650 KVA Cast Coil Transformers-11/0.34 KV|Imaaraadka Carabta 2025

650 KVA Cast Coil Transformers-11/0.34 KV|Imaaraadka Carabta 2025

Dalka la geynayo: Imaaraadka Carabta 2025
Awoodda: 650kVA
Voltage: 11000/340V
Muuqaalka: oo leh lifaaq IP20
U dir sooji

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha ugu kalsoonida badan iyo alaab-qeybiyeyaasha 650 kva cast transformers-11/0.34 kv|Imaaraadka Carabta 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

 

650 KVA Cast Coil Transformers

Tamar xasiloon codsi kasta - dooro beddelaadaha gariiradda scotech

 

 

01 Guud

1.1 Sharaxaada Mashruuca

650 kVA Cast Resin Dry -Nooca Beddelka Raac heerarka IEC Muujinaya danab wax-soo-galin ah oo ah 11kV iyo danab wax-soo-saar ah oo ah 0.34 kV, oo leh qiime koronto ah 650 kVA. Muujinaya hadhuudh -Ujeedka birta silikoon ku jihaysan iyo dabaylaha naxaasta ah, transformerku wuxuu u shaqeeyaa si badbaado leh isagoo hubinaya nolosha adeeg dheer. Kooxda Yd11 vector waxay bixisaa dhibco dhexdhexaad ah iyo saddex dheeli tiran -wax soo saar weji ah, oo taageeraya sahayda danab joogta ah.

Transformer-ku waxa uu isticmaalaa qaboojinta AN/AF iyo F{0}}dahaarka fasalka, taas oo u oggolaanaysa inuu si badbaado leh ugu shaqeeyo culaysyo kala duwan. Malaha - lumintiisa waa 1.25 kW iyo rarka luminta waa 7.3 kW, taas oo ka caawisa dhimista isticmaalka tamarta. NLTC (Maya-Beddelka Tabaha) ee leh ± 2×2.5% hagaajinta waxay ilaalinaysaa tamarta soosaarka mid joogto ah.

 

 

 

1.2 Tilmaamaha Farsamada

650kVA Resin tuurista nooca qalalan qeexitaanka iyo xaashida xogta

loo geeyey
Imaaraadka Carabta
Sannadka
2025
Nooca
Transformer nooc qalalan oo shub ah
Qalabka muhiimka ah
xaashi bir silikoon ku jihaysan hadhuudhka
Heerka
IEC
Awood lagu qiimeeyay
650kVA
Soo noqnoqoshada
50HZ
Marxaladda
Saddex
Kooxda Vector
Yd11
Nooca qaboojinta
AN/AF
Korantada aasaasiga ah
11KV
Voltage Secondary
0.34 kV
Qalabka dabaysha
Copper
Caqabada
6%
Taabo Beddelka
NLTC
Riixista Range
± 2 * 2.5% @ danab hoose
Wax Xamuul ah ma jiro
1.25 kW
Load Lumista
7.3 kW
Heerka dahaarka
F
Agabka
Xakamaynta heerkulka, taageerayaasha qaboojinta, xidhidh

 

1.3 Sawirro

650kVA Resin wuxuu tuuray cabbirka beddelka nooca qalalan iyo faahfaahinta miisaanka

650 KVA Cast Coil Transformers drawing 650 KVA Cast Coil Transformers nameplate

 

 

02 Wax-soo-saarka

2.1 Core

Xudunta udub dhexaadkayaga nooca qallalan waxa lagu sameeyay hadhuudh{1}} xaashiyo bir ah oo silikoon ku jihaysan. Waxay adeegsataa tilaabo{3}}naqshad wadajir ah ee dhabta ah oo leh 45 digrii, dalool -laminations bilaash ah. Naqshadani waxay hoos u dhigtaa wax - lumitaanka rarka waxayna sidoo kale yaraynaysaa qaylada Transformer-ku wuxuu u socdaa si deggan oo xasilloon.

 

2.2 Dabaylaha

Gariiradaha 650 kVA ee kabka ah waxay ka samaysan yihiin -maxaas hab-dhaqanka sare leh, oo siinaya xoog farsamo sare leh iyo{2}} iska caabin wareeg ah oo gaaban. Dabayshu waxay isticmaashaa dahaarka Heerka F (155 digrii) oo waa epoxy{5}loo shubay si looga ilaaliyo la isku halayn karo ee ka dhanka ah qoyaanka, boodhka, iyo wareegyada gaaban, iyada oo la hubinayo{6}} hawlgal badbaado iyo degganaansho leh.

650 kVA cast coil transformers coils

 

2.3 IP20 Xidhmada

IP20-rated protective enclosure

Qalabkayaga qallalan ee gudaha {{0}noocyada nooca gudeedku waxa ay wataan IP20{2}}lagu qiimeeyay xayndaab ilaalineed, oo bixisa ilaalin dhamaystiran: kahortaga xidhiidhka shilalka ah ee qaybaha korantada sare-, go'doominta siigada iyo walxaha shisheeye, iyo fidinta nolosha adeega transformerka. Xerada kuxiran waxay kaloo yaraynaysaa qaylada shaqada waxayna xoojisaa raaxada shaqada gudaha. Naqshadeeda quruxda badan iyo qaabdhismeedkeeda is haysta waxay siisaa macaamiisha badbaado, la isku halayn karo, oo sahlan - si loo ilaaliyo xalka qaybinta awooda

 

2.4 Kulanka ugu dambeeya

Inta lagu jiro kulanka, nooc kasta oo qalalan -Transformer kasta waxa uu ku qalabaysan yahay heerkulka haye iyo PT100 heerkulbeegyo lagu dhex dhisay saddexda{2}} Kuwani waxay la socdaan heerkulka dabaylaha wakhtiga dhabta ah waxayna ku soo bandhigaan bandhig dhijitaal ah. Lix taageere oo qaboojin heer sare ah- waxay hagaajiyaan daadinta kulaylka waxayna xaqiijiyaan - hawlgal xasiloon muddada dheer. Alaab kastaa waxa ay martaa baadhitaano iyo baadhitaano aad u adag oo badan inta lagu jiro habka wax soo saarka waxaana si fiican mar labaad loo baadhaa ka hor inta aan la rarin. Waxaa naga go'an inaan siino macaamiisha la'isku halayn karo, badbaado leh, oo tayo sare leh{9}}qaab qallalan{10}oo ah nooca beddelka.

650 kva cast coil transformers activepart

 

 

03 Tijaabinta

Imtixaanka Heerka iyo Imtixaanka Joogtada ah

IEC 60076-1-2011 Transformers Power - Qaybta 1: Guud
IEC 60076-3-2013 Transformers Power - Qeybta 3: Heerarka dahaarka, tijaabooyinka dielectric iyo nadiifinta dibadda ee hawada
IEC 60076-11-2018 RLV Transformers Power - Qaybta 11: Nooc qalalan

1. Cabbirka caabbinta dabaysha
2. Cabbirka saamiga korantada iyo hubinta barakaca wejiga
3. Cabbirka gaaban -cidhiidhiga wareegga wareegga iyo rarka luminta
4. Cabbirka aan rarka lumin iyo hadda
5. Tijaabada danabka la dabaqay
6. Imtixaanka adkaysiga danabku keenay
7. Tijaabada dheecaanka qaybeed

650 kva cast coil transformers test-1
650 kva cast coil transformers test-2

04 Baakaynta iyo dhoofinta

650 KVA Cast Coil Transformers packing
650 KVA Cast Coil Transformers transportation

 

05 Goobta iyo Kooban

650 kVA Cast Resin Dry-Type Transformer

Qalabka Qalalan ee Scotech 650 kVA Cast Resin -Nooca Transformer-ka waxa uu keenaa awood aamin ah oo degan codsiyada warshadaha iyo ganacsiga. Waxay leedahay xudunta birta silikoon iyo dabaylaha naxaasta ah oo si buuxda ugu daboolan resin epoxy, taasoo u oggolaanaysa - hawlgal muddo dheer ah oo aan saliid lahayn.

Transformer-ku waxa uu leeyahay kooxda Yd11 vector iyo Maya -Load Tap Changer (NLTC) si uu korantadu ugu sii taagnaado rarka beddelka. Qaboojinta AN/AF iyo dahaarka heerka F waxay u oggolaanayaan inay si badbaado leh ugu socoto heerkul sare. Maya yar -Culqulaha iyo rarka luminta waxay caawiyaan dhimista isticmaalka tamarta.

Xerada IP20 waxay dadka ka ilaalisaa badbaadada waxayna joojisaa siigada iyo walxaha inay soo galaan. Lagu dhisay -Dareemayaal heerkuleed iyo taageereyaal qaboojintu waxay caawiyaan beddelka si la isku halleyn karo.

 