1500 KVA Qalabka Korantada ee Sanduuqa-12.47 / 4.16 KV|USA 2025

1500 KVA Qalabka Korantada ee Sanduuqa-12.47 / 4.16 KV|USA 2025

Dalka la geynayo: Ameerika 2025
Awoodda: 1500kVA
Voltage: 12.47/4.16kV
Muuqaalka: oo leh UL Liiska
U dir sooji

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha ugu kalsoonida badan ee 1500 kva sanduuqa korantada korantada{6}}12.47/4.16 kv|USA 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

 

1500 kVA electrical transformer box

Sanduuqa koronto ee horumarsan oo loo habeeyay si uu ula kulmo heerarka IEEE iyo UL, hubinta qaybinta awood hufan oo sugan

 

 

01 Guud

1.1 Sharaxaada Mashruuca

1.5 MVA (1500 kVA)saddex{0}} suufka wejiga{1} ku rakibanwaxa uu bixiyaa la isku halayn karo, utility -awood darajo is haysta, faraqaba{1}} xidhid adkaysi u leh. Waxaa loo dhisay si ay ula kulanto IEEE Std C57.12.34-2022, DOE 2016, iyo UL Listed standards. Waxay siisaa xal badbaado leh oo hufan oo dhexdhexaad ah{8}}Nidaamka qaybinta korantada waxayna la socotaa dammaanad 3 sano ah oo loogu talagalay isku halaynta muddada dheer.

Transformer-ku waxa uu leeyahay loop{0}} quudin oo dhintay{1}} nashqada hore. Waxay beddeshaa danab ka 12.47 kV dhinaca aasaasiga ah ilaa 4.16 kV ee dhinaca sare oo leh kooxda Dyn1. Habayntani waxay si fiican ugu shaqaysaa noocyo badan oo shabakadeed. Waxay haysataa shan off{8}} boosaska tuubada wareega (14.4 kV, 13.8 kV, 13.2 kV, 12.47 kV, 12.0 kV) si loo hagaajiyo tamarta hadba goobta loogu baahdo. Waxay isticmaashaa qaboojinta ONAN iyo dahaarka saliidda macdanta. Heerkulka sare u kaca waa 65 darajo . Astaamahani waxay ilaalinayaan transformer-ka mid xasiloon oo kordhiya cimrigiisa adeeg.

Dabaysha aluminiumka ayaa bixisa dheelitirnaanta adkeysiga iyo hufnaanta kharashka, halka 5.75% xannibaadku ay taageerto maaraynta khaladka la isku halayn karo. Lagu tijaabiyay khasaaraha DOE 2016 -maya-luminta 1,545 W iyo culayska luminaya 10,540 W-naqshadu waxay buuxisay tamarta{10}kulaha hufnaanta waxayna yaraynaysaa kharashaadka hawlgalka. Qalabyada caadiga ah waxa ka mid ah fiyuuska bayoneetka oo leh xidhidhyo go'doon ah iyo saddex{12}} gabal, laba{13}}boos jabinta culayska.

Qaybahani waxay ka dhigayaan ilaalinta mid fudud oo hawlgal ammaan ah.

Transformer-ku waa cufan, la isku halayn karo, waana sahlan tahay in la dayactiro. Waa doorasho wanaagsan nidaamyada qaybinta tamarta, goobaha tamarta la cusboonaysiin karo, tas-hiilaadka warshadaha, iyo shabakadaha tamarta kaabayaasha ee America (2025 gaarsiinta).

 

 

 

1.2 Tilmaamaha Farsamada

1500 KVA tafatirka sanduuqa korantada iyo xaashida xogta

loo geeyey
Ameerika
Sannadka
2025
Nooca
Saddex weji suuf Buur Transformer
Heerka
IEEE Std C57.12.34-2022
Awood lagu qiimeeyay
1500KVA
Soo noqnoqoshada
60HZ
Quudinta
Loop
Hore
dhintay
Marxaladda
Saddex
Nooca qaboojinta
ONAN
Insulant dareere ah
Saliidda Macdanta
Korantada aasaasiga ah
12.47 kV
Voltage Secondary
4.16 kV
Kooxda Vector
Dyn1
Qalabka dabaysha
Aluminium
Caqabada
5.75%
Waxtarka iyo khasaaraha Heerka
DOE 2016
Taabo Beddelka
NLTC
Riixista Range
14400, 13800, 13200, 12470, 12000
Wax Xamuul ah ma jiro
1545 W
Load Lumista
10540 W
Agabka
Bayoneti w/ ISO Links, Saddex gabal 2 booska Load Break Break

 

1.3 Sawirro

1500 KVA sanduuqa beddelka korantada sawirka sawirka iyo cabbirka

1500 kVA electrical transformer box drawing

 

 

02 Wax-soo-saarka

2.1 Core

1500 kVA electrical transformer box iron core

Xudunta 1500 KVA korontadu waxay leedahay saddex - addin, tallaabo - nashqada dhabta ah. Waxay ka samaysan tahay hadhuudh -ujeeda, qabow- bir silikoon duuban. Lamination kasta waxaa loo gooyaa si sax ah oo aan lahayn burooyin. Tani waxay gacan ka geysaneysaa hoos u dhigista luminta xudunta waxayna yareysaa buuqa. Lamination-yada waa la is dulsaaray oo si adag ayaa loo xiray si looga fogaado faraqyada hawada. Tani waxay wanaajisaa waxqabadka birlabeedka waxayna ka dhigtaa beddelka mid hufan oo la isku halayn karo.

 

2.2 Dabaylaha

1500 kVA electrical transformer box winding
1500 kva electrical transformer box-transformer-windings

Transformer-ku waxa uu leeyahay silig{0}}dhaawaca sare{1}} gariiradaha hoose ee danabka iyo xaashida{2}} Naqshadani waxay yaraynaysaa diiqada axial ee ay keento wareegyada gaaban waxayna u ogolaataa qaybinta birlabeedka dheellitiran ee isku xirka tuubada. Gariiradaha waxa lagu sameeyaa mashiino saxan oo saxan- kaas oo hubiya xiisad joogto ah iyo meelaynta kirishboyga saxda ah, taasoo siinaysa transformerka xoog gaaban oo gaaban{6}} iska caabin wareeg ah iyo hufnaan sare.

 

2.3 Haanta

Taangiga beddelka wuxuu ka samaysan yahay bir khafiif ah. Way adag tahay oo way fududahay in la xakameeyo, rakibo, oo la ilaaliyo. Haanta waxay leedahay dabool daboolan si loo ilaaliyo dareeraha dahaadhka ah iyo qaybaha gudaha. Birtu waa sax -oo la jarjaray, kulul{4}}la rogmaday, la shiiday, oo la saliiday. Alxanka ayaa hubiya in haanta waarta oo la isku halayn karo.

1500 kVA electrical transformer box oil tank

 

2.4 Kulanka ugu dambeeya

1500 kVA electrical transformer box active part

Thesuufka -ku rakiban qalabkaxudunta iyo isku xidhka gariiradda waxa lagu xidhaa darafyo bir culculus si loo ilaaliyo gariiradaha leydiga ah inay fooraraan inta lagu jiro xaaladaha wareegga gaaban- Taarikada si adag ayaa loogu dhejiyaa madbacooyin ka dibna la alxankayo ​​ama la xidho si ay u sameeyaan qaabdhismeed adag. Shirku waxa uu la kulmay ama ka badan yahay ANSI iyo IEEE gaagaaban{3}} heerarka wareegga. Naqshad adag ayaa ka dhigaysa isbedbeddelka xannibaadda mid yar, oo la mid ah wareegyada{5}} gariiradaha boogaha.

 

 

03 Qaybaha Waaweyn

1500 kva electrical transformer box-Bayonet fuse
Saddex xabbo oo Baynet fiyuus ah
1500 kva electrical transformer box-Load break switch
Saddex xabbo oo daaran jabiya
1500 kva electrical transformer box-200 A HV Bushing
200 A HV Bushing
1500 kva electrical transformer box-Monitoring and Protection Devices
Qalabka la socodka iyo ilaalinta
1500 kva electrical transformer box-Nitrogen Charging Valve & Gas Sampler
Ku dallaca Nitrogen Valve & Gaas Sampler
1500 kva electrical transformer box-4 holes LV Bushing
4 godadka LV Bushing

 

 

04 Tijaabinta

1500 kVA electrical transformer box testing
1500 kVA electrical transformer box factory test

 

 

05 Baakadaha iyo gaadiidka

5.1 Baakad

1500 kva electrical transformer box-packaging
1500 kVA electrical transformer box packing

 

5.2 dhoofinta

1500 kVA electrical transformer box shipping
1500 kva electrical transformer box-delivery

 

Hot Tags: sanduuqa transformer koronto, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha

U dir sooji