630 kVA 3 Wajiga Qalalan Nooca Beddelka-6.6/0.55 kV|Koonfur Afrika 2025

630 kVA 3 Wajiga Qalalan Nooca Beddelka-6.6/0.55 kV|Koonfur Afrika 2025

Dalka: Koonfur Afrika 2024
Awoodda: 630kVA
Voltage: 6.6/0.55kV
Muuqaalka: Heerka dahaarka H
U dir sooji

 

 

630 kVA 3 phase dry type transformer

Naqshado Hal abuur leh oo Mustaqbalka Cagaaran: Dooro Resin Cast -Nooca beddelayaasha!

 

01 Guud

1.1 Asalkii Mashruuca

Transformer-ka qallalan ee 630 kVA resin ayaa la geeyey Koonfur Afrika 2024; Awoodda lagu qiimeeyay is-beddelka waa 630 kVA. Korontada sare ee nooca qalalan ayaa ah 6.6 kV, tamar yarna waa 0.55 kV. Qalabkan nooca qallalan ee tamarta sare leh waxa uu ku qalabaysan yahay beddelka tuubada culayska, cabbirka taabashadu waa ± 2 * 2.5% dhinaca hoose. Qaboojintu waa KNAF, waxay samaysteen koox ka kooban Dyn11.

Resin tuuray qalajiyey{0}noca Transformers ayaa hogaaminaya qaabaynta transformerka, iyaga oo siinaya isku dhafka ugu fican ee waxqabadka korantada iyo farsamada Dhismahooda waara, ee lagu gaaro dabaylaha dabaylaha ee resin epoxy, waxay soo bandhigaan xoog iyo badbaado farsamo oo aan isbarbardhigi karin, lama huraan u ah buuxinta yoolalka deegaanka iyo waaritaanka.

Naqshadeeyey bay'ada qallafsan, eco{0}transformers-saaxiibtinimo waxay ka kooban tahay {{1} dayactirka, saliid{2}} nashqada bilaashka ah ee yaraynaysa kharashaadka hawlgalka Ololkooda- dib u dhac, iskood - deminta dahaarka waxay hubisaa heerarka badbaadada sare, halka nashqada is haysta ay badbaadinayso meel lagu rakibo oo qiimo leh.

Anagoo adeegsanayna{0}alaab tayo sare leh oo dahaadhyo ah iyo dhismayaal gariirad adag leh, resinkeena ayaa tuuraya qalalan{1}}nooca transformers waxa uu keenaa isku hallayn iyo adkeysi aad u fiican. U dooro transformers-yadayada si aad u hesho xalal hufan, badbaado, iyo waara oo awood ah kuwaas oo ku siinaya tartan tartan ee nidaamyada tamarta casriga ah.

 

 

1.2 Tilmaamaha Farsamada

630 kVA resin tuurista nooca qalalan qeexitaanka iyo xaashida xogta

loo geeyey
Georgia
Sannadka
2024
Nooca
Transformer nooc qalalan oo shub ah
Qalabka muhiimka ah
xaashi bir silikoon ku jihaysan hadhuudhka
Heerka
IEC60076
Awood lagu qiimeeyay
630kVA
Soo noqnoqda
50 HZ
Kooxda Vector
Dyn11
Marxaladda
3
Nooca qaboojinta
KNAN/KNAF
Korantada aasaasiga ah
6.6 kV
Voltage Secondary
0.55 kV
Qalabka dabaysha
Aluminium
Caqabada
4.5%
Taabo Beddelka
NLTC
Riixista Range
± 2 * 2.5% @ danab hoose
Wax Xamuul ah ma jiro
1.3KW
Load Lumista
5.96KW
Heerka dahaarka
H

 

1.3 Sawirro

630 kVA resin tuuray jaantuska jaantuska qalalan nooca qalalan.

630 kVA resin cast dry type transformer drawing

 

02 Wax-soo-saarka

2.1 Core

Xudunta Transformer-ka waxa laga dhisay -tayo, qabow{1}}duuban, hadhuudh{2}} bir silikoon ku jihaysan oo leh talaabo{3}}labada laabatooyinka si loo yareeyo khasaaraha tamarta Waxay ka kooban tahay saddex lugood oo hal diyaarad lagu habeeyay oo ay isku xidhan yihiin harqood adag. Lug kastaa waa wareeg iyo isku xidhan yihiin harqood, halka xudunta udub dhexaad u tahay xagal 45-degree si loo yareeyo buuqa iyo khasaaraha. Waa la dahaadhay oo laga ilaaliyay daxalka leh dahaarka resin.

Jidhku waxa uu ka kooban yahay kanaalada birta ee sare iyo kuwa hoose ee haya xudunta iyo gariiradaha, iyada oo dhammaan qaybaha birta lagu dahaadhay daxal -Rinji epoxy adkaysi u ah cimri dhererka. Naqshadeyntani waxay xaqiijinaysaa hawlgal hufan iyo isku halaynta xaalado kala duwan.

630 kVA 3 phase dry type transformer iron core

 

2.2 Dabaylaha

630 kVA 3 phase dry type transformer winding

Dhismaha dabaysha ayaa leh astaamo sare {{0}daraasayaal dahaaran oo heerkoodu sareeyo oo loo habeeyey qaybo iyo lakabyo badan si loo dhimo tamarta ugu badan ee ku meel gaadhka ah. Dabaylaha sare - danabyada korantada ayaa lagu tuuraa caaryada faakuumka iyadoo la isticmaalayo kombuyuutar horumarsan -nidaam la kantaroolo, iyadoo la hubinayo in aanay banaanayn gariiradaha.

Dabaylaha waxaa lagu sii xoojiyaa muraayadaha fiberglas si kor loogu qaado xoogga farsamada. Ka dib marka la isku yimaado, dhammaan gariiradaha sare -Voltage-ga ayaa mara tijaabada dheecaanka qayb ahaan si loo xaqiijiyo madhan-xaaladaha xorta ah oo loo hubiyo-waxqabad tayo sare leh. Nashqadan taxadar leh waxay dammaanad qaadaysaa adkeysiga iyo isku halaynta jawiga baahida badan.

 

2.3 Kulanka ugu dambeeya

Rakibaadda gariiradda: Xabagta la tijaabiyay - dabaylaha shubka ayaa si taxadir leh loo dhex dhigayaa qaab beddelka, iyadoo la hubinayo toosinta saxda ah.

Isdhexgalka Muhiimka ahDabaylaha ayaa si ammaan ah loogu dhejiyaa xudunta u ah si loo yareeyo walbahaarka loona hubiyo xasilloonida.

Isku xirka KorontadaXidhiidhada korantada waxaa lagu aasaasay si sax ah, isku xidhka dabaylaha iyo terminalka transformer-yada iyo hubinta isdhexgalka saxda ah ee nidaamka korontada.

Daadinta xabagta: {{0}tayada sareeysa ee epoxy resin ayaa lagu shubay kulanka, isaga oo ka ilaalinaya qoyaanka iyo kor u qaadida dahaarka.

Habka DaawayntaTransformer-ku waa la daaweeyay si uu u adkeeyo xabagta, isaga oo hubinaya qalabka farsamada iyo korantada ee la rabo.

630 kVA 3 phase dry type transformer assembly

 

 

03 Tijaabinta

Maya

Shayga Tijaabada

Unug

Qiimaha Ogolaanshaha

Qiimaha la qiyaasay

Gabagabo

1

Cabbirka caabbinta dabaysha

/

Qiyaasta dheelitir la'aanta iska caabbinta ugu badan

Iska caabinta khadka: In ka yar ama la mid ah 2%

HV (khadka)

LV (khadka)

Gudub

 

0.41%

0.44%

2

Cabbirka saamiga korantada iyo hubinta barakaca wejiga

/

Dulqaadka saamiga korantada ee taabashada maamulaha: ± 1/10

Astaanta isku xirka: Dyn11

-0.14% ~ 0.07%

Dyn11

Gudub

 

3

Cabbirka Gaaban -kahortagga wareegga wareegga iyo luminta culayska

/

kW

kW

t: 120 digrii

Z%: qiimaha la qiyaasay

Pk: qiimaha la qiyaasay

Pt: qiimaha la qiyaasay

4.5%

3.98

5.456

Gudub

 

4

Cabbirka maya{0}} lumitaanka rarka iyo hadda 90% iyo 110% ee danab la qiimeeyay

/

kW

I0:: bixiyaan qiime la qiyaasay

P0: bixi qiimaha la qiyaasay

90% Uur

0.477

1.029

Gudub

 

100% Uur

0.53

1.144

110% Uur

0.583

1.258

5

Tijaabada Korantada ee La dabaqay

/

HV: 20kV 60s

LV: 3kV 60s

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

 

6

Tijaabada adkaysiga korantada ee keentay

/

Danab la dabaqay (KV): 2 Ur

Danab la kiciyay (KV): 1.1

Muddada:40

Inta jeer (HZ): 150

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

 

7

Tijaabada Bixinta Qaybeed

pC

Heerka ugu badan ee sii daynta qayb ahaan waa in ay ahaataa 10 pc

<10

Gudub

 

 

630 kVA 3 phase dry type transformer testing
630 kVA 3 phase dry type transformer factory test

 

 

04 Baakaynta iyo dhoofinta

630 kVA 3 phase dry type transformer packing
630 kVA 3 phase dry type transformer shipping

 

05 Goobta iyo Kooban

Transformerkeena nooca qallalan ee kabka resin waa xal awood hufan oo la isku halayn karo oo loogu talagalay in lagu buuxiyo{0}baahida waxqabadka sare ee codsiyada warshadaha iyo ganacsiga. Lagu sameeyay{2}resin epoxy sare oo la isticmaalayo habka shubista hufan, transformer kasta waxa uu maraa tijaabin adag si loo hubiyo dahaarka korantada ee gaarka ah iyo iska caabinta qoyaanka. Transformers-yadayadu waxay ka kooban yihiin sifooyin maaraynta kulaylka oo aad u wanaagsan, awoodna u siinaya hawlgal xasiloon xaalado deegaan oo kala duwan iyadoo la dhimayo kharashka dayactirka iyo kordhinta cimriga qalabka. Naqshadaynta isku dhafan iyo waxqabadka ilaalinta sare ee resin cast transformer nooca qalalan ayaa ka dhigaya doorasho ku habboon nidaamyada tamarta casriga ah, hubinta gudbinta tamar badbaado leh oo hufan. Dooro transformers-yadayada si aad u dammaanad qaaddo shaqada joogtada ah ee hufan ee nidaamkaaga koronto.

630 kVA 3 phase resin cast  dry type transformer

 