50 kVA Beddeleyaasha Cirifka Utility-34.5/0.12*0.24 kV|Kanada 2024
Awoodda: 50kVA
Voltage: 34.5/0.24kV
Muuqaalka: oo leh OCTC

Gudbinta khaaska ah, sahay koronto sax ah - Hal - tiirka wejiga{1} ku rakiban taransfooraha awooda nolol wanaagsan
01 Guud
1.1 Asalkii Mashruuca
Tan 50kVA hal weji hal tiir ku rakiban transformer waxaa loo dhoofiyaa Kanada Julaay, 2024. Awoodda lagu qiimeeyay beddelka nooca qalalan waa 50 kVA, korantada aasaasiga ah waa 34.5 kV iyo danab labaad waa 0.12/0.24 kV. Transformers-yada ay soo saartay shirkadeena waxaa loogu talagalay qaab dhismeedka xudunta u ah birta oo tayo sare leh iyo tamar lagu badbaadinayo. Maaddada xudunta u ah birta waxay ka samaysan tahay xaashi bir silikoon ku jihaysan oo qabow oo tayo sare leh oo ay ku dahaaran tahay oksaydhka macdanta. Iyadoo la xakameynayo habka goynta iyo isu-ururinta xaashida birta silikoon, heerka luminta beddelka iyo maya{9}}load hadda iyo heerka qaylada ayaa la yareeyaa. Intaa waxaa dheer, tignoolajiyada dabaysha ee gaarka ah ee transformer-ku waxay si wax ku ool ah u wanaajisaa iska caabinta hillaaca iyo caabbinta wareegga gaaban{11} Waxaa inta badan loo isticmaalaa shabakada qaybinta ee dhulka miyiga, wax soo saarka beeraha iyo korontada dhismaha rayidka ah iyo nidaamka qaybinta.
Waxaan hubineynaa in mid kasta oo ka mid ah cutubyada nala keenay uu maray imtixaan adag oo aqbalaad ah. Waxaan bixinaa hal{1} adeeg xirmo laga bilaabo la talinta, xigashada, soo saarista, rakibida, hawlgelinta, tababarka ilaa adeegyada iibka kadib, alaabadayadu hadda waxay ka shaqeeyaan in ka badan 50 degmo oo aduunka ah. Waxaan hiigsaneynaa inaan noqono alaab-qeybiyahaaga ugu kalsoonida badan iyo sidoo kale lamaanahaaga ugu fiican ganacsiga!
1.2 Tilmaamaha Farsamada
50 kVA hal waji oo tiir ah oo ku rakiban qeexitaannada beddelka iyo xaashida xogta
|
loo geeyey
Kanada
|
|
Sannadka
2024
|
|
Qaabka
50kVA-34.5-0.12/0.24kV
|
|
Nooca
Tiir hal waji ah oo ku rakiban transformer
|
|
Heerka
IEEE C57.12.20
|
|
Awood lagu qiimeeyay
50kVA
|
|
Soo noqnoqoshada
60HZ
|
|
Marxaladda
Keli
|
|
Nooca qaboojinta
ONAN
|
|
Korantada aasaasiga ah
34.5 kV
|
|
Voltage Secondary
0.12 / 0.24 kV
|
|
Qalabka dabaysha
Aluminium
|
|
Polarity
Kala goyn
|
|
Caqabada
2.5%
|
|
Dulqaad
±7.5%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Insulant dareere ah
Saliida macdanta
|
|
Wax Xamuul ah ma jiro
0.112KW
|
|
Load Lumista
0.5KW
|
|
Agabka
Habaynta caadiga ah
|
1.3 Sawirro
50 kVA tiir ku rakiban jaantuska beddelka sawirka iyo cabbirka.
![]() |
![]() |
02 Wax-soo-saarka
2.1 Core
Sababtoo ah xudunta gariiradda ayaa ku dhaawacantay jihada magnetic ugu fiican ee xaashida birta ee silikoon toosan, waxay si buuxda u siinaysaa ciyaar buuxda waxqabadka sare ee xaashida birta ee silikoon toosan, jihada qulqulka magnetic gabi ahaanba waa la jaan qaada jihada xaashida birta silikoon, awooda culeyska culeysku waa xoog badan yahay, qallooca wareegga magnetic waa yar yahay, markaa maya -luminta birta iyo birta la rakibay ayaa ka yar culeyska birta ah. qallooca wareegga magnetic sababtoo ah wadajirka laminated).

2.2 Dabaylaha

- Dabaysha danab yar oo leh silig xargo ku duuban oo tayo sare leh,
- Dabaysha korantada sare waxa ay ku dhaawacantay -polyurethane tayo sare leh{2}}silig aluminium dhalaalaysan
- Dahaarka interlayer waxa uu isticmaalaa warqad dhibco ah si uu xadhigga ugu xidho unug go'an oo leh iska caabin aad u wanaagsan
- Qaab dhismeedka transformerku waa la isku halayn karo inta lagu jiro hawlgalka caadiga ah iyo gaadiidka
2.3 Haanta
{{0} Japan Mitsubishi laysarka mashiinka goynta iyo CNC feedh, yaraynta, laalaabida iyo qalabka kale si loo hubiyo saxnaanta habaynta
- ABB robot alxanka tooska ah, ogaanshaha laysarka, iska ilaali daadinta, heerka gudbinta 99.99998%
- Daawaynta buufinta korantada, 50 sano kama saarna rinjiga (dahaarka iska caabbinta daxalka gudahooda 100h, engegnaanta Ka weyn ama la mid ah 0.4)
- Nooc silinder ah oo si buuxda loo shaabadeeyey oo leh iskii{1}
- Xakamaynta caadiga ah ee NEMA (cutub kasta waxa ku jira taarikada taageerada tiirka)
- Qaab dhismeedka si buuxda u xidhan, dayactirka{1}} bilaash, nolosha hawlgalka caadiga ah ee ka badan 30 sano

2.4 Kulanka ugu dambeeya


03 Tijaabinta
1. Isku-xidhka oo dhan iyo meelaha taabo
2. Tijaabada Polarity
3. Maya - khasaarooyinka rarka ee 100% lagu qiimeeyay danab la saxay ilaa 85 darajo
4. Hadda xiisaha leh ee 100% danab lagu qiimeeyay
5. Lumitaanka rarka iyo ciribtirka wakhtiga la qiimeeyay oo la saxay ilaa 85 darajo
6. danab la dabaqay
7. danab la kiciyay
8. daadinta taangiga Transformer{1}}baaritaanka ogaanshaha
Natiijada tijaabada
|
Maya |
Shayga Tijaabada |
Unug |
Ogolaanshaha Qiimaha |
Qiimaha la qiyaasay |
Gabagabo |
|
1 |
Cabbiraadaha iska caabinta |
/ |
/ |
/ |
Gudub |
|
2 |
Imtixaanada saamiga |
/ |
Weecashada saamiga danab ee taabashada maamulaha: In ka yar ama la mid ah 0.5% Astaanta isku xirka: Ii0 |
-0.02 |
Gudub |
|
3 |
Tijaabada polarity |
/ |
Kala goyn |
Kala goyn |
Gudub |
|
4 |
Maya- khasaarooyinka rarida iyo xamaasadda hadda |
% kW |
I0 : bixiyaan qiime la qiyaasay P0: bixi qiimaha la qiyaasay Dulqaadka wax qabad la'aan waa ± 15% |
0.32 0.112 |
Gudub |
|
5 |
Khasaaraha culeyska, korantada impedance, wadarta khasaaraha iyo hufnaanta |
/ kW kW |
t: 85 darajo Z%: qiimaha la qiyaasay Pk: qiimaha la qiyaasay Pt: qiimaha la qiyaasay dulqaadka impedance waa ± 10% Dulqaadka wadarta rarka luminta waa ± 8% |
2.60 0.488 0.600 99.12 |
Gudub |
|
6 |
Tijaabada Korantada ee La dabaqay |
/ |
HV: 70KV 60S LV: 10kV 60s |
Ma jiro burbur ku yimaada tamarta tijaabada ah |
Gudub |
|
7 |
Tijaabada adkaysiga korantada ee keentay |
/ |
Danab la dabaqay (KV): 69 Muddada: 48 Inta jeer (HZ): 150 |
Ma jiro burbur ku yimaada tamarta tijaabada ah |
Gudub |
|
8 |
Cabbirka iska caabinta dahaarka |
GΩ |
HV -LV ilaa Dhulka: LV-HV ilaa Dhulka: HV&LV ilaa Dhulka: |
59.3 57.7 56.4 |
/ |
|
9 |
Tijaabada daadinta |
/ |
Cadaadiska la dabaqay: 20kPA Muddada: 12h |
Wax daadsan iyo maya Waxyeello |
Gudub |
|
10 |
Tijaabada Saliida |
kV, mg/kg, %, mg/kg, |
Xoogga Dielectric; Nuxurka qoyaanka; Qodobka Burburinta; Falanqaynta Furan; Falanqaynta Chromatography ee Gaaska |
50.8 9.6 0.00437 0.03 / |
Gudub |

04 Baakaynta iyo dhoofinta
![]() |
![]() |
05 Goobta iyo Kooban
Waad ku mahadsan tahay xiisahaada - tiirka wejiga -ku rakiban transformerka! Iyada oo hufnaanteeda, xasilloonida, iyo cimri dhererkeeda, badeecadani waxay bixisaa taageero lagu kalsoonaan karo oo loogu talagalay gudbinta awoodda waxayna u adeegtaa sidii qayb muhiim ah oo ka mid ah nidaamyada korantada. Waxaan had iyo jeer u hoggaansanahay mabaadi'da tayada marka hore iyo mudnaanta macaamiisha, si joogto ah u cusboonaysiinta si loo bixiyo xalal iyo adeegyo wanaagsan. Waxaan rajeyneynaa inaan kula shaqeyno si aan u wada abuurno mustaqbal ifaya!

Hot Tags: Transformers tiirka tamarta, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha