75 kVA 3 Wajiga suufka Buur beddelka-24.94/0.208 kV|USA 2024
Awoodda: 75kVA
Voltage: 24.94/0.208kV
Feature: oo leh fiyuuska bayonet

Waxqabad xoog leh, waara oo la isku halayn karo – Saddex- Waji suuf ah{1}}Transformer rakiban, laf dhabarta nidaamyada korantada!
01 Guud
1.1 Asalkii Mashruuca
75 kVA pad ku rakiban transformer ayaa la geeyey Koonfurta Ameerika sanadka 2024. Awooda la qiimeeyay ee transformerku waa 75 kVA oo leh ONAN qaboojin. Korantada aasaasiga ah waa 24.94 / 14.4kV oo leh ± 2 * 2.5% cabirka garaaca (NLTC), danab labaad waa 0.208 / 0.12kV, waxay samaysteen koox vector ah YNyn0, waana loop feed transformer. Alaabtani waxay leedahay sifooyinka cabbirka yar, rakibida fudud iyo dayactirka, qaylada hoose, luminta hoose, kahortaga{12}xatooyada, ilaalinta buuxda, awooda culayska xad dhaafka ah iyo wixii la mid ah. Lagu dabaqi karo aagagga cusub ee la dego, suumanka cagaaran, jardiinooyinka, huteelada saldhigyada, goobaha dhismaha, garoomada diyaaradaha iyo meelo kale. Waxaa la ansixiyay qaab dhismeed madax-banaan oo golaha wasiirada ah, halka sare ee golaha wasiiraduna ay u janjeeraan inay fududeeyaan biyo-mareenno waxtar leh. Qaybaha kala duwan ee furayaasha iyo ilaalinta ayaa la isku dari karaa, taas oo ka dhigaysa qaab-dhismeedka qaab-dhismeed badan, hawl dhammaystiran, waxqabad la isku halleyn karo.
1.2 Tilmaamaha Farsamada
75 KVA tafatirka tafatirka nooca iyo xaashida xogta
|
loo geeyey
Koonfurta Ameerika
|
|
Sannadka
2024
|
|
Nooca
suuf ku rakiban transformer
|
|
Heerka
IEEE C57.12.00
|
|
Awood lagu qiimeeyay
75KVA
|
|
Soo noqnoqoshada
60HZ
|
|
Marxaladda
3
|
|
Nooca qaboojinta
ONAN
|
|
Korantada aasaasiga ah
24.94GRDY/14.4 KV
|
|
Voltage Secondary
0.208GrdY/0.12 KV
|
|
Qalabka dabaysha
Aluminium
|
|
barokaca xagal
YNyn0
|
|
Caqabada
3%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Wax Xamuul ah ma jiro
0.08KW
|
|
Load Lumista
1.27KW
|
|
Agabka
Habaynta caadiga ah
|
1.3 Sawirro
75 KVA suuf ku rakiban jaantuska beddelka sawirka iyo cabbirka.
![]() |
![]() |
02 Wax-soo-saarka
2.1 Core
Saddexda - Nooca tiirka xudunta ah ee saddexda ah waxa sidoo kale loo yaqaan saddexda - wejiga saddex geesoodka ah ee udub dhexaadka u ah nooca, kaas oo lagu sameeyo in lagu daro laba harqood oo dhinac ah (aan lahayn xudunta dabaysha) ee bannaanka saddexda Tani waxay yaraynaysaa dhererka dhammaan qalabka wax beddelka. Sadexda -wajiga shanaad- tiirka xudunta waxa lala barbardhigaa sadexda{1} Dabaylaha marxalad kasta oo danab ah ayaa siday u kala horreeyaan loo dejiyaa saddexda tiir ee xudunta u ah sida uu qabo wejiga, harqoodkuna ma laha dabaylo, sidaa darteed saddex{10} waji shanaad{11}}Transformer ayaa loo sameeyay.

2.2 Dabaylaha

Faa'iidooyinka Siliga -Boogta Sare -Dabaysha Voltage
1. Insulation heer sare ah
2. Isticmaalka Meel Sare
3. Kulayl Wanaagsan
4. Habka Wax-soo-saarka ee bisil
Faa'iidooyinka Faylka -Nabarka Hooseeya{1}}Dabaysha Voltage
1. Khasaaraha iska caabinta oo yaraatay
2. Awood Qaadashada Hadda Sare:
3. La Hagaajiyay{1}Xoogga Wareega
4. Cufnaanta Awoodda Wanaagsan
2.3 Haanta
Taangigu waxa uu ka samaysan yahay bir aan lahayn, kaas oo leh awood wanaagsan iyo adkeysi. Dusha sare ee birta waxa lagu dahaadhay dahaarka ka hortagga{1}daxalka si looga hortago daxalka ay keento saamaynta deegaanka ee dibadda. Qaab dhismeed madax-banaan oo golaha wasiirada ah ayaa la ansixiyay, golaha sare ee golaha wasiiradu waxa ay u janjeeraan in ay fududeeyaan daadinta wax ku ool ah, golaha wasiiradu sidoo kale way fududahay in lagu rakibo qaybo.

2.4 Kulanka ugu dambeeya

1. Rakibaadda Dabaysha: Ku dheji dabaylaha danabkoodu sarreeyo iyo kuwa hooseeya, ku xidh tiirarka, oo hubi dahaarka saxda ah.
2. Dahaarka iyo Tijaabinta: Ku dar walxaha dahaadhka oo samee tijaabooyinka tamarta adkaysiga iyo qayb ka mid ah dareeraha.
3. Isku-xidhka Xirmada: Geli xudunta iyo dabaylaha galka daboolka oo dhammaystir habka xidhidhiyaha.
4. Rakibaadda Agabka: Ku rakib qaybaha lagama maarmaanka ah sida qiyaasaha saliidda, heerkulka heerkulka, iyo fuuq-baxayaasha.
5. Saliid Buuxinta (Saliid -Transformers Immersed): Vakuum buuxi saliidda wax ka beddelka, hagaaji heerka saliidda, oo hubi in aanay hawo hadhin.
03 Tijaabinta
1. Tijaabada iska caabinta DC.
2. Tijaabada caabbinta dahaarka.
3. Cabbirka saamiga korantada iyo kooxda vector.
4. Isha goonida ah ac u adkaysta tijaabada danabka.
5. Tijaabada ac u adkaysta
6. Cabbirka maya - rarka lumin iyo wax rar ah ma jiro.
7. Culayska cabbiraadda iyo xannibaadda.
8. Luminta iska caabinta iyo waxtarka.
9. Imtixaanka shaabadda.


04 Baakaynta iyo dhoofinta


05 Goobta iyo Kooban
Waad ku mahadsan tahay xiisahaaga saddexdayada{{0}wajiga{1}} Sida halbeeg u ah xalalka qaybinta awoodda la isku halayn karo, hufan, iyo caqliga leh, badeecadan waxaa loo aqoonsan yahay waxqabadkeeda aadka u wanaagsan, naqshadeynta adag, iyo hufnaanta tamarta gaarka ah, kasbashada kalsoonida macaamiisha ee warshadaha kala duwan. Haddi ay noqoto deegaan, ganacsi, ama codsiyo warshadeed, waxa naga go'an inaanu bixino adeegyo la habeeyey si ay kaaga caawiyaan inaad dhisto nidaam awood leh oo deggan. Waxaan rajeyneynaa inaan kula shaqeyno si aan u abuurno mustaqbal ifaya oo loogu talagalay xalalka awoodda caqliga leh! Macluumaad dheeraad ah, fadlan xor u noqo inaad nala soo xiriirto, waana ku faraxsanahay inaan ku caawinno!

Hot Tags: 3 weji suuf ah oo ku dhejinaya transformer, saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
75 kVA Pad Mount Transformer-22.86 / 0.208 kV|USA 2024
300 kVA Pad Mount Transformer-12.47 / 0.48 kV|USA 2024
300 kVA suuf - ku rakiban Transformer-34.5/0.208 kV|...
500 kVA Pad Mount Transformer-13.8 / 0.48 kV|USA 2025
750 kVA suuf Ku rakiban Beddelka-13.2/0.48 kV|USA 2024
1500 kVA suuf Ku rakiban Beddelka-34.5/0.48 kV|USA 2024
U dir sooji