30 KVA Qalalan Nooca Qalalan-11 / 0.22 KV|Imaaraadka Carabta 2025

30 KVA Qalalan Nooca Qalalan-11 / 0.22 KV|Imaaraadka Carabta 2025

Dalka la geynayo: Imaaraadka Carabta 2025
Awoodda: 30kVA
Voltage: 11/0.22kV
Muuqaalka: Ku-xiran IP20
U dir sooji

Jiangshan Scotech Electrical Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha 30 KVA Qalalan Nooca Qalalan -11/0.22 KV|Imaaraadka Carabta 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

 

30 KVA Dry Type Transformer

Hufnaantu waxay la kulantaa cimri dhererka 30kVA-gayada nooc qalalan

 

01 Guud

1.1 Sharaxaada Mashruuca

Kabka 30 kVA ee is haysta -resin engegan{2}}nooca transformer waxa loogu talagalay qaybinta quwad dhexdhexaad ah iyo mid hooseeya. Waxaa loo farsameeyay beddelka korantada aan kala go 'lahayn ee laga bilaabo 11 kV ilaa 0.22 kV, Transformer-kan waxa uu taageeraa ilaa 30 kVA oo culays ah. Muujinaya nooca Yd11 kooxda vector. Transformer-kan waxa uu ku qalabaysan yahay maya {{10}load tap changer (NLTC) oo leh qiyaas isku hagaajin ah ±2 × 2.5%. Waxay dammaanad qaadaysaa nidaaminta korantada ee adag iyada oo la raacayo isbeddellada degdegga ah, hubinta tayada koronta ee aan kala go'in.

Noocan qalalan -Transformer-ka noocan ahi waxa uu isticmaalaa agab cayriin oo tayo sare leh. Xudunta hoose waxa laga dhisay hadhuudh - bir silikoon ku jihaysan, taas oo yaraynaysa khasaaraha birta oo wanaajisa hufnaanta Dabaysha naxaasta ah ee labaad waxay bixisaa habdhaqan aad u fiican. Sadexaad{6}}Dhibcaha Fasalka F dahaarka waxa uu ogolanaya in lagu shaqeeyo heerkul ilaa 155 digrii , taas oo ka dhigaysa mid ku haboon cimilada kulul sida UAE. Qalab tayo sare leh, nakhshad heersare ah iyo farsamaynta khabiiradu waxay bixiyaan{9}}waxqabad dheer.

Waxtarka iyo Khasaaraha: Transformer-kani ma laha wax - khasaare ah oo ah 0.12 kW iyo lumitaanka 0.75 kW, taas oo yaraynaysa qashinka tamarta iyada oo la ilaalinayo waxqabadka. Xakamaynta 4% ayaa xaddidaysa wakhtiga gaaban{5}}waxana uu ilaaliyaa danab xasiloon marka la rarayo.

 

 

 

1.2 Tilmaamaha Farsamada

30kVA Resin tuuray tafatirka nooca qalalan iyo xaashida xogta

loo geeyey
Imaaraadka Carabta
Sannadka
2025
Nooca
Transformer nooc qalalan oo shub ah
Qalabka muhiimka ah
xaashi bir silikoon ku jihaysan hadhuudhka
Heerka
IEC
Awood lagu qiimeeyay
30kVA
Soo noqnoqoshada
50HZ
Marxaladda
Keli
Kooxda Vector
Ii0
Nooca qaboojinta
AN
Korantada aasaasiga ah
11KV
Voltage Secondary
0.22kV
Qalabka dabaysha
Copper
Caqabada
4%
Taabo Beddelka
NLTC
Riixista Range
± 2 * 2.5% @ danab hoose
Wax Xamuul ah ma jiro
0.12 kW
Load Lumista
0.75 kW
Heerka dahaarka
F
Agabka
Xakamaynta heerkulka, Xidhmada

 

1.3 Sawirro

30kVA Resin wuxuu tuuray cabbirka beddelka nooca qalalan iyo faahfaahinta miisaanka

30 Kva Dry Type Transformer drawing 30 Kva Dry Type Transformer nameplate

 

02 Wax-soo-saarka

2.1 Core

grain-oriented silicon steel core

Naqshadaynta udub-dhexaadka ah - wejiga qallalan{1}}nooca transformer wuxuu isticmaalaa hadhuudh{2}} xaashida birta silikoon ku jihaysan. Waxay ku siinaysaa waxqabad wanaagsan waxayna ilaalisaa unugga mid yar iyo iftiin. Tani waa mid waxtar leh marka boosku xaddidan yahay, sida guryaha, dukaamada yaryar, iyo isticmaalka warshadaha fudud.

 

2.2 Dabaylaha

Gariirada 30kVA ee qallalan{1}noocyada transformer's gariiradda sidoo kale waxay isticmaalaan - daariyaal naxaas ah oo tayo sare leh si loo hubiyo khasaaraha hooseeya iyo xoogga makaanikada ee wanaagsan. Dabayshu waxay isticmaashaa nidaamka dahaarka Heerka F (155 digrii), oo ay weheliso tignoolajiyada tuurista resin-ka ee epoxy, oo siinaya iska caabin heer sare ah oo qoyaanka, boodhka, iyo wareegyada gaaban, hubinta hawlgal xasilloon oo lagu kalsoonaan karo macaamiisha.

30 kVA dry-type transformer's coils

 

2.3 IP 20 Lifaaqa

dry-type transformer IP20 enclosure

Noockeena qalalan {{0}Transformer-ka noocayaga ah waxa uu isticmaalaa xidhid IP20, kaas oo ka hortagaya in walxaha adag ee ka weyn 12.5 mm, sida xidhiidhka shilalka ah ee bini'aadamka ee qaybaha nool, ay soo galaan. Waxay ka ilaalisaa shoogga koronto waxayna hubisaa badbaadada aasaasiga ah, taasoo ka dhigaysa mid ku habboon rakibaadda gudaha ee qalalan{4}}nooca transformers.

 

2.4 Kulanka ugu dambeeya

Qaybaha xudunta u ah ee la sameeyay iyo dabaylaha ayaa la isku keenay, inta lagu gudajiro isku xirka korantada, dahaarka, iyo hagaajinta qaab dhismeedka.
Faakuumka hoostiisa, resin epoxy ayaa lagu shubaa inta u dhaxaysa dabaylaha iyo xudunta, isaga oo samaynaya qaab-dhismeed adag oo la daweeyay.
Ka dib isku-ururinta iyo daaweynta, tijaabooyin taxane ah oo koronto iyo makaanik ayaa la sameeyaa si loo hubiyo in beddelka uu buuxiyo heerarka naqshadeynta iyo badbaadada.

30 Kva Dry Type Transformer active part

 

 

03 Tijaabinta

Imtixaanka Joogtada ah iyo Heerka Imtixaanka

IEC 60076-1-2011 Transformers Power - Qaybta 1: Guud
IEC 60076-3-2013 Transformers Power - Qeybta 3: Heerarka dahaarka, tijaabooyinka dielectric iyo nadiifinta dibadda ee hawada
IEC 60076-11-2018 RLV Transformers Power - Qaybta 11: Nooc qalalan

1. Cabbirka caabbinta dabaysha
2. Cabbirka saamiga korantada iyo hubinta barakaca wejiga
3. Cabbirka gaaban -cidhiidhiga wareegga wareegga iyo rarka luminta
4. Cabbirka aan rarka lumin iyo hadda
5. Tijaabada danabka la dabaqay
6. Imtixaanka adkaysiga danabku keenay
7. Tijaabada dheecaanka qaybeed

 

04 Baakadaha iyo Gaadiidka

Resin cast dry type transformer packing Resin cast dry type transformer transportation

 

05 Goobta iyo Kooban

30 kVA Cast Resin Dry-Type Transformer

The Scotech 30 kVA Cast Resin Dry{{1}Type Transformer waxa uu bixiyaa dhexdhexaad nabdoon oo hufan{2}}ilaa hoose-awood koronto ee guryaha, xafiisyada, dukaamada, dugsiyada, iyo warshadaha yaryar. Waxay leedahay xudunta birta silikoon iyo dabaylaha naxaasta ah oo si buuxda ugu daboolan resin epoxy, waxay u shaqeysaa saliid la'aan, waxayna ku shaqayn kartaa jawi kulul, qoyan, ama boodh leh.
Iyada oo leh Maya{{0}Load Tap Changer (NLTC) ee danab xasilan iyo xidhidh IP20 ee badbaadada, waxay keentaa awood la isku halayn karo oo leh khasaare hoose iyo dahaarka heerka F ee hawlgalka heerkulka sare{2}}.
 

Hot Tags: 30 kva transformer nooca qalalan, saaraha, alaab-qeybiyaha, qiimaha, qiimaha

U dir sooji