100 MVA Transformers Large Power-132/22 KV|Australia 2025

100 MVA Transformers Large Power-132/22 KV|Australia 2025

Dalka la geynayo: Australia 2025
Awoodda: 100000kVA
Voltage: 132/22KV
Astaanta: Naqshad Caqabad Sare: 34 %
U dir sooji

Jiangshan Scotech Electrical Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha 100 mva ugu kalsoonida badan -132/22 kv|Australia 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

 

100mva-132kv-22kv-data-center-power-transformer in workshop

Transformers koronto waaweyn oo la isku halleyn karo oo loogu talagalay nidaamyada xogta xarunta xogta deggan oo hufan.

 

 

01 Guud

1.1 Sharaxaada Mashruuca

Mashruucani wuxuu ku lug leeyahay keenista a100 MVA koronto weyn, oo loo qaabeeyey qayb ka mid ah - nidaamka tamarta xarunta xogta ee sare ee Malaysia. Waxay calaamad u tahay cutubka labaad ee nooca koronto-dhaliyeyaasha waaweyn ah ee la siiyo isla macmiilka, ka dib markii si guul leh loo hirgeliyocutubka ugu horeeya ee 2023.

Nidaamku wuxuu ka tarjumayaa kalsoonida xooggan ee waxqabadka, isku hallaynta, iyo tayada injineernimada ee koronto-sameeyayaasha waaweyn, gaar ahaan codsiyada kaabayaasha muhiimka ah halkaas oo hawlgal joogto ah ay lama huraan tahay.

Transformer-ku waa unug muhiim ah oo lagu qiimeeyay 132/22 kV oo leh koox YNd1 vector ah, oo leh laba awoodood oo ah 70/100 MVA (ONAN/ONAF), taas oo u ogolaanaysa hawl qabad dabacsan iyadoo lagu jiro xaalado kala duwan oo culeys - shay gaar ahaan muhiim u ah transformers-ka waaweyn ee lagu isticmaalo xarumaha xogta.

Nakhshad heersare ah oo 34% ah, oo si aad ah uga saraysa heerarka caadiga ah, waxa ay wanaajisaa xaddidaadda hadda jirta iyo xasilloonida nidaamka, taas oo ka dhigaysa cutubkan mid ku habboon xasaasiga iyo degaannada rarka sarreeya-

Ku qalabaysan nidaamka korjoogteynta iyo ilaalinta - oo ay ku jiraan fiber{1} cabbirka heerkulka dabaylaha indhaha, faakuum OLTC, iyo is{2}}dib u dejinta qaraxa{3}}alaadaha cadaymaha-Transformer-kan wayn waxa uu xaqiijiyaa hawlgal xasiloon oo badbaado leh oo hoos yimaada xaaladaha kulaylaha (celcelis ahaan 28 darajo, heerka ugu sarreeya 33 digrii, 00%) ilaa huurka.

Sifooyinka dheeriga ah waxaa ka mid ah RIP engegan{0}}nooca bushings, hoose{1}}Naqshadda qaylada (In ka yar ama la mid ah 85 dB(A)), hufnaanta sare (99.68%, PEI Level 2), iyo saddex-column CRGO silicon steel core. Iyada oo miisaankeedu yahay ku dhawaad ​​155 tan iyo cabbirada ka badan 9 × 7 × 6 mitir, waxay ka dhigan tahay tusaale ahaan tusaale ahaan taransfoorayaasha awooda waaweyn ee casriga ah oo loogu talagaly isku halaynta sare iyo codsiyada waajibaadka culus{11}

Mashruucani waxa uu si dheeraad ah u muujinayaa awooda lagu bixiyo {{0}waxqabad sare oo koronto ah oo loogu talagalay shabakadaha awooda xogta xarunta.

 

 

1.2 Tilmaamaha Farsamada

100MVA Tilmaamaha Beddelka Awoodda Weyn iyo xaashida xogta

loo geeyey
Australia
Sannadka
2025
Nooca
Transformer-ka ugu muhiimsan
Heerka
IEC 60076
Awood lagu qiimeeyay
100 MVA
Soo noqnoqda
50HZ
Marxaladda
saddex
Nooca qaboojinta
ONAN/ONAF
Insulant dareere ah
25 # PCB -saliid macdanta bilaashka ah
Korantada aasaasiga ah
132 kV
Voltage Secondary
22 kV
Kooxda Vector
YNd1
Qalabka Muhiimka ah
Hadhuudh duuban qabow oo jihaysan
Qalabka dabaysha
Copper
Caqabada
34.0% oo leh dulqaadka +/- 7.5%
Heerka Awooda Codka ugu badan
In ka yar ama la mid ah 85 dB(A)
Waxtarka a
99.68%
Taabo Beddelka
OLTC
Riixista Range
+10.5% ilaa -25.5%.
Waxtarka Tamarta
IEC 60076-20, PEI 2 (ugu yar)
Wax Xamuul ah ma jiro
In ka yar ama la mid ah 43 kW
Load Lumista
In ka yar ama la mid ah 510 kW
Agabka
Habaynta caadiga ah

 

 

1.3 Sawirro

100MVA Sawirka beddelka Korontada Weyn iyo saxanka magaca

100mva-132kv-22kv-data-center-power-transformer-dimension-drawing 100mva-132kv-22kv-data-center-power-transformer-nameplate

 

 

02 Wax-soo-saarka

2.1 Core

Saddexda - xudunta udubdhexaadka ah waxay qaataan saddex - qaab dhismeedka (3- addin), oo ah qaab dhismeedka awooda waaweyn ee u baahan daacadnimo farsamo oo xoogan. Labada addimada xudunta u ah iyo harqoodyadaba si adag ayaa loo xaqiijiyaa iyadoo la isticmaalayo xariijimaha birta ah ee isku xidha halkii ay ka ahaan lahaayeen isku xidhka xidhidhiyaha, hubinta awooda farsamaysan ee lebbiska ah iyo gariir yaraanta. Xuddunta waxay ka samaysan tahay qabow{6} hadhuudh duuban - bir silikoon ku jihaysan oo leh sifooyin birlabeed aad u wanaagsan, taasoo keentay khasaare aad u hooseeya iyo hadda oo aan culays lahayn oo aad u hooseeya oo keliya 0.1%. Dahaarka dahaadhka waa warqad dahaaran oo dhumucdiisu tahay 0.95 s.

100mva-power-transformer three-limb iron core
100mva-transformer-grain-oriented-silicon-steel-transformer-core

 

2.2 Dabaylaha

Habaynta dabayshu waxay raacdaa taxanaha L/H/T, oo ka dhigan Voltage Low, Voltage High, iyo Tapping dabaylaha. Nooca dabaysha oo joogto ah ayaa la qaataa, iyada oo aan la kala saarin qayb ama saxan, hubinta sii socoshada korantada oo aad u wanaagsan, khasaaraha oo yaraada, iyo la yareeyo khatarta kulaylka deegaanka. Qaabaynta dabaysha ee la hagaajiyay waxa ay awood u siinaysaa nakhshad sare oo ka hortag ah oo ah 34%, si aad ah uga saraysa transformers-ka caadiga ah ee qiimaynta la midka ah (sida caadiga ah 12–16%), si wax ku ool ah u xaddidaysa qulqulka wareega gaaban iyo kor u qaadida xasiloonida nidaamka. The100MVA koronto weynwaxaa lagu habeeyey koox-waxyeelo YNd1 ah.

100mva-transformer-winding-optimized-layout-high-impedance-34-percent-ynd1
high-conductivity-copper-100mva-transformer-winding-material

 

 

03 Naqshadeynta Nidaamka Haamaha

3.1. Naqshadaynta iyo Dhismaha Haamaha

Haanta waxay qabataa daboolka{0}qaab dhismeedka nooca, fududaynta rakibaadda iyo dayactirka korontada waaweyn. Marka la barbar dhigo gambaleelka - nooca taangiyada, way fududahay in la sameeyo, la raro, iyo adeega goobta. Waxaa laga dhisay taarikada birta ah ee alxanka ah oo laga buuxiyey 25# PCB-saliid macdanta bilaashka ah, haanta waa adag tahay, la isku halayn karo, waxayna shaqadeeda qabataa maalinba maalinta ka dambaysa.

100mva-132kv-22kv-data-center-power-transformer bell-type tanks

 

3.2 alxanka iyo gaashaanka magnetic

100mva-132kv-22kv-data-center-power-transformer-oil-tank-magnetic flux shields

Dhammaan saliidda -qaybaha ay ku jiraan{1} alxanka kala go'a, alxanka taarka, iyo alxanka tolida lama ogola, hubinta{3}} adkaynta saliida muddada dheer. Gaashaannada qulqulka magnetic, ee lagu rakibay gidaarada taangiga gudaha iyo labada daraf ee harqoodyada xudunta u ah, waxay xakameeyaan qulqulka qulqulka, ka hortagga kulaylka gudaha, waxayna yareeyaan khasaaraha dheeraadka ah.

3.3 Daboolka Haamaha iyo Helitaanka

Haanta waxay daboosha dhaadhacyada si ay biyaha roobka ugu daadiso si dabiici ah; Qodobbada hagaajinta ayaa loo bixiyaa lifaaqyada, taasoo ka dhigaysa shaqada ugu sareysa mid ammaan u ah shaqaalaha. Dhammaan xayndaabyada bannaanka iyo qaybaha birta ah waa kuwo aan cimiladu karin, daxalka{1} adkaysi u leh, oo la kulma ugu yaraan ilaalinta IP55 sida ku cad IEC/AS 60529. Xaqiijinta waarta cimilada kulaalayaasha koonfurta Malaysia halkaas oo koronto-baddeyaasha waaweyn la geeyo.

100mva-132kv-22kv-data-center-power-transformer-oil-tank-IP55 protection

 

3.4 Kahortagga - Ilaalinta Daxalka

100mva-132kv-22kv-data-center-power-transformer-oil-tank-anti-corrosion protection

Nidaamka daxalka oo dhamaystiran ayaa lagu dabaqay dhammaan qaybaha birta ee daboolan: taangiga ugu weyn iyo kaydiyeyaasha waa la toogtay{1}}oo lagu ilaaliyay daahan badan{2}}lakab warshadeed; hiitarka, qaybaha qaab dhismeedka, jaranjarooyinka, iyo qalabyada dibadda ayaa ah kuwo kulul{3}} kontaroolada waxaa lagu dhammeeyaa buufinta zinc ama daahan budada ah, gaar ahaan transformers koronto oo ka shaqeeya agagaarka kulaylaha, xeebaha, iyo si aad ah u wasakhaysan, hubinta dayactirka-nolosha adeega bilaashka ah ee ugu yaraan 20 sano ah.

 

 

04 Qalabyada Transformer Critical

4.1 Vacuum OLTC

Transformer-ka weyn waxa uu leeyahay shagaag Huaming vacuum OLTC (SHZVIII{10}}1000Y/72.5C-14273W) ee HV dabaysha, oo leh dahaar lagu habeeyey dhexdhexaad (350/140). Waxay bixisaa +10.5% ilaa -25.5% nidaamin 1.5% tillaabooyinka 25 jago, loogu talagalay in lagu yareeyo xoogaga wareega gaaban, hubinta kala duwanaanshaha cakiran, iyo taageer hawlgalka barbar socda.

vacuum-oltc-shanghai-huaming and active part of 100 MVA large power transformer including core and winding assembly

 

4.2 Fiber Optic Heerkulka Dabaylaha

Cabbirka heerkulka dabaylaha tooska ah waxa bixiya 8{1}}nidaamka fiber optic kanaalka, kaas oo si toos ah ula socda heerkulka goobta kulul wakhtiga dhabta ah. Marka la barbardhigo hababka caadiga ah ee ku salaysan heerkulka saliidda iyo qiyaasta hadda jirta, nidaamkani wuxuu bixiyaa saxsanaan sare, jawaab-celin kuleyl ah oo degdeg ah iyo difaac faragelinta korantada, awood u siinaya ilaalin toos ah oo la isku halleyn karo iyo hagaajinta amniga hawlgalka.

 

4.3 RIP engegan{1}Nooca Bushings

100mva-132kv-22kv-data-center-power-transformer-Bushings
100mva-132kv-22kv-data-center-power-transformer RIP Dry-Type Bushings

 

RIP engegan{0}nooc baadiyaha leh saliid{1}naqshad bilaasha ah iyo guriyeynta polymer ayaa laga codsadaa HV, LV iyo terminal dhexdhexaad ah si waafaqsan IEC/AS 60137. Isticmaalka tignoolajiyada Micafil ama HSP ee la xaqiijiyay, baadiyaha waxay bixiyaan awood farsamo sare leh, wax qabad heer sare ah oo koronto ah iyo karti qaadis hada{3}} Masaafo dheer oo gurguurta iyo iska caabbinta qoyaanka sare, waxay si gaar ah ugu habboon yihiin koronto-baddelayaasha waaweyn ee ka shaqeeya - qoyaan sare iyo deegaan wasakhaysan.

 

 

05 Hufnaanta, Kalsoonida & Waxqabadka Nolosha Nolosha

5.1 Waxtarka Tamarta & Waxqabadka Luminta

Transformer-ku wuxuu la kulmaa IEC PEI Heerka 2 oo leh hufnaan 99.68%.

Khasaarooyin hoose, oo lagu gaadho qaabaynta xudunta u ah la wanaajiyey iyo dabaylaha, waxay bixiyaan faa'iidooyinka kharashka meertada nolosha {{0}gaar ahaan muhiim u ah sida joogtada ah ugu shaqaynta transformers koronta weyn ee xarumaha xogta.

 

5.2 Kalsoonida & Amniga Hawlgalka

Naqshadeynta xannibaadda 34% waxay hagaajinaysaa dulqaadka qaladka iyo xasilloonida nidaamka.

Marka lagu daro OLTC iyo la socodka heerkulka, waxay hubisaa hawlgal la isku halayn karo, kaas oo ah shuruudda muhiimka ah ee hawlgalka -Transformers koronto oo muhiim ah.

 

5.3 Ku Haboonaanshaha Saldhigyada Xarunta Xogta

Naqshad gaar ah oo loogu talagalay codsiyada xarunta xogta, koronto-sameeyahan weyn wuxuu bixiyaa buuq yar, waxtar sare, iyo waxqabad xasilloon.

Naqshadeedu waxay taageertaa helitaanka sare iyo miisaanka, buuxinta shuruudaha adag ee kaabayaasha dhijitaalka ah ee casriga ah.

 

06 Baakadaha iyo gaadiidka

6.1 Xirxirida

100mva-large-power-transformer-main-tank-nitrogen-protection-packing
100mva-transformer-transport-securing-chain-fixing-and-protection
100mva-large-power-transformer-key-components-protection-bubble-wrap-detail
100mva-large-power-transformer-accessories-wooden-case-packing

 

 

6.2 dhoofinta

Cutubkan 100 MVA ah (~ 155 tan), qorshe gaadiid oo gaar ah ayaa la hirgeliyay.

Transformer-ka waxa lagu soo raray saliid{0} bilaash waxaana ka buuxsamay hawo engegan iyadoo cadaadis togan saaran yahay, iyada oo qoyaanka si adag loo xakameeyay. Korjoogteynta naxdinta leh, baakadaha la xoojiyay, iyo saadka la kontoroolo ayaa xaqiijiyay gaarsiinta badbaado leh{2}}ku dhaqanka caadiga ah ee qaadista koronto-sameeyayaasha cabbirkan.

 

100mva-power-transformer-on-ship-ready-for-transport
100mva-large-power-transformer-at-loading-port
100mva-transformer-accessories-lifting-to-ship
100mva-large-power-transformer-lifting-to-vessel

 

Macaamiisha qiimeeya Transformers koronto waaweyn qiimaha iyo qiimaha, arrimaha sida naqshadeynta, agabka, iyo agabka ayaa door muhiim ah ka ciyaara. Soo-saare khibrad leh, Scotech waxay bixisaa xalal la hagaajiyay oo dheellitiraya waxqabadka iyo qiimaha.

 

 

Hot Tags: Transformers koronto oo waaweyn, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha