2500 kVA Beddelka Qalalan-10/0.4 kV|Georgia 2025

2500 kVA Beddelka Qalalan-10/0.4 kV|Georgia 2025

Dalka: Georgia 2024
Awoodda: 2500kVA
Voltage: 10/0.4kV
Feature: oo leh heerkulka xakamaynta
U dir sooji

 

 

2500 kva dry transformer

Nooca Qalalan ee Resinka ah - Doorashada Waxtarka, Badbaadada, iyo Eco - Gudbinta Awood Saaxiibtinimo!

 

01 Guud

1.1 Asalkii Mashruuca

Qalabka qalalan ee 2500 kVA resin kabka ah waxaa la geeyey Georgia sanadka 2024, awooda lagu qiimeeyay isbedbedelku waa 2500 kVA. Korontada sare ee qalabkan qalalan ee nooca qalalan waa 10kV, tamar yarna waa 0.4kV. Qalabkan nooca qallalan ee korantada sare leh wuxuu ku qalabeysan yahay beddelka tabaha culeyska, cabbirka taabashadu waa ± 2 * 2.5% dhinaca hoose, qaboojinta waa KNAN/KNAF.

Transformers nooca qallalan ee looxa shubay waxay ka dhigan yihiin meesha ugu saraysa ee tignoolajiyada casriga casriga ah, oo si khibrad leh isugu qasay hufnaanta korantada iyo adkaysiga farsamaysan ee adag. Dhismaha cusubi waxa uu ku lug leeyahay in dabaylaha lagu xidho qolof adag oo epoxy ah, kaas oo aan kaliya wanajin cimriga beddelka laakiin sidoo kale waxa uu bixiyaa iska caabin gaar ah oo ka dhan ah arrimaha deegaanka sida qoyaanka, boodhka, iyo isbedbeddelka heerkulka. Tilmaamahan gaarka ah wuxuu hubinayaa in beddelayaasha nooca qallalan ee resin-ka ah ay ilaaliyaan waxqabadka ugu wanaagsan ee xaalado kala duwan oo adag, taasoo ka dhigaysa mid ku habboon isticmaalka codsiyada warshadaha kala duwan.

Intaa waxaa dheer, transformers-yadani waxay mudnaanta siinayaan badbaadada iyagoo meesha ka saaraya khatarta saliidda daadinta iyo yaraynta khatarta dabka, faa'iidada muhiimka ah ee goobaha dadku ku badan yihiin iyo xarumaha warshadaha. Rakibadooda waxay u baahan tahay dayactir yar marka loo eego saliidda dhaqameedka{1}}Transformers-ka buuxa, taasoo horseedaysa kharashyada hawlgelinta oo hoos u dhaca wakhtiga.

Marka laga soo tago awoodooda farsamo, resin cast transformers nooca qalalan ayaa daboolaya baahida sii kordheysa ee xalalka waara ee qaybta tamarta. Naqshadoodu waxay la socotaa heerarka deegaanka, taasoo gacan ka geysaneysa hoos u dhigista raadka kaarboonka iyo taageeridda yoolalka waaridda ee warshado kala duwan. Haddi ay tahay mashaariicda tamarta la cusboonaysiin karo, dhismayaasha ganacsiga, ama hawlaha warshadaha, resin cast transformers type engegan ayaa ah doorashada caqliga leh ee ururada doonaya inay kor u qaadaan kaabayaasha korantada iyagoo kor u qaadaya masuuliyada deegaanka.

 

 

1.2 Tilmaamaha Farsamada

2500 kVA resin tuurista nooca qalalan qeexitaanka iyo xaashida xogta

loo geeyey
Georgia
Sannadka
2024
Nooca
Transformer nooc qalalan oo shub ah
Qalabka muhiimka ah
xaashi bir silikoon ku jihaysan hadhuudhka
Heerka
IEC60076-11, EN50541-1, ISO9001, ISO14001
Awood lagu qiimeeyay
2500kVA
Soo noqnoqoshada
50 HZ
Kooxda Vector
Dyn11
Marxaladda
Saddex
Nooca qaboojinta
KNAN/KNAF
Korantada aasaasiga ah
10 kV
Voltage Secondary
0.4 kV
Qalabka dabaysha
Aluminium
Caqabada
6%
Taabo Beddelka
NLTC
Riixista Range
± 2 * 2.5% @ danab hoose
Wax Xamuul ah ma jiro
3.2KW
Load Lumista
19KW
Heerka dahaarka
F

 

1.3 Sawirro

2500 kVA resin tuurista qalalan nooca beddelka jaantus sawir iyo cabbir.

2500 kva dry transformer drawing 2500 kva cast resin type transformer nameplate

 

 

02 Wax-soo-saarka

2.1 Core

Xudunta resinka{0}kabka qalalan{1} nooca transformerka ayaa muhiim u ah hufnaantiisa, isticmaalka tamarta, iyo xasiloonida hawlgalka. Waxa laga sameeyay -qabow badan - xaashida birta silikoon giringireen, xudunta udub dhexaad u ah goyn 45 digrii ah iyo tallaabo{6}}dhismaha dhabta ah ee wanaajiya qulqulka birta oo yareeya khasaaraha iyo qaylada. Habka shubista xabagta - waxa ay wanaajisaa xoogeeda makaanikada iyo iska caabinta gariirka, iyada oo hubinaysa waxqabadka adag.

Xuddunta waxa lagu dahaadhay daxal - resin epoxy adkeysi u leh si uu uga ilaaliyo qoyaanka iyo oksaydhaynta, halka kanaalada fidinta kulaylka hufani ay ka hortagayaan kulaylka, ilaalinta{1} waxqabadka muddada dheer. Ka faa'iidaysiga otomaatiga horumarsan xagga wax soo saarka waxay hubisaa tayada iyo saxnaanta joogtada ah. Iyada oo lumista tamarteeda hoose, qaylada ugu yar, iska caabbinta daxalka, iyo nolosha adeegga la dheereeyey, naqshadayntan udub-dhexaadka ah waxay u taagan tahay goynta{4}} injineernimada cirifka ee nidaamyada tamarta casriga ah.

cast resin transformer silicon electrical steel sheet

 

2.2 Dabaylaha

2500kva cast resin type transformer winding

Dabaylaha korantada yar ayaa laga sameeyay xaashi naxaas ah ama aluminium, oo lagu daboolay lakabyo badan. Naqshaddooda helical waxay bixisaa xasilooni aad u fiican inta lagu jiro wareegyada gaaban waxayna yareysaa khasaaraha "saameynta maqaarka."

Dabaysha tamarta sare waxay ka kooban tahay fiilooyin naxaas ah oo wareegsan ama aluminium iyo fiilooyin, oo ay nashqadeeyeen isbeddelka hadda la qiimeeyay. Waxay ka kooban yihiin{1} qaab dhismeedyo badan oo lakabyo leh oo leh - dahaar tayo sare leh (fasalka F ama H), iyaga oo hubinaya in ay ku sii jiri karaan xaaladaha korantada sare{3}.

 

2.3 Kale

Dabaysha waxaa loo wareejiyaa qolka shubista faakuumka si loogu shubo resin epoxy. Kadib kulaylka hore si looga saaro qoyaanka iyo gaaska, walxaha kiimikaad sida resin epoxy iyo hardeer ayaa lagu diyaariyaa weel kala duwan. Marka la diyaariyo, walxahan waxaa lagu qasi doonaa qasaha taagan ee saamiga saxda ah waxaana lagu tuuraa caaryada. Gariiradaha ayaa markaa lagu daaweeyaa foorno heerkul sare leh si loo abuuro dhismayaal adag oo adag.

epoxy resin winding

 

2.4 Kulanka ugu dambeeya

cast resin dry type transformer final assembly

Harqood sare iyo hoose: Ku hubso harqooyinka sare iyo kuwa hoose ee xudunta beddelka, hubinta xasilloonida iyo waxqabadka korantada.

Isku xirka KorontadaSamee isku xidhka koronto inta u dhaxaysa-voltage iyo hoose- dabaylaha korantada, hubinta in isku xidhku yahay amaan oo buuxiyo shuruudaha naqshadaynta.

Isku-xidhka Dheeraadka ah: Ku rakib qalabyada, sida kantaroolayaasha heerkulka, xirayaasha qalliinka iyo wixii la mid ah, si loo hubiyo guud ahaan daacadnimada iyo shaqeynta dhismaha.

 

 

03 Tijaabinta

Maya

Shayga Tijaabada

Unug

Qiimaha Ogolaanshaha

Qiimaha la qiyaasay

Gabagabo

1

Cabbirka caabbinta dabaysha

/

Qiyaasta dheelitir la'aanta iska caabbinta ugu badan

Iska caabinta khadka: In ka yar ama la mid ah 2%

HV (khadka)

LV (khadka)

Gudub

 

0.05%

1.69%

2

Cabbirka saamiga korantada iyo hubinta barakaca wejiga

/

Dulqaadka saamiga korantada ee taabashada maamulaha: ± 1/10

Astaanta isku xirka: Dyn11

-0.11% ~ 0.24%

Dyn11

Gudub

 

3

Cabbirka Gaaban -Caaqadaha Wareega iyo Luminta Culayska

/

kW

kW

t: 120 digrii

Z%: qiimaha la qiyaasay

Pk: qiimaha la qiyaasay

Pt: qiimaha la qiyaasay

6.21%

13.883

17.849

Gudub

 

4

Cabbirka maya{0}} lumitaanka rarka iyo hadda 90% iyo 110% ee danab la qiimeeyay

/

kW

I0 :: bixiyaan qiime la qiyaasay

P0: bixi qiimaha la qiyaasay

90% Uur

0.207

2.683

Gudub

 

100% Uur

0.23

2.982

110% Uur

0.253

3.280

5

Tijaabada Korantada ee La dabaqay

/

HV: 28kV 60s

LV: 3kV 60s

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

 

6

Tijaabada adkaysiga korantada ee keentay

/

Danab la dabaqay (KV):

2 Uur

Danab la kiciyay (KV): 0.8

Muddada:40

Inta jeer (HZ): 150

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

 

7

Tijaabada Bixinta Qaybeed

pC

Heerka ugu badan ee sii daynta qayb ahaan waa in ay ahaataa 10 pc

<10

Gudub

 

 

dry transformer testing
cast resin dry type transformer testing

 

 

04 Baakaynta iyo dhoofinta

dry transformer packing
dry transformer shipping

 

 

05 Goobta iyo Kooban

Gebagebada, resin caste engegan {{0}nooc transformer waa xal cusub oo ku saabsan injineernimada korantada, isaga oo siinaya hawl qabad la isku halayn karo oo hufan nidaamka qaybinta tamarta casriga ah. Naqshadeeda adag, dahaarka sare, iyo astaamaha badbaadada sare, transformers-yadayada waxaa loo dhisay inay u adkeystaan ​​caqabadaha baahida deegaan iyadoo la hubinayo maaraynta tamarta waxtarka leh. Markaad dooranayso resin castor -nooca transformers, waxa aad galinaysaa xal tayo sare leh oo waara oo kor u qaada waxtarka iyo badbaadada kaabayaasha korantada La kulan faa'iidooyinka teknooloojiyadayada horumarsan oo kor u qaad hababkaaga awoodda doorasho la isku halayn karo oo hufan.

dry transformer

 

Hot Tags: Transformer qalalan, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha