilmaamaha Farsamada

2660kVA saddex waji oo suuf ah oo ku rakiban tafatirka tafatirka iyo xaashida xogta

loo geeyey
Ameerika
Sannadka
2025
Nooca
Saddex weji suuf Buur Transformer
Heerka
IEEE Std C57.12.34-2022
Awood lagu qiimeeyay
2660KVA
Soo noqnoqda
60HZ
Quudinta
Loop
Hore
dhintay
Marxaladda
saddex
Nooca qaboojinta
KNAN
Insulant dareere ah
FR3 Saliid
Korantada aasaasiga ah
22.8 kV
Voltage Secondary
0.8 kV
Kooxda Vector
YNd1
Qalabka dabaysha
Aluminium
Caqabada
5.75%
Waxtarka
DOE
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
2.5 kV
Load Lumista
16.5kV
Agabka
Gaashaanka dhulka

 

1.3 Sawirro

2660kVA saddex weji oo suuf ah oo ku rakiban sawir beddele iyo saxan magaceed

2660 kva outdoor transformer box-engineering-drawing 2660 kva outdoor transformer box-nameplate

 

 

02 Wax-soo-saarka

2.1 Haanta iyo Xerada

2660 kva outdoor transformer box-oil tank

suufka - taangiga is beddelka ku rakiban yahay waa mid si buuxda alxanka leh, qaab-dhismeed xidhan, oo loo dhisay inuu ahaado mid waara oo fara-maroojis - adkaysi u yeesha, ku habboon rakibaadda dibadda Albaabada waxa lagu xidhay boolal penta ah iyo 3 - qufulka qufulka dhibcaha; dhamaystirka cad ee budada-dahaarka leh (RAL 9003) waxay bixisaa iska caabbinta deegaanka, daxalka, iyo xaalufka UV.

 

2.2 Nidaamka Dahaarka

Transformer-ku wuxuu shaqeeyaa FR3 dareeraha dahaadhka ester-ka dabiiciga ah. Dabaylaha aasaasiga ah iyo kan sareba waa aluminium waxayna ku dahaaran yihiin inay u adkaystaan ​​labada weji{2}}ilaa{3}} wejiga iyo wejiga{4}}ilaa- culayska tamarta dhulka. Intaa waxa dheer, unuggu waxa uu leeyahay gaashaan koronto oo salka ku haya inta u dhaxaysa dabaylaha hoose iyo kuwa sare, kaas oo yaraynaya faragelinta sare ee -iyo korontadu

2660 kva outdoor transformer box-transformer-windings

 

 

03 Nidaamka Kormeerka iyo Ilaalinta

3.1 Ilaalinta iyo Kormeerka Korontada

2660 kVA outdoor transformer box standard Monitoring & Protection Accessories

Si loo hubiyo hawlgal badbaado leh oo la isku halayn karo, Transformer-ka qaybinta korantada dhexdhexaadka ah wuxuu ku qalabaysan yahay ilaalin badan iyo qaybo ilaalin oo isku dhafan gudaha sanduuqa beddelka ee dibadda. Tilmaamaha muhiimka ah waxaa ka mid ah:

• Gaashaanka korantada ee dhulka
• Heerka saliidda, heerkulka saliidda, iyo cabbirrada cadaadiska haanta
• Waalka gargaarka cadaadiska ee ilaalinta cadaadiska xad-dhaafka ah
• Qabqablayaasha qallafsan
• Baararka naxaasta ee lagu xidho fiyuusyada dibadda
• Raad damiyada jebiya

Qalabka

Shaqada

Qiyaasta Heerka Saliida

Wuxuu la socdaa heerka saliidda dahaarka

Qiyaasta Heerkulka Saliidda

Waxay la socdaan heerkulka shaqaynta beddelka

Cabbirka Cadaadiska Haamaha

Wuxuu ogaadaa isbeddelada cadaadiska gudaha

Valve Relief Cadaadis

Waxay ka ilaalisaa cadaadiska gudaha ee xad-dhaafka ah

Qalabkan kormeerka ah ayaa bixiya muuqaal hawleed joogto ah, taas oo u oggolaanaysa kooxaha dayactirka inay aqoonsadaan arrimaha suurtagalka ah ka hor intaanay u xuubsiiban guuldarrooyinka hawlgalka. Ka-hortagga la socodka waxa ay xoojisaa isku halaynta waxayna xaqiijisaa{1} xasiloonida muddada dheer ee shabakadaha beddelka qaybinta tamarta dhexe. Intaa waxaa dheer, hawl-wadeennadu waxay si degdeg ah uga falcelin karaan xaaladaha aan caadiga ahayn, iyagoo yaraynaya wakhtiga dhimista.

 

3.2 Bedelida iyo Qaybaha Ilaalinta

Transformer-ku waxa uu taageeraa isuduwidda macmiilka{0}}Aaladaha ilaalinta dibadeed ee la keenay, oo ay ku jirto Eaton Bussmann High{1}}Speed ​​Fuse 170M, loogu talagalay in lagu bixiyo jawaab degdeg ah khaladaadka korantada. Unugga waxaa ka mid ah:

• Saddex laba - boos jebinta daaranadaha
• Baararka naxaasta ee isku xirka fiyuuska
• Qab-qablayaasha sare ee hillaaca iyo ilaalinta qulqulka

2660 kVA outdoor transformer box Eaton Bussmann High-Speed Fuse 170M series

Habayntani waxa ay u ogolanaysaa saddaxda weji ee ku rakiban transformer-ka in ay si badbaado leh u go'doomiyaan khaladaadka korantada iyada oo la ilaalinayo sii socoshada inta ka hadhay shabakada qaybinta. Beddelka iyo ilaalinta la isku dubariday waxay xaqiijisaa jawaabta khaladka degdega ah, ilaalinta nidaamka la isku halayn karo, iyo soo gudbinta tamarta aan kala go'a lahayn, taasoo ka dhigaysa sanduuqa wax beddelka ee dibadda mid aad ugu habboon isticmaalka-miisaanka iyo codsiyada PV qoraxda.

 

 

04 Tijaabinta

2660 kVA outdoor transformer box testing standards

Natiijooyinka Imtixaanka

2660 kVA outdoor transformer box  Test Results

2660 kva outdoor transformer box-factory-test
2660 kva outdoor transformer box-performance-test

 

 

05 Baakadaha iyo gaadiidka

2660 kva outdoor transformer box-export-packing
2660 kva outdoor transformer box-shipment

 

 

06 Codsiyada Caadiga ah

Sida sanduuqa beddelka dibadda, transformer-kan suufka ku rakiban waxaa loogu talagalay in lagu rakibo jawi kala duwan oo koronto dhexdhexaad ah, oo ay ku jiraan nidaamyada korantada warshadaha, kaabayaasha tamarta, tas-hiilaadka tamarta dib loo cusboonaysiin karo, iyo shabakadaha qaybinta ganacsiga halka loo baahan yahay rakibaadda beddelka dibadda ee badbaado leh.

Codsiyada caadiga ah waxaa ka mid ah:
• Utility dhexdhexaad ah -Nidaamka qaybinta danab
Qaybinta tamarta warshadaha
• Tas-hiilaadka tamarta la cusboonaysiin karo, oo ay ku jiraan beeraha PV cadceedda
• Kaabayaasha dhaqaalaha iyo mashaariicda ganacsiga
Deegaannadan, Transformer-ku wuxuu bixiyaa beddelaad danab hufan leh iyadoo la ilaalinayo isku hallaynta sare ee hawlgalka, sidoo kale awood u siinaysa is-dhexgalka fudud ee qalabka beddelka ee qalabka korantada.

 

 

07 Goobta iyo Kooban

2660 kva outdoor transformer box-right-45-degree-view

Guud ahaan kaabayaasha korantada ee mashruuca dhexdiisa, 2660 kVA Transformer-ka dibadda waxa uu u adeegaa sida transformer-ka qaybinta korantada dhexe ee dhexe, u rogaya dhexdhexaadiyaha tamarta{1}}awoodda korantada ee heerka korantada ee la isticmaali karo ee nidaamyada korantada ee hoose iyada oo la hubinayo in ay badbaado iyo xasilooni ku shaqeyso iyada oo loo marayo IEEE-naqshadeeda waafaqsan, nidaamka dahaarka FR3, iyo qalabka ilaalinta isku dhafan. Transformer-ku wuxuu sameeyaa unugga beddelka awoodda dhexe ee shabakadda qaybinta mashruuca, sidoo kale wuxuu la shaqeynayaa isuduwidda 150 kVA kaaliyaha koronto ee sanduuqa korantada si loo hubiyo in la isku halayn karo, koronto joogto ah.

 

 

Hot Tags: sanduuqa transformer dibadda, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha

U dir sooji