Fahamka Qaabdhismeedka Muhiimka ah ee Transformer
Dec 16, 2025
Fariin ku dhaaftid

Sida aaladda asaasiga ah ee gudbinta korantada iyo isbeddelka korantada ee nidaamyada korantada, waxqabadka transformers wuxuu si toos ah u saameeyaa hawlgalka xasilloon iyo waxtarka gudbinta tamarta ee shabakadaha korantada. Waxqabadka transformer-ka waxaa inta badan lagu go'aamiyaa xulashada agabkiisa ugu muhiimsan iyo qaabdhismeedka qaabdhismeedka.
Laga soo bilaabo beddelka tamarta magnetic ee wareegga magnetic ilaa gudbinta awoodda wareegga, laga bilaabo dammaanadda badbaadada ee nidaamka xakamaynta ilaa taageerada xasilloon ee qaybaha qaabdhismeedka, codsiga shay kasta iyo naqshadaynta qaab-dhismeed kasta waxay qaataan hawlo gaar ah. Maqaalkani waxa uu si nidaamsan u kala saarayaa agabyada asaasiga ah iyo sifooyinka qaab-dhismeed ee unugyada waaweyn ee beddelka, isaga oo ka caawinaya in si buuxda loo fahmo qalabkan muhiimka ah ee awoodda.
I. Agabka Xudunta ah ee Jirka Gudbiyayasha: Xulashada Saxda ah ee ay Hagayso Shaqooyin
Xulashada maadada ee transformers waxay raacdaa mabaadi'da "laqabsiga shaqada, mudnaanta waxqabadka, iyo macquulnimada dhaqaalaha". Alaabta qaybaha kala duwan waxay u baahan yihiin inay buuxiyaan shuruudo badan oo kala duwan sida xajmi magnetic, korantada korantada, xoogga dahaarka, iyo xoogga farsamada. Waxaa ka mid ah, alaabta ugu muhiimsan waxaa loo qaybin karaa afar qaybood: Qalabka wareegga magnetic, qalabka wareegga, qalabka dahaadhka, iyo qalabka dhismaha. Qalab kala duwan ayaa ka wada shaqeeya si loo hubiyo in ay si hufan oo deggan u shaqeeyaan transformers.
(I) Qalabka Wareega Birlabka: Sidayaasha Muhiimka ah ee Beddelka Tamarta Magnetka
Wareegga magnetic waa dariiqa muhiimka ah ee transformers si loo xaqiijiyo kicinta korantada. Shaqadeeda udub-dhexaadka ah waa inay hagto oo ay xoogga saarto goobta magnetic iyo inay yareyso luminta tamarta magnetic. Sidaa darteed, qalabka wareegga birlabku wuxuu u baahan yahay inuu yeesho astaamo ay ka mid yihiin qulqulka magnetic sare, luminta birta oo yar, iyo xasilloonida birta ee wanaagsan. Waqtigan xaadirka ah, qalabka ugu badan ee loo isticmaalo wareegga magnetic in transformers waa go'yaal bir ah oo silikoon ah iyo koojooyin amorphous ah.
Waraaqaha birta ah ee Silicon, oo sidoo kale loo yaqaan xaashida birta korantada, ayaa ah agabka caadiga ah ee wareegyada magnetic transformer. Marka lagu daro silikoon birta saafiga ah, iska caabbinta walxaha si wax ku ool ah ayaa loo wanaajiyay, luminta hadda jirta ayaa la dhimay, iyo qulqulka magnetic si weyn ayaa loo wanaajiyay, taasoo awood u siineysa gudbinta hufan ee tamarta goobta magnetic. Marka loo eego habka duubista, xaashida birta silikoon waxa loo qaybin karaa kulul -oo duuban iyo qabow -nooc duuban. Waxaa ka mid ah, xaashiyaha birta silikoon ee duuban ee qabow waxay leeyihiin sifooyin birlabeed aad u wanaagsan taas oo ay ugu wacan tahay hanuuninta badarka oo aad u nidaamsan, waxaana aad loogu isticmaalaa transformers casriga ah. Waraaqaha birta ah ee Silicon waxaa badanaa lagu farsameeyaa go'yo dhuuban (oo leh dhumucdiisuna tahay 0.35mm ama 0.5mm) waxaana lagu dahaadhay lakabka dahaadhka ee dusha sare si loo sii yareeyo khasaaraha hadda jira ee interlaminar. Marka la isticmaalayo, go'yaal badan ayaa la isku dhejiyaa si ay u sameeyaan xudunta, samaynta wareegga magnetka xiran.


Marka loo eego astaamaha asaasiga ah, waxaa jira farqi muuqda oo u dhexeeya xaashida birta silikoon iyo koofiyadaha amorphous. Isbarbardhigga gaarka ah ayaa ka muuqda dhinacyada soo socda:
|
Isbarbardhigga Cabirka |
Xaashiyaha Birta Silikon |
Amorphous Alloy Cores |
|
Waxqabadka birta luminta |
Marka la barbardhigo sare, darajooyinka caadiga ahi waxay leeyihiin wax ka badan - khasaare rar |
Aad u hooseeya, kaliya 1/3 ilaa 1/5 ee xaashida birta silikoon, tamar aad u fiican -saamaynta badbaadinta malaha |
|
Dhererka Birlabka |
Sare, oo ku habboon meelaha magnetic dhexdhexaadka ah iyo inta jeer ee sarreeya |
Ka sarreeya inta jeer ee hooseeya iyo meelaha birlabeedka daciifka ah, jawaab-celinta magnetic field-ka degdega ah |
|
Habaynta & Guryaha Makaanikada |
ductility wanaagsan, fududahay in la gooyo, feeray iyo raso, la qabsan kara dhismayaasha xudunta u adag |
Jajab sare, fududahay in la jabiyo inta lagu jiro farsamaynta, oo u baahan qalab goyn gaar ah iyo hababka lamination |
|
Qiimaha & Dhaqaalaha |
Farsamada qaan-gaadhka ah, awoodda wax-soo-saarka oo ku filan, deggan oo qiimo jaban |
Habka diyaarinta adag, shuruudaha qalabka sare, qiimaha alaabta xad sare |
|
Xaaladaha Codsiga |
Ku habboon transformers ee dhammaan heerarka korantada, gaar ahaan transformers koronta weyn iyo xaaladaha xasaasi u ah qiimaha iyo kakanaanta habaynta. |
Ku habboon transformers-ka qaybinta, tamarta cusub ee taageerta transformers iyo meelaha kale ee leh shuruudaha hufnaanta tamarta adag |
Koofiyadaha amorphous amorphous waa nooc cusub oo ah walxaha wareegga magnetka ee la sameeyay sanadihii ugu dambeeyay. Waxaa lagu diyaariyaa tignoolajiyada adkaynta degdega ah, iyo habayntooda atomigu waxay soo bandhigaysaa qaab-dhismeedka amorfiska ah ee khalkhalsan. Dabeecaddan ayaa ah sababta ugu muhiimsan ee ay birta u luntay aad uga yar tahay tan xaashida birta silikoon. Marka laga soo tago luminta birta aadka u hooseysa, koofiyadaha amorphous-ka ah ayaa sidoo kale leh faa'iidooyin ay ka mid yihiin awood magnetic sare iyo iska caabin daxalka wanaagsan, taas oo ka dhigaysa inay ku habboon yihiin xaaladaha awoodda leh shuruudaha waxtarka tamarta aadka u sarreeya. Si kastaba ha ahaatee, alaabta daawaha ah ee amorphous sidoo kale waxay leeyihiin dhibaatooyin ay ka mid yihiin jajabnaan sare, habayn adag, iyo kharash aad u sarreeya, kaas oo xaddidaya codsigooda baaxadda leh ee meelaha qaarkood. Iyadoo horumarinta tignoolajiyada processing, awoodda samaynta ee koofiyadaha daawaha amorphous ayaa si tartiib tartiib ah u hagaagtay, iyo saamiga codsiga ay berrinkii of transformers qaybinta si joogto ah u fidin.
(II) Qalabka Wareega: Maamulayaasha Hufan ee Gudbinta Korontada
Wareeggu waa kanaalka loo yaqaan 'Transformers' si loo xaqiijiyo gelinta awoodda, beddelidda iyo soo saarista. Shuruuda aasaasiga ah waa iska caabin hooseeya iyo dhaqdhaqaaqa sare si loo yareeyo khasaaraha korontada inta lagu jiro gudbinta. Alaabta ugu muhiimsan ee korriinka wareegga wareegga waa naxaasta iyo aluminium. Mid kasta oo ka mid ah labada qalabba waxay leedahay faa'iidooyin iyo faa'iido darrooyin u gaar ah, iyo doorasho macquul ah waa in lagu sameeyaa iyada oo loo eegayo arrimo ay ka mid yihiin heerka korantada, muuqaalka codsiga, iyo kharashka kharashka ee transformerka.
Qalabka Copper waxaa si weyn loogu isticmaalaa wareegyada isbeddelka sababtoo ah korantada korantada ee aadka u fiican (labaad kaliya oo lacag ah, oo leh 58 × 10 ⁶ S / m 20 digrii), xoog farsamo oo wanaagsan, iyo iska caabbinta daxalka. Copper waxay leedahay iska caabin hoose. Isla culeyska hadda jira, kirishbooyada naxaasta ayaa leh khasaarooyin yar yar iyo kulayl yar, taas oo si wax ku ool ah u wanaajin karta hufnaanta hawlgalka iyo isku halaynta transformers. Isla mar ahaantaana, naxaasku wuxuu leeyahay ductility wanaagsan waana sahlan tahay in lagu farsameeyo fiilooyinka iyo dabaylaha ee tilmaamo kala duwan, oo la qabsanaya naqshadeynta transformers oo leh qaabab kala duwan. Marka la eego isbarbardhigga dabeecadda, naxaasku wuxuu ka sarreeyaa aluminium marka la eego waxtarka dhaqdhaqaaqa, xasiloonida farsamada, iyo caabbinta gabowga, laakiin yaraanta kheyraadka naxaasta waxay keenaysaa qiimihiisii sare, taas oo si weyn u kordhin doonta qiimaha wax soo saarka qalabka ee transformers weyn ama xaaladaha xasaasiga ah ee kharashka.
Daaraha aluminiumku waxay leeyihiin faa'iidada asaasiga ah ee qiimaha jaban iyo kheyraadka badan. Qiimahoodu waa kaliya 1/3 ka naxaasta ah, taas oo si weyn u dhimi karta qiimaha wax soo saarka ee Transformers. Tani sidoo kale waa sabab muhiim ah oo loogu talagalay codsigooda ku saabsan isbeddellada dhexdhexaadka ah iyo kuwa hooseeya. Inkasta oo conductivity aluminium uu ka hooseeyo kan naxaasta ah (oo leh conductivity of about 37×10⁶ S/m at 20℃, kaliya oo ku saabsan 64% ka mid ah naxaasta), deficiency ee conductivity lagu magdhow karaa by kordhinta iskutallaabta - qaybta qaybta ee kaari (sida caadiga ah 1.6 jeer in kaari naxaas ah), buuxinta shuruudaha gudbinta wareegga. Si kastaba ha ahaatee, kondhomiyeyaasha aluminiumku waxay leeyihiin cillado muuqda: xoog farsamo oo hooseeya, kaliya kala badh xoogga cufan ee naxaasta; Dusha sare waxay u nugul tahay oksaydheynta si ay u sameyso filim sare oo oksaydh ah, oo saameeya xasilloonida hadhaaga; iyo daxalka korantada ayaa u nugul inuu dhaco marka lagu xiro biraha kale sida naxaasta, taasoo keenta xiriir xumo. Sidaa darteed, habab gaar ah waa in la qaataa inta lagu jiro habaynta iyo rakibidda, sida isticmaalka naxaasta{14}}kala-goysyada kala-guurka aluminiumka iyo samaynta daawaynta lidka ku ah qaybaha xidhiidhka. Sannadihii u dambeeyay, iyada oo la horumarinayo tignoolajiyada agabka aluminiumka aluminiumka, sare{17}kaariyeyaasha aluminiumka aluminiumka ah ee lagu sameeyay iyadoo lagu daray magnesium, silicon iyo walxo kale oo aluminium ah ayaa si weyn u wanaajiyay xooggooda makaanikada iyo iska caabinta daxalka, iyaga oo ka gudbay ciladaha daariyaasha aluminiumka saafiga ah ilaa xad, iyo kala duwanaanshaha codsigooda ayaa si tartiib tartiib ah u sii fidaya.


Isbarbardhigga waxqabadka faahfaahsan ee u dhexeeya kooriyeyaasha naxaasta iyo aluminiumka ayaa lagu muujiyay shaxdan soo socota:
|
Tilmaamaha Waxqabadka |
Sameeyayaasha Copper |
Aluminium Conductors |
|
Dhaqdhaqaaqa Korontada (20 darajo) |
Sare (58×10⁶ S/m), IACS 100% |
Dhexdhexaad (37×10⁶ S/m), IACS ~ 64% |
|
Iska caabin (20 darajo) |
Hooseeyo (1.68×10⁻ Ω·m) |
Sare (2.82×10⁻⁸ Ω·m) |
|
Xoogga Makaanikada |
Xoog adag oo sarreeya, iska caabin daal wanaagsan |
Hooseeyo, fududahay in la qalloociya marka lagu jiro diiqada |
|
Iska caabinta daxalka |
Wanaagsan, ma fududa in oxidize |
Liidata, filimka oksaydhka dusha sare wuxuu saameeyaa waxqabadka |
|
Habaynta & Rakibaadda |
ductility wanaagsan, fududahay in la farsameeyo oo la isku xidho |
Waxay u baahan tahay habab gaar ah (tusaale, kala-goysyada kala-guurka) |
|
Qiimaha |
Sare, kheyraad yar |
Hoose, kheyraad badan |
|
Xaaladaha Codsiga |
Transformers sare{0}awood sare,-Shuruudaha hufnaanta sare |
Transformers dhexdhexaad iyo hooseeya, kharash{0}mashruuc xasaasi ah |
(III) Qalabka Dahaarka: Caqabadaha Muhiimka ah ee Hawlgalka Badbaadada ah
Inta lagu jiro hawlgalka transformers, waxaa jira kala duwanaansho sare oo suurtagal ah oo u dhexeeya wareegga iyo wareegga magnetka, iyo inta u dhaxaysa wareegga iyo qaybaha dhismaha. Shaqada qalabka dahaadhida waa in la go'doomiyo kala duwanaanshahan iman kara, ka hortagga khaladaadka sida qulqulka iyo wareegyada gaaban, iyo hubinta badbaadada iyo hawlgalka qalabka. Alaabta dahaadhku waxay u baahan yihiin inay lahaadaan wax qabad dahaar aad u wanaagsan, iska caabin heerkul sare ah, caabbinta gabowga, iyo xoogga farsamada. Marka loo eego qaybaha codsiga iyo shaqooyinka, waxaa loo qaybin karaa saddex qaybood: qalab adag oo adag, walxaha dareeraha ah, iyo walxaha gaaska.
Walxaha dahaadhka adagwaa udub dhexaadka nidaamka daahitaanka transformer-ka, oo lagu garto qaab xasilan iyo{0}}waxqabad dahaareed oo waara. Inta badan waxaa ka mid ah waraaqaha dahaadhka ah, kartoonada dahaarka, varnish dahaarka, guddiga maro epoxy galaas, spacers, giraanta xagal, iwm. Insulating waraaqaha iyo kartoonada insulating yihiin waxyaabaha aasaasiga ah ee adag insulating, kaas oo loo qaybin karaa fiber dhirta (sida saxarka alwaax) iyo fiber synthetic (sida fiber aramid) sida alaabta ceeriin. Waraaqaha dahaadhka fiber-ka ee dhirta ayaa leh qiimo jaban iyo waxqabadka nuugista saliidda oo wanaagsan, waxayna samayn kartaa nidaam is-dhexgal ah oo leh saliid dahaar ah. Inta badan waxa loo istcimaalaa dhexda- leexashada iyo dhexda{6}}lakabka dabaysha iyo go'doominta udhaxeeya dabaylaha iyo dabaylaha; Waraaqaha dahaadhka fiber synthetic (sida warqadda Nomex) waxay leedahay faa'iidooyinka iska caabbinta heerkulka sare ({7}}kulka shaqaynta muddada dheer ilaa 180 digrii), caabbinta gabowga, iyo xoogga farsamada sare, waxayna ku habboon tahay qaybaha muhiimka ah ee dahaarka ee qalalan Daaqadaha dahaadhka ah waxa loo qaybiyaa saliid{13}}dharka dahaadhka ah ee ku salaysan resin insulating varnish. Saliida -Valshka ku salaysan waxa ay leedahay qiimo jaban laakiin iska caabin heerkulkeedu liito, waxaana inta badan loo isticmaalaa transformers yar iyo hoose{16}; varnish resin (sida epoxy resin varnish, polyurethane varnish) waxay leedahay iska caabin heerkul sare ah iyo xoogga dahaarka. Iyada oo la jeexjeexayo dabaylaha, waxay buuxin kartaa meelaha bannaan ee dabaysha waxayna duubi kartaa fiilooyinka si ay u sameeyaan lakabka daboolka joogtada ah, taas oo aan hagaajinaynin oo kaliya waxqabadka daboolka laakiin sidoo kale waxay kordhisaa daacadnimada dabaysha waxayna ka hortagtaa gariirka iyo xirashada. Looxa maro dhalada ah ee Epoxy wuxuu ka samaysan yahay maro dhalada ah oo lagu shubay resin epoxy iyo kulayl{19} la riixay, kaas oo leh xoog sare, iska caabin heerkul sare ah, iyo sifooyin dahaadh aad u fiican. Inta badan waxaa loo isticmaalaa in lagu sameeyo qaybaha dahaarka qaab dhismeedka sida taageerooyinka, qaybo ka mid ah, iyo terminal blocks of transformers; Spacers iyo giraangiraha xagasha ayaa inta badan laga sameeyaa kartoonada ama walxaha epoxy, kuwaas oo loo isticmaalo taageerada gudaha ee dabaylaha iyo dahaarka dabaylaha dabaylaha siday u kala horreeyaan, hubinta qaab dhismeedka xasilloon ee dabaysha iyo fogaanta dahaarka ku filan.
Walxaha dahaadhka dareeraha ah, oo sidoo kale loo yaqaan saliidda daboolaya, waxaa inta badan lagu isticmaalaa saliidda{0}}Transformers immersed waxayna leeyihiin saddex hawlood oo asaasi ah: dahaarka, qaboojinta, iyo dabar goynta. Waxay si wax ku ool ah u wanaajin karaan awoodda iyo nolosha adeegga transformers. Saliidaha dahaadhka ah ee sida caadiga ah loo isticmaalo waxa loo qaybiyaa saddex qaybood: Saliida dahaadhka macdanta, Saliida dahaadhka ah ee synthetic, iyo saliidda khudaarta. Saliida dahaadhka macdanta ayaa laga sifeeyaa batroolka, iyadoo leh faa'iidooyin ay ka mid yihiin waxqabadka dahaarka aad u fiican (burburka tamarta ilaa 40kV ama ka badan), hufnaanta kulaylka sareeyo, dareere wanaagsan, iyo qiimo jaban. Waxay la jaanqaadi kartaa maaddooyinka adag ee adag waxayna si buuxda u daadin kartaa warqadda dahaadhka si ay u sameeyaan nidaam isku-dhafan. Hadda waa sheyga dahaadhka dareeraha ah ee loogu isticmaalka badan yahay ee saliidda{7}}Transformers immersed ee adduunka oo dhan. Saliida dahaadhka ah ee synthetic waa saliid dahaadh ah oo lagu diyaariyo hababka isku dhafka kiimikada, sida polyalphaolefin iyo saliid silikoon. Sifadeeda ugu weyni waa barta iftiimaysa (badanaa ka sarraysa 300 digrii), iska caabin gabow xoog leh, iyo heerkul hooseeya{11}} Waxaa si weyn loogu isticmaalaa xaaladaha leh shuruudaha ilaalinta dabka oo sarreeya (sida - dhismayaal sare, saldhigyo dhulka hoostiisa ah), laakiin qiimaheeda sare waxa uu xaddidaa caannimadeeda weyn{14}}. Saliida dahaadhida khudaarta waa saliid dahamiya deegaanka u wanaagsan oo laga sifeeyay saliidaha khudradda sida saliidda soybean iyo saliidda kufsiga. Waxay leedahay faa'iidooyinka biodegradability wanaagsan, dhibic sare, iyo khayraadka la cusboonaysiin karo, kaas oo la jaan qaadaya horumarka horumarinta deegaanka cagaaran. Si kastaba ha ahaatee, iska caabinteeda gabowga iyo heerkulka hoose{18}} dareeraha heerkulka ayaa weli u baahan in la hagaajiyo, oo hadda inta badan waa duuliye{19}}oo lagu codsado qalab yar sida transformers qaybinta.
Walxaha daboola gaastawaxay leeyihiin sifooyin saameyn yar oo deegaanka ah, kulaylka isku midka ah ee daadinta, iyo wax khatar ah oo daadanaya ma jirto. Waxa inta badan loo isticmaalaa dahaarka kaaliyaha ee gaaska{1}}Transformers dahaaran (GIT) iyo qalalan{2}}nooca transformers. Gaasaska sida caadiga ah loo isticmaalo waxaa ka mid ah sulfur hexafluoride (SF₆), nitrogen (N₂), iyo hawo qalalan. Sulfur hexafluoride waa mid ka mid ah walxaha gaaska dahaarka leh ee leh waxqabadka dahaarka ugu fiican hadda. Xooggeeda goob burburkeedu waa in ka badan saddex jeer ta hawada, waxayna leedahay qaanso aad u wanaagsan{6}daminta, sifooyinka kiimikaad ee deggan, mana fududa da'da. Sidaa darteed, waxa si weyn loogu isticmaalaa gaasta{8}Transformers dahaaran iyo gaasta{9}}dalalka dahaaran Si kastaba ha ahaatee, sulfur hexafluoride waa gaas aqalka dhirta lagu koriyo oo xoog leh lehna awood kulayl caalami ah oo aad u sareysa (GWP) iyo waqti dheer oo ku haynta jawiga. Iyadoo la raacayo xeerarka ilaalinta deegaanka ee sii kordheysa ee adag, codsigeedu wuxuu ku xiran yahay xannibaadyo aad iyo aad u badan. Waqtigan xaadirka ah, tignoolajiyada dib-u-warshadaynta ayaa inta badan loo isticmaalaa si loo yareeyo qiiqa qiiqa. Nitrojiin, sida gaas aan shaqaynayn, waxay leedahay faa'iidooyinka il ballaadhan, qiimo jaban, ilaalinta deegaanka, iyo wasakh la'aan. Inkasta oo wax qabadkeeda dahaarka uu ka hooseeyo kan sulfur hexafluoride, waxay buuxin kartaa shuruudaha dahaarka ee Transformers iyadoo kordhinaysa cadaadiska gaaska (badanaa 0.3-0.5MPa). Badanaa waxa loo isticmaalaa nayroojiin{18}}ilaalinta buuxda ee qalalan{19}}nooca transformers iyo gaasta kale ee gaaska{22}}Transformers dahaaran. Hawada qallalan waa hawo la demiyo, oo leh waxqabadka dahaarka oo la mid ah nitrogen iyo kharash yar. Inta badan waxaa loo isticmaalaa dahaarka iyo qaboojinta transformers-yada yar yar ee qallalan, laakiin wax qabadkeeda dahaarka waxaa si weyn u saameeya qoyaanka, markaa waxa ku jira biyaha waa in si adag loo xakameeyo.

cajalad dhejis ah

Warqad qallafsan

DMD

Silig warqad ah oo dahaaran

Filimka polyester-ka

Maro Prepreg ah

Epoxy resin kab gariiradda

Silig la dahaadhay

FR3 saliid
Isbarbardhigga sifooyinka muhiimka ah ee agabka dahaadhka ee kala duwan ayaa lagu muujiyay shaxda soo socota:
|
Nooca dahaarka |
Qalabka Gaarka ah |
Astaamaha Muhiimka ah |
Xaaladaha Codsiga |
|
Dahaarka adag |
Waraaqaha dahaadhka ah (dhirta/ fiber-synthetic), varnish dahamiya, looxa maro dhalada epoxy |
Qaab xasiloon,{0}dahaar dheer oo waara, heerkul kala duwan oo iska caabin ah |
Dahaarka dabaysha, qaybaha dahaarka dhismaha |
|
Dahaarka dareeraha ah |
Saliida dahaarka macdanta, Saliida dahaadhka synthetic, Saliida dahaarka khudradda |
Dahaarka + qaboojinta + baabi'inta arc, dareere wanaagsan |
Saliida -Transformers-ka la quusiyay, -qalabka awooda sare leh |
|
Xakamaynta gaaska |
Sulfur hexafluoride (SF₆), nitrogen (N₂), hawo qalalan |
Ma jirto khatar daadin, kulayl caadi ah oo daadanaya |
Gaaska -Transformers-ka dahaaran, qalalan{1}}nooca Transformers |
(IV) Qalabka Dhismaha iyo Agabka: Dammaanadaha Muhiimka ah ee Taageerada iyo Ilaalinta
Qalabka qaab-dhismeedku iyo qalabyada waa qaybo muhiim ah oo ka mid ah beddelayaasha kuwaas oo garwaaqsada taageerada farsamada, xoojinta qaabdhismeedka, la socodka waxqabadka, iyo ilaalinta badbaadada. Nakhshaddooda iyo xulashada alaabtu waxay si toos ah u saameeyaan xasilloonida farsamada, isku halaynta shaqada, iyo nolosha adeegga beddelayaasha.
Qalabka qaab-dhismeedku waxay inta badan qabtaan hawlaha taageerada beddelka, xoojinta wareegga magnetic iyo wareegga, iyo daboolida dareeraha. Qaybaha muhiimka ah waxaa ka mid ah xajinta, taangiyada saliidda, radiators, ilaalinta saliidda, iwm haanta saliiddu waa qaybta udub dhexaadka u ah saliidda -Transformers immersed, welded with steel plates, loo isticmaalo in lagu meeleeyo saliid dahaadhka iyo qaab dhismeedka ugu muhiimsan ee transformerka, isla markaana waxay ciyaartaa doorarka xidhidhiyaha, ka hortagga daxalka, iyo ilaalinta farsamada; radiators ayaa loo qaybiyaa noocyo kala duwan sida noocyada finned iyo tuubooyinka, kuwaas oo u gudbiya kulaylka ka yimaada transformerka inta lagu jiro hawlgalka hawada iyaga oo kordhinaya aagga kulaylka si loo gaaro qaboojinta qalabka; kaydiyaha saliida wuxuu ku xiran yahay dusha sare ee haanta saliida, waxaa loo isticmaalaa in lagu magdhabo balaadhinta mugga iyo hoos u dhigista saliida dahaadhka sababtoo ah isbeddelka heerkulka, isla markaana hoos u dhigista aagga xidhiidhka u dhexeeya saliidda dahaadhka iyo hawada si dib loogu dhigo gabowga saliidda.

Taangiga

raadiyaha

ilaalinta saliidda
Qalabka wax-ka-beddelka ahi way kala duwan yihiin iyadoo loo eegayo nooca beddelka (qalalan{0}nooca ama saliidda{1}}lagu dhex shubay) oo inta badan waxay qabtaan hawlo kormeer iyo ilaalin waxqabad. Qalabka muhiimka ah ee noocyada qalalan-nooca transformers waxaa ka mid ah kontaroolayaasha heerkulka, marawaxadaha, qalabka wax ka beddelka, iwm. marawaxadu waxa ay ku xidhan tahay heerkulka heerkulka oo si toos ah u bilaabma marka heerkulku kordho si kor loogu qaado saamaynta kulaylka; Transformer-ka aaladda waxaa loo isticmaalaa in lagu cabbiro tamarta iyo hadda ee beddelka iyo bixinta taageerada xogta cabbirka iyo ilaalinta nidaamka awoodda. Marka lagu daro heerkulbeegiyaha, agabka saliida-Transformers immersion waxa kale oo ka mid ah gaaska relays, valves-ka cadaadiska cadaadiska, beddelayaasha tuubada, iwm. Marka cilad ka dhacdo gudaha transformerka si ay u dhaliso gaas ama heerka qulqulka saliida dahaadhka ah uu yahay mid aan caadi ahayn, waxay soo saartaa digniinta wakhtigeeda ama waxay gooyaa sahayda korontada; tuubada cadaadiska cadaadiska waxaa loo isticmaalaa in si toos ah loo sii daayo cadaadiska marka cadaadiska gudaha taangiga saliidda uu kor u kaco qiimo gaar ah sababtoo ah cillad si looga hortago in haanta saliidda ay dillaacdo; beddelka tuubada waxaa loo isticmaalaa in lagu hagaajiyo tirada dabaylaha leexdo ee Transformer si ay u ogaadaan hagaajinta danab wax soo saarka si ay ula qabsadaan isbedbedelka danab korantada.

tilmaame heerkulka saliidda oo leh xiriir

taageerayaasha qaboojinta

CT

BUCHHOLZ gudbinta

qalabka cadaadiska

OLTC
II. Astaamaha Isku-dhafka ah ee Qaab-dhismeedka Jirka Weyn ee Beddelka
Qaab dhismeedka ugu muhiimsan ee wax beddelka waa isku dhafka dabiiciga ah ee walxo kala duwan, samaynta nidaam isku-dhafan oo isku-dhafan "circuit magnetic - circuit - insulation - qaab dhismeedka". Xudunta, sida xudunta wareegga magnetka, waxay ku qotontaa haanta saliidda (saliid -Transformer immersed) ama bracket (qalalan{5}}nooca transformer) iyada oo loo marayo isku dhejisyo. Dabayshu waxay ku dhaawacan tahay tiirarka xudunta u ah, samaynta unugga udub dhexaadka u ah induction electromagnetic; Walxaha adag ee dahaadhida waxaa loo isticmaalaa in lagu go'doomiyo dabaylaha iyo xudunta u dhaxaysa, iyo inta u dhaxaysa dabaylaha iyo dabaylaha. Saliidda -Transformers-ka la quusiyay, saliidda dahaadhka waxay buuxisaa farqiga u dhexeeya qaybaha kala duwan si loo gaaro dahaarka iyo qaboojinta isku mar; Qaybaha qaab dhismeedka sida taangiyada saliidda iyo xirmooyinka waxay bixiyaan taageero makaanik ah qaybaha xudunta u ah, iyo agabka dhabta ah -waqtiga la soco heerka hawlgalka qalabka oo bilow habka ilaalinta haddi cilado
Naqshadaynta qaabdhismeedku kaliya maaha inay hubiso xaqiijinta hufan ee soo-saarka elektromagnetic-ka laakiin sidoo kale waxay hubisaa badbaadada hawlgalka iyada oo loo marayo nidaamka dahaarka iyo agabka ilaalinta. Isla mar ahaantaana, iyada oo la kaashanayo qalabka dhismaha iyo doorka qaybaha kuleylka kuleylka, nolosha adeegga qalabka ayaa la kordhiyaa. Xaalado kala duwan oo codsi ah, qaab dhismeedka beddelka ayaa loo hagaajin doonaa si bartilmaameed ah. Tusaale ahaan, nooca qalalan - nooca transformers waxay baabi'iyaan haanta saliidda iyo saliidda dahaadhka, waxay qaataan qaboojinta hawada iyo dahaarka adag, waxayna ku habboon yihiin gudaha dhismayaasha leh shuruudaha ilaalinta dabka; saliid -Transformers immersed, oo leh wax qabadkooda kulaylka aadka u fiican, waxay ku haboon yihiin bannaanka - muuqaalada gudbinta awooda baaxada leh.
III. Gabagabo
Xulashada agabka iyo qaab-dhismeedka qaab dhismeedka transformer-ka guud ayaa ah aasaaska xaqiijinta hawlaha asaasiga ah. Dareemidda magnetic sare ee qalabka wareegga magnetic, iska caabin hooseeya ee qalabka wareegga, go'doominta adag ee alaabta dahaadhka, iyo doorarka taageerada iyo ilaalinta ee qalabka dhismaha iyo qalabyada si wadajir ah u dhisa qalab wax ku ool ah, badbaado leh, oo lagu kalsoonaan karo. Horumarka joogtada ah ee shuruudaha nidaamyada korantada ee hufnaanta tamarta iyo isku halaynta, agabka beddelka ayaa sidoo kale ku horumaraya tamar badan{2}}badbaadinta iyo jihada waarta. Tusaale ahaan, adeegsiga xargaha daawaha amorfiska ah iyo walxaha cusub ee dahaarka isku dhafan ayaa si tartiib tartiib ah loo faafiyaa. Naqshadaynta qaabdhismeedku waxay noqonaysaa mid caqli badan. Marka la isku daro tignoolajiyada dareema iyo teknooloojiyada Internetka Waxyaabaha, la socodka saxda ah iyo hawlgalka caqliga leh iyo dayactirka heerka hawlgalka transformer ayaa la xaqiiqsaday. - Faham qoto dheer oo ku saabsan agabka iyo qaab dhismeedka transformer-ka jirka guud ayaa muhiimad weyn oo hagaya u leh nakhshadeynta, samaynta, hawlgalka iyo dayactirka, iyo cusboonaysiinta qalabka, waxa kale oo ay siisaa dammaanad adag oo lagu hubinayo habsami u socodka nidaamka awooda.
Maqaalka oo ah nooca Ingiriisida waxa aan ku dhammaystiray saddex jaantus oo is barbar dhig ah. Ma waxaad u baahan tahay inaan hagaajiyo qaabka (sida farta, kala dheeraynta cutubka) si aan aad ugula jaanqaado qeexida dukumeentiyada Word, ama aan wax ka beddelo nuxurka qayb gaar ah? Waxaan sidoo kale kaa caawin karaa inaad u dhoofiso waxa ku jira sidii qoraal qoraal ah oo dukumeenti Word ah si toos ah loogu isticmaalo.