630 kVA Cast Coil Transformer-6.6/0.55 kV|Koonfur Afrika 2025

630 kVA Cast Coil Transformer-6.6/0.55 kV|Koonfur Afrika 2025

Dalka: Koonfur Afrika 2025
Awoodda: 630 kVA
Voltage: 6.6/0.55kV
Sifada: oo leh heerkulka xakamaynta iyo taageereyaasha
U dir sooji

 

 

630 kVA cast coil transformer

Beddelka Nooca Qalalan ee Resin - Ololka - Adayga, Xalka Tamarta Aamusan!

 

 

01 Guud

1.1 Sharaxaada Mashruuca

630 kVA nooc qalalan ayaa la geeyey Koonfur Afrika sanadka 2025. Awooda lagu qiimeeyey transformerku waa 630 kVA oo leh ONAN/ONAF qaboojin. Korantada aasaasiga ah waa 6.6 kV oo leh ± 2 * 2.5% garaacista (NLTC), korantada labaad waa 0.55 kV, waxay sameeyeen koox vector ah Dyn11.

Beddelka Nooca Qalalan ee Cast Resin waa goyn{0}} xal koronto oo loogu talagalay badbaadada sare, hufnaanta, iyo isku halaynta. Si ka duwan sida saliid dhaqameedka -Transformers-ka buuxa, waxay isticmaashaa olol- resin epoxy resin si uu u daboolo dabaylaha, isaga oo meesha ka saaraya khatarta saliida daadato, dabka, iyo khataraha deegaanka.

Ku habboon rakibaadda gudaha, transformers-yadani waxay u shaqeeyaan aamusnaan, waxay u baahan yihiin dayactir yar, waxayna aad ugu adkaystaan ​​qoyaanka, boodhka, iyo bay'adaha daxalka.

Deganaanshiyo heerkuleed oo heer sare ah iyo is-daminta guryaha, waxay xaqiijiyaan awoodda aan kala go' lahayn ee codsiyada muhiimka ah sida dhismayaasha ganacsiga, isbitaallada, xarumaha xogta, iyo dhirta warshadaha. Doorashada Qalalan Nooca Qalalan ee Cast waxay ka dhigan tahay maalgelinta nadiif, deegaan{2} saaxiibtinimo, iyo nidaamka qaybinta tamarta waarta ee mudnaanta siiya badbaadada iyo waxqabadka.

 

 

 

1.2 Tilmaamaha Farsamada

630 kVA nooca qalalan ee tafatirka iyo xaashida xogta

loo geeyey
Koonfur Afrika
Sannadka
2025
Nooca
Transformer nooca qalalan
Qalabka muhiimka ah
xaashi bir silikoon ku jihaysan hadhuudhka
Heerka
IEC60076
Awood lagu qiimeeyay
630kVA
Soo noqnoqoshada
50HZ
Kooxda Vector
Dyn11
Marxaladda
3
Nooca qaboojinta
ONAN/ONAF
Korantada aasaasiga ah
6.6kV
Voltage Secondary
0.55kV
Qalabka dabaysha
Aluminium
Caqabada
6%
Taabo Beddelka
NLTC
Riixista Range
± 2 * 2.5% @ dhinaca hore
Wax Xamuul ah ma jiro
1.3KW
Load Lumista
6.5KW

 

 

1.3 Sawirro

630 kVA kabka resin qalalan nooca transformer jaantus sawir iyo cabbir.

630 kVA cast resin dry type transformer drawing

 

 

02 Wax-soo-saarka

2.1 Core

Transformer-ka nooca xudunta u ah waxaa lagu dhisay - qabow daa'im ah -laminations bir silikoon duuban oo talaabo{2}}qaabaynta isku xidhka dhabta ah si loo yareeyo xiiq-dheerta iyo khasaaraha hadda jira. Qaab dhismeedka Nooca Muhiimka ah wuxuu xaqiijiyaa xitaa qaybinta dabaysha iyo kulaylka la xoojiyey. Iyada oo leh dahaarka ka-hortagga dahaarka{5}, waxay keentaa hawlgal xasilloon, kor u kaca heerkulka hooseeya, iyo hufnaanta tamarta oo la roonaaday si loo helo waxqabad la isku halayn karo.

630 kVA cast coil transformer iron core

 

2.2 Dabaylaha

epoxy resin windings

Transformer-ku waxa uu leeyahay dabaylaha resin epoxy, isaga oo hubinaya dahaarka sare iyo xoogga farsamada. Dabaylaha HV/LV waxay ka samaysan yihiin kirishbooyada aluminiumka oo leh dahaarka dhexda si loo xoojisto xoogga dielectric. Busheska ku jira transformer-ka ayaa lagu rakibay terminalka dabeylaha si loo helo isku xir koronto oo sugan iyo dayactir fudud. Dabayshu waa qoyaan -cadayn iyo boodh - adkaysi u leh, oo ku habboon bay'adaha qallafsan.

 

2.3 Kulanka ugu dambeeya

Transformer-ku waxa uu qaataa nakhshad horumarsan, oo sita epoxy{0}}resin kabka dabaylaha iyo tilaabada{1}}kumbuyuutarku oo lagu ururiyey xadhkaha daboolka beddelka ee la xoojiyay. Unuggu wuxuu isku daraa kontaroolaha heerkulka caqliga leh iyo taageerayaasha qaboojinta kuwaas oo si toos ah u hagaajiya socodka hawada iyadoo lagu saleynayo xaaladaha culeyska. Iyada oo si buuxda u dahaaran, daxalka{4}}Bushings iyo terminal adkaysi u leh, furnaantiisa - qaab dhismeedkiisa qaab dhismeedka hawo-mareenka la hagaajiyay waxa uu xaqiijiyaa kala daadinta kulaylka hufan ee hawlgalka lagu kalsoonaan karo ee hoos yimaada xaalado kala duwan.

630 kVA cast coil transformer assembly

 

 

03 Tijaabinta

Maya

Shayga Tijaabada

Unug

Qiimaha Ogolaanshaha

Qiimaha la qiyaasay

Gabagabo

1

Cabbirka caabbinta dabaysha

/

Qiyaasta dheelitir la'aanta iska caabbinta ugu badan

Iska caabinta khadka: In ka yar ama la mid ah 2%

HV (khadka)

LV (khadka)

Gudub

0.06%

0.61%

2

Cabbirka saamiga korantada iyo hubinta barakaca wejiga

/

Dulqaadka saamiga korantada ee taabashada maamulaha: ± 1/10

Astaanta isku xirka: Dyn11

-0.02% ~ 0.16%

Dyn11

Gudub

3

Cabbirka Gaaban -Caaqadaha Wareega iyo Luminta Culayska

/

kW

kW

t: 120 digrii

Z%: qiimaha la qiyaasay

Pk: qiimaha la qiyaasay

Pt: qiimaha la qiyaasay

6.02%

4.55

6.28

Gudub

4

Cabbirka maya{0}} lumitaanka rarka iyo hadda 90% iyo 110% ee danab la qiimeeyay

/

kW

I0:: bixiyaan qiime la qiyaasay

P0: bixi qiimaha la qiyaasay

90% Uur

0.414

0.985

Gudub

100% Uur

0.46

1.095

110% Uur

0.506

1.204

5

Tijaabada Korantada ee La dabaqay

/

HV: 20kV 60s

LV: 3kV 60s

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

6

Tijaabada adkaysiga korantada ee keentay

/

Danab la dabaqay (KV):

2 Uur

Danab la kiciyay (KV): 1.1

Muddada:40

Inta jeer (HZ): 150

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

7

Tijaabada Bixinta Qaybeed

pC

Heerka ugu badan ee sii daynta qayb ahaan waa in ay ahaataa 10 pc

<10

Gudub

 

630 kVA cast coil transformer testing
630 kVA cast coil transformer test

 

 

04 Baakaynta iyo dhoofinta

4.1 Xirxirida

Transformer-ka Nooca Qalalan ee Cast Resin waxa si sugan loogu soo xidhay - sanduuqyo alwaax ah oo culays ah, oo bixiya ilaalin adag inta lagu jiro gaadiidka iyo kaydinta.

Birta{0}} cidhifyada la xoojiyay waxay kor u qaadaan iska caabinta saamaynta, halka barkinta caadadu ay ilaalinayso xudunta iyo dabaylaha. Calaamadaha dibadda (xarunta cuf-isjiidadka, digniinaha qoyaanka, dhibcaha qaadista) waxay u hoggaansamaan heerarka saadka ee caalamiga ah.

630 kVA cast coil transformer packing

 

4.2 dhoofinta

630 kVA cast coil transformer shippment

Transformer-ka waxaa lagu soo raray shuruudaha CIF (Qiimaha, Caymiska & Xamuulka) iyadoo laga soo qaadayo dekedaha waaweyn ee Shiinaha ilaa Durban, Koonfur Afrika. Gaadiidka transformerka waxaa ku jira caymis buuxa oo badeed ah oo daboolaya wadarta qiimaha xamuulka. Adeegyada soo gudbinta xamuulka ee xirfadleyda ah ayaa lagu bixiyaa nadiifinta kastamka iyo kormeerka dekedda loo socdo.

Soo qaadis degdeg ah markaad timaaddo ayaa lagula talinayaa si looga hortago kharashka dhimista.

 

 

05 Goobta iyo Kooban

Xalka la isku halayn karo ee nidaamyada tamarta, Cast Resin Dry Type Transformer waxa uu la soo baxay saliidiisa{{0}naqshadeeda bilaashka ah, iska caabbinta dabka, ilaalinta qoyaanka, iyo dayactirka{1}} hawlgalka bilaashka ah, taas oo ka dhigaysa mid ku haboon dhismayaasha ganacsiga, dhirta warshadaha, iyo codsiyada tamarta la cusboonaysiin karo. Iyada oo la adeegsanayo injineernimada saxda ah iyo xakamaynta tayada adag, cutub kastaa wuxuu bixiyaa hufnaan sare, badbaado, iyo cimri dherer.

Markaad na doorato, waxaad helaysaa kaliya alaab sare laakiin sidoo kale taageero farsamo oo khabiir ah iyo adeeg iibka kadib-. Faahfaahinta farsamada ama xalalka la habeeyey, la xidhiidh kooxdayada injineernimada maanta!

630 kVA cast coil transformer with temperature controller and fans

 