750 KVA Pad Mount Transformer Grounding-13.8/0.6 KV|Kanada 2025
Awoodda: 750kVA
Voltage: 13.8/0.6kV
Muuqaalka: Kooxda Vector DD0
Jiangshan Scotech Electric Company kanada 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. nala soo xidhiidh wixii faahfaahin ah

750 kVA Pad Mount Transformer Grounding - Waxaa loogu talagaly ilaalinta khaladka badbaado leh, waxqabadka shabaqlaha deggan, iyo nidaamyada qaybinta dhulka hoostiisa ee la isku halayn karo.
01 Guud
1.1 Sharaxaada Mashruuca
Mashruucani wuxuu ku lug leeyahay keenista a750 kVA saddex -waji suuf ah oo ku dhejiya beddelkailaa Kanada-oo lagu dhisay shuruudaha shahaadiga ah ee UL oo si buuxda ugu hoggaansan heerarka CSA C227.4:21, la beegsanayo{3}} badqabka hawlgelinta muddada dheer, is dhexgalka netka xasilloon, iyo isku halaynta sare ee guud ahaan shabakadaha qaybinta deegaanka, ganacsiga, iyo warshadaha; halkaas oo sii wadida adeegga, iyo adkeysiga qaladka, aysan ahayn ikhtiyaar, laakiin la filayo.
Cutubku wuxuu ku shaqeeyaa qaabaynta quudinta loop oo leh mid dhintay{{0}nakhshad hore{1}} beddelaad badbaado leh, go'doon wanaagsan, dabacsanaan badan nidaamka qaybinta dhulka hoostiisa. Waxay hoos u dhigtaa danab laga bilaabo 13.8 kV ilaa 0.6 kV, samaynta isdhexgal nadiif ah oo deggan oo u dhexeeya dhexdhexaad - isticmaalka korantada ee hooseeya - isticmaalka korantada; habdhaqanka joogtada ah ee hoos yimaada xaaladaha culeyska ee isbeddelaya, xitaa marka dalabku isbeddelo.
Habayntan, suufku waxa uu ku dhejiyaa nakhshad dhul dhigista transformer -ma aha oo kaliya tafaasiil, laakiin qayb qaab dhismeedka nidaamka caqli gal ah{1}wuxuu si toos ah u saameeyaa khaladka maaraynta hadda jirta, xasiloonida hawlgalka, iyo isku xidhka ilaalinta. Gaar ahaan loop{3}}shabakadaha la quudiyo; sii wadida dhulka waa in la hayaa, waa in la hayaa, haddii kale jawaabta nidaamku waxay noqotaa mid aan la saadaalin karin.
1.2 Kooxda Vector & Impedance
Transformer-ku waxa uu isticmaalaa koox-Dd0 vector ah, isaga oo bixinaya barakaca eber iyo iswaafajinta xasilloon ee loop{1}}nidaamyada quudinta, hubinta hawlgalka siman ee isbarbar socda ee shabakadaha dajinta suufka suufka ee heerka 0.6 kV, oo leh waxqabad la isku halayn karo oo ka hooseeya culeysyo dheellitiran iyo kuwa aan dheellitirnayn labadaba.
Xakameynteeda 4.75% waxay bixisaa xaddidaad gaaban oo wax ku ool ah oo hadda jirta waxayna taageertaa xakamaynta korantada deggan, kor u qaadida badbaadada guud iyo xoojinta waxqabadka nidaamka dhulka hoostiisa ee xaaladaha cilladaysan ee CSA C227.4:21 rakibaadyada waafaqsan.
1.3 Tilmaamaha Farsamada
750 kVA suuf ku dhajinta qalabka wax lagu beddelo qeexida iyo xaashida xogta
|
loo geeyey
Kanada
|
|
Sannadka
2025
|
|
Nooca
Saddex weji suuf Buur Transformer
|
|
Heerka
CSA C227.4:21
|
|
Awood lagu qiimeeyay
750KVA
|
|
Soo noqnoqda
60HZ
|
|
Quudinta
Loop
|
|
Hore
dhintay
|
|
Marxaladda
saddex
|
|
Nooca qaboojinta
ONAN
|
|
Insulant dareere ah
Saliidda Macdanta
|
|
Korantada aasaasiga ah
13.8 kV
|
|
Voltage Secondary
0.6 kV
|
|
Kooxda Vector
dd0
|
|
Qalabka dabaysha
Copper
|
|
Caqabada
4.75%
|
|
Waxtarka
99.15%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Wax Xamuul ah ma jiro
1.230 kW
|
|
Load Lumista
8.800 kW
|
|
Agabka
Habaynta caadiga ah
|
1.4 Sawirro
750 kVA suuf ah oo ku dul dhejinaya beddelka sawirka dhulka hoostiisa iyo saxanka magaca
![]() |
![]() |
02 Wax-soo-saarka
2.1 Core

Xuddunta waxa ay ka samaysan tahay bir silikon dahaaran oo tayadeedu sarayso{0} Habka isu-ururinta ayaa dammaanad qaadaya adkeynta farsamada iyo waxqabadka magnetic ugu fiican. Wax soo saarka ka dib, xudunta waxaa lagu duuduubay filim caag ah oo ilaalinaya si looga hortago qoyaanka soo galaya, wasakhowga boodhka, iyo oksaydhka inta lagu jiro kaydinta iyo gaadiidka, ilaalinta waxqabadka xasilloon gudaha nidaamka guud ee kor u kaca qalabka beddelka.
2.2 Dabaylaha
Transformer-ku wuxuu isticmaalaa dabaylaha naxaasta ah oo leh dahaarka saliidda macdanta. Naqshadu waxay taageertaa ± 2 × 2.5% NLTC hagaajinta tuubada, hubinta wax soo saarka korantada deggan ee xaaladaha culeyska kala duwan iyo taageeridda hawlgal lagu kalsoonaan karo oo ku dhex jira shuruudaha naqshadeynta beddelka.

2.3 Haanta

Transformer-ku waxa uu leeyahay haan bir ah oo khafiif ah oo daboolan oo daboolan, ku dhammaatay qalab cagaaran (Munsell 9 GY 1.5/2.6) ee caabbinta daxalka iyo aqoonsiga goobta.
Naqshadeynta muddada dheer- waaritaanka, haanta waxay isku daraysaa qaab dhismeedka dhul-bedelka korka oo dhammaystiran, oo ay ku jirto aaladda cadaadiska, tuubada tuubada saliidda oo leh shaqo muunad, iyo fur buuxin. Baska naxaasta dhulka dhiga ee adag oo leh marinada spade ayaa hubiya arxinta wax ku oolka ah, ilaalinta u hogaansanaanta heerarka badbaadada iyo xoojinta hufnaanta naqshadaynta nidaamka dhulka.
2.4 Bushings & Terminalka
Sare -Voltage (HV) Bushings
Dhinaca HV waxa ay isticmaashaa 3 fur oo dahaaran oo la kala sooci karo{1} oo ku jira xidhiyaal lagu qiimeeyay 200 A, oo lagu rakibay qaybta HV. Iyadoo 95kV BIL, waxay xaqiijiyaan isku xidhka badbaadada iyo la isku halayn karo ee loop{5}}ku-xidhka suufka ku rakiban hababka dhulka, iyagoo siinaya xamaasad adag oo u adkaysan karta iyo hawlgal deggan.


Hoos-u-dhacyo {{0}Voltage (LV)
Dhinaca LV waxa uu leeyahay 3 resin{1}kabka tuurka leh oo leh 4-dalool -nooca terminal, lagu qiimeeyay 30kV BIL, hubinta isku xidhka badbaadsan iyo iska caabinta hoose ee 0.6 kV iyada oo la taageerayo wax qabad degenaansho isbedbedel ah.
Terminalka dhulka
Laba terminaal oo go'an oo leh bas naxaas ah oo adag ayaa xaqiijiya nidaamka dajinta beddelka beddelka oo dhammaystiran, siinta carro-ku-salaysan la isku halayn karo ee labada dhinac ee HV iyo LV, hagaajinta cilladda hadda jirta iyo amniga nidaamka guud.

2.5 Qalabka & Agabka

Transformer-ku waxa uu ku qalabaysan yahay ilaalin dhamaystiran iyo ilaalin, taageerta hawlgalka iyo suufka ku dhejinta qalabka wax-ka-beddelka maamulka badbaadada:
- Qiyaasta heerkulka saliidda ee xakamaynta kulaylka
- Qiyaasta heerka saliidda ee xasilloonida dahaarka
- Qiyaasta cadaadiska Vacuum ee la socodka xaalada gudaha
- Qalabka cadaadiska cadaadiska ee ilaalinta taangiga
- Saliida daadisa oo leh shaqo muunad oo loogu talagalay dayactirka
03 Tijaabinta
Heerarka Imtixaanka

Natiijooyinka Imtixaanka

04 Baakadaha iyo gaadiidka
4.1 Xirxirida


4.2 dhoofinta


05 Rakibaadda Goobta & Kooban
Rakibaadda iyo Hawlgelinta
Rakibaadda waxay raacdaa habraacyada caadiga ah, hubinta meelaynta sugan, isku xirka korantada ee saxda ah, iyo hirgalinta dhul dhigista suufka saxda ah. Guddidu waxay xaqiijisaa daacadnimada dahaarka, sii wadida dhulka, iyo badbaadada hawlgalka oo buuxda ka hor tamarta.
Tilmaamaha Muhiimka ah ee dib u koobista
- Waxtarka sare (99.15%) wuxuu yareeyaa khasaaraha tamarta
- CSA la isku halayn karo-naqshad waafaqaysa oo loogu talagalay - hawlgalka mudada dheer
- Kooxda DD0 vector waxay xaqiijisaa hab-dhaqanka hab-dhaqanka deggan
- Sare -voltage iyo hoose-Bushings voltaji waxay xaqiijiyaan isku xidhka aaminka ah
- Nidaamka dhulka hoostiisa ee qalabka beddelka suufka oo dhammaystiran wuxuu kor u qaadaa badbaadada qaladka iyo xasilloonida nidaamka
- Qalabka kormeerka isku dhafan ee waxtarka dayactirka
Qalabkan 750 kVA{1}ku rakiban yahay is beddelka waa xal aad la isku halleyn karo oo hufan oo loogu talagalay shabakadaha qaybinta casriga ah, keenaya waxqabad koronto oo xooggan, nakhshad dhul-beereed adag, iyo u hoggaansanaanta buuxda ee heerarka amniga Waqooyiga Ameerika.
Hot Tags: suufka ku dheji transformer grounding, saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
2500 kVA Saddex Waji oo suuf ah -Ku rakiban Transfor...
150 kVA suuf Ku rakiban Beddelka-34.5/0.208 kV|USA 2024
500 kVA suuf Ku rakiban Beddelka Korontada-34.5/0.48...
150 kVA Ansi Transformer-24.94/0.208 kV|USA 2024
2000 KVA Bayonet Fuse Pad Ku Rakiban Tamashlaha-13.8...
800 KVA Delta Wye Transformer-34.5/0.48 KV|USA 2025
U dir sooji