1500 KVA 12.47*4.16/0.48 KV Sadex Waji Oo Saxiix Ku Rakiban BESS Go'doominta BESS|USA 2026

1500 KVA 12.47*4.16/0.48 KV Sadex Waji Oo Saxiix Ku Rakiban BESS Go'doominta BESS|USA 2026

Dalka la geynayo: Ameerika 2026
Awoodda: 1500kVA
Voltage: 12.47 / 0.48 kV
Muuqaalka: BESS Go'doominta Transformer
U dir sooji

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha 1500 kva 12.47 * 4.16 / 0.48 kv saddex waji oo lagu dhejiyay beddelka go'doominta bess|USA 2026 ee Shiinaha. Fadlan xor u noqo inaad iibsato kharash{7}alaabo hufan oo iib ah halkan oo ka hel jaantusyada warshadeena. nala soo xidhiidh wixii faahfaahin ah

 

image001

1500 kVA Saddex Waji oo suuf ah oo lagu rakibay BESS Go'doon beddelka Kaydinta Tamarta ee La isku halleyn karo

 

 

01 Guud

1.1 Sharaxaada Mashruuca

Qalabkan 500kVA ee saddexda waji ah ee ku rakiban transformer-ka waxa la geeyey macmiil Maraykan jooga oo loogu talagalay Nidaamka Kaydinta Tamarta Battery (BESS). Waxa la dhameeyay Sebtembar 2026.

Beddelka go'doominta 1500 kVA BESS wuxuu u beddelaa 480 V dhanka PCS. Dhankeeda sare -Dhinaca danabku waxa uu bixiyaa 4.16 kV iyo 12.47 kV ee isku xidhka kala duwan ee shuruudaha xidhiidhka

Koronto-dhaliye ahaan, waxay kala saartaa wareegyada hoose ee -voltage iyo dhexdhexaadka{1} iyadoo la kala wareejinayo awooda dhexdooda.

Qaabayntani waxay taageertaa isbarbardhigga korantada, go'doominta korantada, iyo wareejinta korantada ee la isku halayn karo gudaha rakibaadda BESS.

suufka ku rakiban BESS transformer wuxuu isticmaalaa dareeraha dahaaran ee FR3, qaboojinta KNAN, iyo dabaylaha aluminium ee hawlgalka bannaanka. Wareegeeda - quudinta dhintay -Naqshadaynta hore waxay taageertaa suufka - rakibaadda rakiban iyo codsiyada dhexdhexaadka -voltage BESS.

Isku xidhka 12.47 kV iyo 4.16 kV labaduba waxay ka kooban yihiin beddelayaasha tuubada iyo xidhidiyeyaasha qalliinka ah. Gaashaanka dhulka dhigay ayaa lagu dhex daray si kor loogu qaado go'doominta korantada ee u dhaxaysa - iyo kuwa hooseeya - wareegyada korantada.

 

 

 

1.2 Tilmaamaha Farsamada

1500kVA saddex weji suuf ah oo ku rakiban tafatirka tafatirka iyo xaashida xogta

loo geeyey
Ameerika
Sannadka
2026
Nooca
Saddex weji suuf Buur Transformer
Heerka
IEEE Std C57.12.34-2022
Awood lagu qiimeeyay
1500KVA
Soo noqnoqoshada
60HZ
Quudinta
Loop
Hore
dhintay
Marxaladda
saddex
Nooca qaboojinta
KNAN
Insulant dareere ah
FR3 Saliid
Korantada aasaasiga ah
12470x4160 V
Voltage Secondary
480 V
Kooxda Vector
Dyn1
Qalabka dabaysha
Aluminium
Xakamaynta (HV)
5.75%
Waxtarka
DOE
Taabo Beddelka (LV &HV)
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
1545 W
Load Lumista
10540 W
Agabka
Habaynta caadiga ah

 

1.3 Sawirro

2000kVA saddex waji oo suuf ah oo ku rakiban sawir beddele iyo saxan magaceed

image003 image005

 

 

02 Wax-soo-saarka

2.1 Core, Winding & Haanta

image007
image009
image011

 

2.2 Dhulka & Gaashaanka

image013

Baararka dhulka waxaa lagu bixiyaa labada sare{0}}iyo kuwa hoose{1}} dhinacyada korantada ee isku xirka dhulka loo baahan yahay. Gaashaan-dhis leh ayaa lagu dhex daray naqshadda beddelka ee go'doominta korantada ee u dhaxaysa wareegyada aasaasiga ah iyo kuwa sare.

 

2.3 Bushing

image015
image017

Dhinaca sare - dhinaca korantada waxay isticmaashaa duurka dahaaran ee la kala sooci karo ee meydadka{1}dhexe ee hore{2}}isku xidhka korantada. Qaabayntani waxa ay taageertaa isku xidhka fiilada nabdoon ee gudaha suufka -Qaybta beddelka ee rakiban.
Dhinaca hoose ee - dhinaca korantada waxa ay isticmaashaa sideed{1}}dalool -nooca bushings ee sare{3}} xidhiidhada 480 V hadda. Habaynta baadiyaha ayaa bixisa isku xirka terminal sugan oo u dhexeeya transformer-ka iyo qalabka beddelka tamarta BESS.

 

2.4 Beddelka & Ilaalinta Qalliinka

image019
image021

Transformer-ku waxa uu bixiyaa 12.47 kV iyo 4.16 kV sare -qaabaynta korantada oo leh awood u dhiganta hagaajinta korantada.
Labada qaabayn ee sare - waxay ku qalabaysan yihiin xidhiyaal sare oo u go'an ilaalinta tamarta xad dhaafka ah.
Bedelaha tuubada wareega ee off{0}wuxuu bixiyaa ±2 × 2.5% taabasho dhinacyada danab ee la cayimay. Afarta-raraka booska-jarida jebinta waxay ku siinaysaa awooda beddelka isku xidhka transformer-ka.

 

2.5 Kormeerka & Ilaalinta

Transformer-ku waxa uu ku qalabaysan yahay heerkulbeeg, cabbirka cadaadiska faakuumka, tilmaame heerka dareeraha, iyo aaladda cadaadiska cadaadiska. Aaladahani waxay bixiyaan macluumaadka deegaanka ee ku saabsan heerkulka, cadaadiska gudaha, heerka saliidda, iyo xaaladaha cadaadiska aan caadiga ahayn.
Nidaamka la socodka wuxuu taageeraa kormeerka joogtada ah ee transformerka inta lagu jiro hawlgalka BESS. Qalabka cadaadiska cadaadiska wuxuu ka ilaaliyaa cadaadiska gudaha ee xad-dhaafka ah ee xaaladaha shaqada ee aan caadiga ahayn.

image023

 

 

03 Tijaabinta

Heerka Imtixaanka

image025

Natiijooyinka Imtixaanka

image027

image029

 

 

04 Baakaynta iyo dhoofinta

4.1 Baakad

image031
image033

 

4.2 dhoofinta

image035

 

Hot Tags: 1500 kva 12.47*4.16/0.48 kv saddex weji suuf ah oo ku rakiban koronto-bixiye bess go'doon ah|usa 2026, Shiinaha 1500 kva 12.47*4.16/0.48 kv saddex weji suuf oo ku rakiban koronto-bixiye bess go'doon ah|USA 2026 saarayaasha, alaab-qeybiyeyaasha, warshad