2000 KVA Cooper Systems Power Pad Ku rakiban Transformers-33.26/0.48 KV|USA 2025
Awoodda: 2000 kVA
Voltage: 33.26/0.48kV
Feature: oo leh xire
Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha ugu kalsoonida badan iyo alaab-qeybiyeyaasha 2000 kva cooper system power pad ku rakiban transformers{6}33.26/0.48 kv|USA 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

suufka -Transformers: Meesha injineerinka waara uu ku kulmo qaybinta casriga ah.
01 Guud
1.1 Sharaxaada Mashruuca
2000 kVA saddex weji suuf ah oo ku rakiban transformer ayaa la geeyey USA 2025. Awoodda lagu qiimeeyay transformerku waa 2000 kVA oo leh qaboojin KNAN. Korontada sare waa 33.26GrdY/19.203 kV oo leh ±2*2.5% garaacista (NLTC), korantada hoose waa 0.48Y/0.277 kV, waxay sameysteen koox ka kooban YNyn0.
Loogu talagalay in lagu kaydiyo cadceedda, kaydinta tamarta, ganacsiga, iyo xaaladaha qaybinta warshadaha, SCOTECH's nidaamka awooda wada shaqayneed ee korantada ku rakiban transformers-ku waxay isku daraysaa waxqabadka la hagaajiyay iyo isticmaale{0}naqshad dhexe si ay u buuxiso baahiyaha kala duwan ee goobta-. 3{5} wajigeeda 5- xudunta addinka iyo DOE{10}} hufnaanteedu waxay sare u qaadaa ka faa'iidaysiga tamarta, faa'iidada muhiimka ah ee nidaamyada tamarta la cusboonaysiin karo halkaasoo watt kasta lagu tiriyo. Isticmaalka dareeraha FR3 wuxuu baabi'iyaa khataraha dabka iyo khataraha deegaanka, taasoo ka dhigaysa go'aan{11}}doorashada rakibaadda u dhow aagagga la deggan yahay, xarumaha xogta, iyo mashaariicda tamarta cagaaran. La dhisay{12}} xirayaasha qallafsan waxay ka difaacaan transformer-ka xadhkaha korantada{13}} waa inay - lahaadaan sifada suufka dibadda{16}ku rakiban ee daboolaya cimilo aan la saadaalin karin. Dhinaca{18}}kabadhka mitirka ee dul saaran - hawlgallada goobta, laga bilaabo la socodka culayska ilaa hubinta dayactirka, halka budada RAL 9003 ee qurxoon -dhamays cad oo dahaaran ay iska caabiso shucaaca UV, miridhku, iyo daxalka kiimikada, hubinta bilicda iyo shaqaynta muddada dheer. Haddi ay ahaan lahayd beeraha cadceedda ku xidhan ama xarumaha ganacsiga ee magaalooyinka, transformer-kani waxa uu keenaa qaybin koronto oo joogto ah.
1.2 Tilmaamaha Farsamada
2000 kVA nidaamyada korantada ee cooper suuf ku rakiban transformers nooca qeexida xaashida xogta
|
loo geeyey
USA
|
|
Sannadka
2025
|
|
Nooca
suuf ku rakiban transformer
|
|
Heerka
IEEE Std C57.12.34-2022
|
|
Awood lagu qiimeeyay
2000 kVA
|
|
Soo noqnoqoshada
60HZ
|
|
Marxaladda
3
|
|
Quudinta
Loop
|
|
Hore
dhintay
|
|
Nooca qaboojinta
KNAN
|
|
Korantada aasaasiga ah
33.26GrdY/19.203kV
|
|
Voltage Secondary
0.48Y/0.277 kV
|
|
Qalabka dabaysha
Aluminium
|
|
Kooxda Vector
YNyn0
|
|
Caqabada
5.75%
|
|
Waxtarka
99.51%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Wax Xamuul ah ma jiro
1.95 kW
|
|
Load Lumista
13.15 kW
|
1.3 Sawirro
2000 kVA suuf ku rakiban jaantuska beddelka sawirka iyo cabbirka.
![]() |
![]() |
02 Wax-soo-saarka
2.1 Core

Xudunta birta ee nidaamyada korantada cooper ee ku rakiban transformers-ka waxa lagu dhisay{0}qabow tayo sare leh{1}} xaashi bir ah oo silikoon duuban, oo loogu talagalay in lagu yareeyo khasaaraha hadda jira iyo xiiqsanaanta. Waxay ka dhigtaa wareegga magnetic-ka beddelka ee wareegga qulqulka hufan, waxay siisaa taageero farsamo oo dabaysha, waxayna muujisaa dejin habboon si loo hubiyo badbaado, hawlgal xasilloon oo leh hufnaan tamar wanaagsan.
2.2 Dabaylaha
Gariiradda (dabaysha) nidaamyada korantada ee cooper ee ku rakiban transformers waxa ay ka samaysan yihiin kirishbooyayaasha naxaasta/aluminiumka ah ee dhaawacan -Voltage (HV) iyo qaybo hoose -qayb voltaji (LV), oo lagu duuduubay walxo adag oo adag (sida xaashida la dahaadhay) ee go'doominta korantada. Dhaawaca ku wareegsan xudunta, waxa ay u hogaansantaa dahaarka IEEE/heerarka kulaylka (oo la waafajiyay dareeraha- deegaanka la quusiyay), waxa ay hubisaa xasiloonida makaanikada ee ka soo horjeeda rakibaadda/ culayska shaqada, oo waxa ay awood u yeelataa beddelka korantada hufan iyo gudbinta korantada.

2.3 Haanta

Taangiga nidaamyada korantada cooper ee ku rakiban transformers waa xayndaab bir ah oo shaabadaysan oo loogu talagalay bannaanka, dhulka - rakibida heerka Waxa ku jira xudunta iyo isku xidhka gariiradda waxaana ka buuxsamay saliid macdan ama wax ka yar - dareere dielectric ah oo guban kara daboolka iyo qaboojinta. Haangu waa mid adag oo fara-maroojinaysa,{4}} adkaysi u leh, leh-profile hoose, oo sida caadiga ah feedhaha ama jiingadaha si ay u kordhiso xoogga iyo kulaylka. Dhammaan qaybaha nooluhu waxay si ammaan ah ugu xidhan yihiin gudaha, halka dibadda, qolalka qufuli karo ay bixiyaan gelitaanka isku xirka fiilooyinka hoose iyo sare, baadiyaha, iyo qalabka ilaalinta, hubinta badbaadada dadweynaha iyo shaqaalaha tamarta.
2.4 Qaybta Firfircoon
Qaybta firfircoon (ururka xudunta ah) ee nidaamyada korantada cooper ee ku rakiban transformers ee sawirka waa qaybta xudunta u ah: waxa ay ka kooban tahay saddex{0}dabaylo dahaaran (duuban oo lagu duudduubay walxo dahaadhid) oo lagu rakibay xudunta birta ee dahaaran, oo lagu lammaaniyay fiilooyinka rasaasta dahaaran (oo lagu xidhxidhay abaabulka) iyo jir taageero bir ah. Kulankani waa mid go'an oo la dahaaray si loo hubiyo isuduwidda korantada - isuduwidda korantada ee udhaxeysa xudunta iyo dabaylaha, halka hogaamiyaasha kaydka hufnaanta ee isku xidhka qaybaha dibadda, u diyaarinta in lagu rakibo haanta wax beddelka-dhammaan u hoggaansamaya dahaarka korantada iyo heerarka xasilloonida makaanikada.

03 Tijaabinta
suufka -Transformers-ka rakiban waxa lagu mariyaa imtixaano adag oo taxane ah si loo hubiyo isku halaynta iyo badbaadada. Kuwaas waxaa ka mid ah tijaabooyinka joogtada ah ee unug kasta, sida cabbirka caabbinta dahaarka, tijaabooyinka saamiga leexashada, xaqiijinta polarity, iyo maya -cabbirrada rarka/luminta. Intaa waxaa dheer, waxay la marayaan tijaabooyinka dielectric, oo ay ku jiraan danab la dabaqay iyo tijaabooyin suurtagal ah, si loo xaqiijiyo daacadnimada dahaarka. Dhammaan cutubyadu waa inay sidoo kale dhaafaan hubinta farsamada iyo hawlgalka ee qalabka sida beddelayaasha tuubada, iyo sidoo kale hubinta xakamaynta kama dambaysta ah. Imtixaanada nooca, oo ay ku jiraan kor u kaca heerkulka iyo gaagaaban{6}} imtixaanada u adkeysiga wareegga wareegga, ayaa lagu sameeyaa unugyo wakiil ah si loo ansixiyo naqshadda.


04 Baakaynta iyo dhoofinta
4.1 Baakad

Baakadaha nidaamyada korantada cooper ee ku rakiban transformers waxay u hogaansamaan heerarka caalamiga ah iyo mashruuca-sharuudaha gaarka ah, iyadoo la isticmaalayo kiis alwaax ah oo qiiqaysan ama bir la xoojiyey oo leh meelo shoog celin ah oo gudaha ah (xunbo/caag) si loo sugo taangiga, baadiyaha, iyo agabka. Waxaa ka mid ah ilaalinta la shaabadeeyey ee ka dhanka ah qoyaanka/ miridhku, calaamadaynta jaangooyada (calamadaha digniinta, macluumaadka badeecada, "Calaamadaha Joogta ah"/"Shockproof") ee ku dheggan boosaska la cayimay, iyo suun aamin ah oo xasiloon inta lagu jiro safarka, iyadoo la hubinayo in cutubku uu ahaanayo mid sugan ilaa laga keenayo.
4.2 dhoofinta
Gaadiidka DDP ee nidaamyada korantada cooper ee ku rakiban transformers waxay u baahan tahay iibiyuhu inuu si buuxda u qaado masuuliyada adag, aan shoogga lahayn, iyo qoyaanka{0}} baakadaha aan caddayn (ilaalinta xudunta, dabaylaha, taangiga, iyo agabka), dooro gaadiidka badda/dhulka ee ku habboon qalabka culus, dhammaystirka cashuuraha, daboolo dhammaan waajibaadka iyo cashuuraha, u hoggaansamaan IMDG, DOT, iyo iibsashada xeerarka caalamiga ah ee badbaadada leh meesha loo qoondeeyay diyaar u ah -si loo rakibo isticmaalka.

05 Goobta iyo Kooban
Dhanka SCOTECH, suufkayada {{0}Transformers ee ku rakiban waxay u taagan yihiin halbeeg u ah isku halaynta, hufnaanta, iyo tayada injineernimada ee nidaamka qaybinta awooda. Lagu dhisay si buuxda u xidhan, daxal - qaabdhismeed adkaysi u leh iyo tignoolajiyada xudunta u ah luminta oo hooseeya, waxay bixiyaan waxqabad joogto ah, aan kala go' lahayn oo leh dayactirka ugu yar, yaraynta kharashyada hawlgalka iyo wakhtiga dhimista ee meertada noloshooda oo dhan.
Waxaan mudnaanta siinaa saxnaanta iyo dabacsanaanta unug kasta oo aan soo saarno. Laga soo bilaabo qiimeynta korantada ee caadiga ah ilaa astaamaha badbaadada ee la xoojiyay, kooxdayadu waxay si dhow ula shaqeeyaan xalalka farsamada ee la jaan qaadaya tilmaamahaaga farsamo ee saxda ah iyo shuruudaha hawlgalka. Waxaa taageeraya hababka xakamaynta tayada adag iyo dhamaystirka-taageerada iibka ka dib, transformers-yadayadu waxa ay marag u yihiin sida ay nooga go'an tahay in aanu gaadhsiino -qiimaha wakhtiga dheer iyo nabada maskaxda macmiil kasta. U dooro SCOTECH Transformers ee aan la kulmin kaliya heerarka warshadaha-iyaga ayay dejiyaan. Nala wadaag, oo u ogolow khibradayada inay awood u yeelato baahiyahaaga kaabayaasha tamarta ugu muhiimsan.

Hot Tags: Nidaamyada korantada ee iskaashiga ah ee ku rakiban transformers, saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
2500 kVA Ku-badaliyeyaasha Korantada ee Deggan-34.5/...
500 kVA Pad Mount Transformer-13.8 / 0.48 kV|USA 2025
400 kVA Padmount Transformer-23/0.4 kV|Chile 2024
500 kVA Utility Pad Ku rakiban Beddelka-24/0.48 kV|U...
2000 KVA Barta-xarunta Tamarta Ku Rakiban Tamarta-24...
2000 KVA Bayonet Fuse Pad Ku Rakiban Tamashlaha-13.8...
U dir sooji