2500 KVA Substation Transformers-34.5/0.48 KV|Nicaragua 2026
Awoodda: 2500 kVA
Voltage: 34.5/0.48 kV
Muuqaalka: 99.37% hufnaan
Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha ugu kalsoonida badan ee 2500 kva transformers -34.5/0.48 kv|nicaragua 2026 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. nala soo xidhiidh wixii faahfaahin ah

Loo dhisay 24/7 waajibaad, looguna talagalay eber yaabab - Beddelka Qaybaha Unuggu wuxuu ilaaliyaa hawlahaaga muhiimka ah.
01 Guud
1.1 Sharaxaada Mashruuca
750 kVA unug koronto-bixiye ayaa la geeyey Nicaragua sanadka 2026. Awoodda la qiimeeyay ee transformerku waa 2500 kVA oo leh qaboojin KNAN. Korantada sare waa 34.5 kV oo leh ± 2 * 2.5% garaacista (NLTC), korantada hoose waa 0.48 kV, waxay sameeyeen koox vector ah Dyn11.
Transformer-ka awooda sare leh waa qayb ka mid ah isla mashruuca warshadaynta dahabka ee La India ee Nicaragua, isaga oo u adeegaya dalabaadka culayska culus ee xarunta - oo ay ku jiraan qalabka habaynta, gaadiidka qaada, iyo nidaamyada kaalmeeya ee u baahan cufnaanta awood weyn. Sida dhiggeeda 750kVA, cutubkani waa inuu u adkaystaa cimilada kulaylaha ee goobta: heerkulka ilaa 32.8 digrii, qoyaan qaraabo ah oo gaadhay 79%, roobka sanadlaha ah ee 1,239mm, iyo deegaan ay ku raran yihiin boodh bakteeriyada wasakhaysan oo biyaha ku salaysan nadiifinta qalabka korontada la xaddiday.
SCOTECH's 2500kVA substation transformer ayaa loo habeeyay codsigan saxda ah. Waxay ka kooban tahay suuf dibadda ah oo adag oo lagu rakibay xayndaab, qaboojin KNAN, iyo FR3 dareere ester-dabiici ah - PCB bilaash ah, dab aad u adkeysi leh, iyo dhexdhexaad biodegradable ah oo ka sarreeya saliidda macdanta ee maaraynta qoyaanka iyo ilaalinta xaashida, lagama maarmaanka u ah isku halaynta muddada dheer ee xaaladaha qoyan. Transformer-ku wuxuu u hoggaansamaa shuruudaha naqshadaynta seismic ee RNC 07 iyo ASCE{6}}/IBC2024, waxaana loo dhisay 24/7 adeeg joogto ah oo leh nolol naqshadayn 25 sano ah. Qalab dhamaystiran oo ay ku jiraan heerkulbeegyada saliidda iyo dabaylaha, tilmaamayaasha heerka dareeraha, aaladaha cadaadiska cadaadiska, gaaska gudbinta, iyo neefta -waxay xaqiijiyaan muuqaal shaqayn buuxda iyo ilaalin inta u dhaxaysa muddada dayactirka la qorsheeyay. Beddelka tuubada NLTC ee leh ± 2 × 2.5% kala duwanaanta dhinaca aasaasiga ah waxay dejisaa kala duwanaanshaha korantada ee caadiga ah ee gobollada macdanta fogfog.
Qaybtan 2500kVA waxay dhamaystiraysaa dhigeeda yar si ay u daboosho baaxadda buuxda ee baahida qaybinta tamarta warshadda. Si wada jir ah, waxay xoojiyaan ka go'anaanshaha SCOTECH ee ah in ay soo bandhigto howlgalka xalalka awoodda muhiimka ah ee waaxda macdanta ee deegaannada adag.
1.2 Tilmaamaha Farsamada
1500 kVA cutubka qayb ka mid ah tafatirka tafatirka nooca iyo xaashida xogta
|
loo geeyey
Nicaragua
|
|
Sannadka
2026
|
|
Nooca
koronto-bixiye-hoosaadka cutubka
|
|
Heerka
IEEE C57.12.36-2007
|
|
Awood lagu qiimeeyay
2500 kVA
|
|
Soo noqnoqda
60HZ
|
|
Marxaladda
3
|
|
Nooca qaboojinta
KNAN
|
|
Korantada aasaasiga ah
34.5 kV
|
|
Voltage Secondary
0.48 kV
|
|
Qalabka dabaysha
Copper
|
|
Kooxda Vector
Dyn11
|
|
Caqabada
5.75%
|
|
Waxtarka
99.37%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Wax Xamuul ah ma jiro
2.5 kW
|
|
Load Lumista
24 kW
|
1.3 Sawirro
750 kVA halbeegga is beddelka jaantuska sawirka iyo cabbirka
![]() |
![]() |
![]() |
![]() |
02 Wax-soo-saarka
2.1 Haanta

Haanta ugu weyn waxaa laga dhisay saxan bir kaarboon ah oo culeyskiisu culus yahay, oo leh awood farsamo oo adag oo loogu talagalay naqshadeynta ilaalinta la xoojiyey ee ka dhanka ah cadaadiska wareegga gaaban ee gudaha. Dhammaan tolmada alxanka waxaa lagu sameeyaa kormeer cidhiidhi ah oo buuxa. Ka dib markii la toogto iyo ka-hortag fosfat, lakabyo badan oo ka hortagga daxalka warshadaha ayaa la mariyaa, taasoo keenaysa iska caabin UV sare iyo waxqabadka ka-hortagga daxalka ee kulaylaha, huurka sare ee deegaanka macdanta dibadda. Lugaha kor u qaadaya iyo suufka jackingka ayaa horay loo welded si loo qaado ku haboon iyo rakibida goobta. Taangiyada dhoobada badan ee taangiyada ayaa la siiyay si loo dejiyo ilaalin la isku halayn karo. Xerada guud waxay la kulmeysaa heerka ilaalinta IP54, kahortaga boodhka, roobka da'aya iyo shayga ajnabiga ah ee soo galaya gudaha hawlgalka mudada dheer.
2.2 HV / LV sanduuqa Cable
Sanduuqyada fiilooyinka korantada sare ee kala duwan iyo korantada yar ayaa lagu rakibay daboolka taangiga beddelka, oo loo naqshadeeyay marinka fiilada gelitaanka hoose sida mashruuca lagu qeexay. Xayndaabka qashin-qubka ah ee adag waxa uu gaadhaa caddaynta boodhka iyo waxqabadka cimiladu. Nadiifinta gudaha ee ku filan waxay dejisaa fiilooyinka korantada ee macaamiisha, lugaha fiilooyinka, baararka dhulka lagu dhejiyo iyo joojinta xiritaanka qalliinka. Helitaanka la xiri karo waxay dabooshaa fududeynta joojinta fiilada, kormeerka muuqaalka iyo dayactirka joogtada ah. Sanduuqa fiilada HV waxa lagu qiyaasaa fiilooyinka korantada ee dhexdhexaadka ah, halka sanduuqa LV loo habeeyey fiilooyinka korantada korantada badan ee korantada yar, iyadoo la raacayo dhaqanka joojinta garoonka ANSI.



2.3 Neefsashada
Neefsashada silica jel fuuqbaxa ayaa lagu rakibay dusha sare ee kaydiyaha saliidda, isaga oo u dhaqmaya sidii isdhexgalka jawiga nidaamka ilaalinta saliidda. Waxaa lagu rakibay dabin saliideed si loo sifeeyo siigada hawada; midabka silica jel muuqaal ahaan digniin u diraysa shaqaalaha dayactirka marka nuugista qoyaanku gaadho dhereg. Waxay ka celisaa hawada hawada qoyan inay soo gasho kaydiyaha inta lagu jiro mugga saliidda wareegyada balaadhinta kulaylka, ilaalinta ka ilaalinta saliidda wasakhaynta qoyaanka iyo kordhinta nolosha adeegga alaabta dahaarka gudaha, taas oo muhiim u ah huurka sare ee xaaladaha goobta kulaylaha.
2.4 Gudbinta Gaaska (Buchholz Relay)
Gaadhida gaaska Buchholz waxa lagu rakibay dhuunta isku xidha taangiga weyn iyo kaydiyaha saliida, isaga oo u adeegaya sidii asaaska ilaalinta khaladka korantada. Waxay ogaataa gaas urursan oo ay sababeen cillado yaryar oo gudaha ah iyo saliid fiiqan oo kor u kacday oo ay keentay dabaylo daran. Ku dhisan alaarmiga & xiriirrada safarku waxay soo gudbiyaan digniinta fog nidaamka PCS/SCADA: signalka alaarmiga wuxuu u kiciyaa gaas gaabinaya, halka amarka safarka lagu hawlgelinayo kor u kaca saliidda ee ay sababto cilladaha waaweyn ee gudaha. Waxay bixisaa digniin marxaladda hore ee ka soo horjeeda xaalufka dahaarka, kulaylka meel kulul iyo cilada qiiqa gudaha.

2.5 Badbaadiyaha Saliidda

Badbaadiyaha saliidda ee birta la sameeyay (taangi ballaadhinta) ayaa lagu rakibaa korka beddelka, magdhowga kala duwanaanshaha mugga saliidda ee uu sababay isbeddelka heerkulka. Waxay ilaalisaa cadaadiska togan ee gudaha taangiga weyn, waxay yaraynaysaa xidhiidhka tooska ah ee u dhexeeya saliidda dahaarka iyo jawiga, waxayna hoos u dhigtaa gabowga oksaydhka saliidda. Tilmaanta heerka saliideed ee isku dhafan oo leh xiriiriyeyaasha alaarmiga ayaa kormeeraya mugga saliidda waqtiga dhabta ah; Calaamadaha digniinta heerka saliida sare/hoose waxaa lagu xidhi karaa terminaalka la socodka fog. Dekadda buuxinta, balaastigga biyo-mareenka iyo sanbabada muunadda ayaa hore loogu diyaariyey buuxinta saliidda, muunad-samaynta iyo daadinta shaqada goobta.
2.6 Sanduuqa Terminalka
Sanduuqa terminaalka kaalmuhu waa xayndaab bir ah oo la xidhi karo oo xidhidhsan silig wareeg labaad. Xirmooyinka terminaalka ee hore loo calaamadeeyay waxay dejiyaan dhammaan wareegyada calaamada qalabka ilaalinta, oo ay ku jiraan gudbinta Buchholz, waalka gargaarka cadaadiska, tilmaame heerkulka saliidda iyo tilmaame heerkulka dabaylaha. Waxay ka soocaa wareegga muhiimka ah ee awoodda sare iyo kormeerka korantada hooseeya & fiilooyinka digniinta, waxay siisaa qanjirrada fiilooyinka la isku halayn karo ee gelitaanka fiilada kontoroolka, waxayna ilaalisaa xidhiidhada labaad ee ka ilaalinta boodhka dibadda iyo qoyaanka, fududaynta isku xirka dhirta PLC iyo nidaamyada SCADA.

2.7 Sanduuqa Transformer Outlet ee hadda jira

Sanduuqa CT outlet ee u go'ay ayaa ku yaal terminal sare oo lagu dhisay transformers hadda. Waxay ka soocdaa fiilooyinka CT-ga sare ee qaybaha ugu muhiimsan ee tamarta sare. Xirmooyinka wareegga gaaban ee calaamadeysan ayaa la bixiyaa si badbaado leh oo CT ah oo loogu talagalay hawlgalka wareegga gaaban ee gaaban inta lagu jiro hawlgelinta iyo dayactirka. Taarikada qanjidhada waxaa loogu talagalay gelitaanka fiilada qalabka gaashaanka ah. Qaybtan gaarka ah waxay ka fogaanaysaa khatarta fiilooyinka, waxay dammaanad qaadaysaa badbaadada shaqaalaha waxayna hubisaa gudbinta calaamadaha deggan ee cabbiraadda iyo gudbinta ilaalinta.
2.8 Weji eber Bushing (Bush-dhexdhexaad ah)
Meesha dhexdhexaadka ah ee wejiga eber waxaa loogu talagalay wareegga dhexdhexaadka ah ee hooseeya ee si adag. Waxa ay siisaa dahaar adag iyo taageero makaanik ah oo ah sunta rasaasta dhexdhexaadka ah, oo leh masaafo ku filan oo gurguurta oo ku habboon jawiga macdanta wasakhaysan ee dibadda. Waxay si buuxda ula jaan qaada 4 nidaamka qaybinta tamarta hoose ee fiilada, waxayna awood u siinaysaa joojinta fiilada dhexdhexaadka ah ee la isku halayn karo. Baakadaha xidhidhiyaha tayada sare leh ayaa ka hortagaya galinta biyaha roobka iyo qoyaanka ee isku xidhka galitaanka haanta.

2.9 Radiator

Hidiyeeriyeyaasha nooca saxanka ah waxay qaataan qaab-dhismeed kuleyl aad u sarreeya oo loogu talagalay KNAN (Kernel Natural Air Natural) qaabka qaboojinta. Qaybaha shucaaca waxa ay ku xidhan yihiin haanta weyn iyada oo la go'doominayo fallaadhaha balanbaalista; Bangiyada raadiyaha gaarka ah waa la go'doomin karaa beddelka iyada oo aan la daadin saliidda beddelka taangiga oo buuxa. Nashqada marinka qulqulka saliida ee la hagaajiyay waxa uu wanaajiyaa isweydaarsiga kulaylka dabiiciga ah, si wax ku ool ah ayuu u baabi'iyaa kulaylka ay dhaliso xudunta iyo khasaaraha dabaylaha ee hoos yimaada hawlgalka culayska buuxa ee joogtada ah, oo waxa uu ku hayaa dabaylaha & heerkulka sare u kaca heerkulka IEEE ee la cayimay ee 24 7 365 wareegtada xilka joogtada ah ee heerkulka deegaanka kulaalale.
03 Tijaabinta
Cutub kastaa wuxuu dhammaystiraa tijaabada aqbalaadda warshadda baaxadda buuxda (FAT) iyada oo u hoggaansan ANSI/IEEE C57.12.00 2021 & C57.12.90 2021 ka hor intaan la dhoofin. Baaxadda tijaabada waxaa ka mid ah cabbiraadda caabbinta dabaysha, saamiga isbeddelka & hubinta xiriirka wejiga, wax qabad la'aan & tijaabo culeys ah oo hadda jira, luminta culeyska & cabbirka xannibaadda wareegga gaaban, tijaabinta adkaysiga korantada ee la dabaqay, tijaabinta adkaysiga korantada, 24 saac tijaabada adkeynta cadaadiska cadaadiska, cabbirka caabbinta dahaarka, iyo tijaabada xoogga dielectric ee saliidda. Xaqiijinta shaqaynaysa ee dhammaan xidhiidhada digniinta/safarka ee agabka ilaalinta ayaa la sameeyaa. Warbixinta imtixaanka saxiixan oo dhameystiran ayaa lala imaanayaa transformer kasta. Tijaabada heerkulka kor u kaca waa ikhtiyaari marka macmiilku codsado.


04 Baakaynta iyo dhoofinta
4.1 Baakad


4.2 dhoofinta


05 Goobta iyo Kooban
Qeybtan 750 kVA substation oil immersed transformer waxaa lagu farsameeyay halbeegyada ANSI/IEEE ee codsiyada warshadaha bannaanka iyo macdanta culus ee hoos yimaada nidaamka 60 Hz. Isku dhafka haanta birta adag, suuit ilaalinta korantada oo dhameystiran, nidaamka qaboojinta isku halaynta sare iyo qaybo kaabayaal ah oo si wanaagsan loo habeeyey, waxay taageertaa saacadaha 24 ee hawlgalka culeyska buuxa ee heerkulka sare, huurka kuleylka kuleylka badan. Dhammaan qalabyada si buuxda ayaa loogu rakibay si sahlan loo rakibo, hawlgelinta iyo la socodka fogaanta. Nidaamyada tijaabada warshadaha adag waxay dammaanad qaadayaan waxqabadka xasilloon, lumis hoose iyo nolosha adeegga muddada dheer ee xallinta qaybinta tamarta substation-ka.

Hot Tags: 2500 kva substation transformers-34.5/0.48 kv|nicaragua 2026, Shiinaha 2500 kva substation transformers-34.5/0.48 kv|nicaragua 2026 saarayaasha, alaab-qeybiyeyaal, warshad
You Might Also Like
2000 kVA Qaybinta Subsformer-44/0.48 kV|Kanada 2025
3000 kVA Substation koronto-44 / 0.6 kV|Kanada 2025
3750/4250 kVA Substation Transformer-13.8/0.48 kV|US...
1000/1150 kVA Qaybinta Beddelka Substation-13.8/0.48...
1500 KVA Saldhigyada Korontada-5/0.48 KV|USA 2025
4 MVA Transformer Substation-34.5/0.48 KV|Nicaragua ...
U dir sooji