2500 kVA pad mounted distribution transformers

Tamarta -badbaadinta iyo hufnaanta, ilaalinta saacad kasta – Saddex{1}}Safafka wejiga{2}}Ku rakiban Transformer wuxuu xaqiijiyaa walwalka{3}} Korontada bilaashka ah!

 

01 Guud

1.1 Asalkii Mashruuca

SCOTECH waxay soo saartay 2 unug oo ka mid ah 2500 kVA pad ku rakiban transformer-ka Kanada 2024. Awoodda lagu qiimeeyay beddelka waa 1000 kVA qaboojinta KNAN, oo leh danab hoose 25GrdY/14.4 kV ilaa danab sare 0.6y/0.347 kV. waxay samaysteen koox fallaago ah YNyn0. Transformer-kan suufka lagu rakibay ee ay soo saartay shirkadeena waxaa loo isticmaali karaa shabakadda giraanta iyo habka korontada ee terminaalka, beddelaadkuna waa dabacsan yahay oo habboon. Xidhiidhiyaha fiilada nooca suxulka waxa lagu xidhi karaa oo la gelin karaa in ka badan 15 jeer 200A load current, waxaana loo isticmaalaa sidii culayska wareejinta xaaladaha degdega ah, waxana uu leeyahay sifada go'doominta.

Waxaan hubineynaa in mid kasta oo ka mid ah cutubyada nala keenay uu maray imtixaan adag oo aqbalaad ah. Waxaan bixinaa hal{1} adeeg xirmo laga bilaabo la talinta, xigashada, soo saarista, rakibida, hawlgelinta, tababarka ilaa adeegyada iibka kadib, alaabadayadu hadda waxay ka shaqeeyaan in ka badan 50 degmo oo aduunka ah. Waxaan hiigsaneynaa inaan noqono alaab-qeybiyahaaga ugu kalsoonida badan iyo sidoo kale lamaanahaaga ugu fiican ganacsiga!

 

1.2 Tilmaamaha Farsamada

1000 kVA suuf ku rakiban tafatirka tafatirka iyo xaashida xogta

loo geeyey
Kanada
Sannadka
2024
Nooca
suuf ku rakiban transformer
Heerka
CSA C227.4:21
Awood lagu qiimeeyay
2500kVA
Soo noqnoqoshada
60HZ
Marxaladda
3
Nooca qaboojinta
KNAN
Korantada aasaasiga ah
25GrdY/14.4 kV
Voltage Secondary
0.6y/0.347 kV
Qalabka dabaysha
Aluminium
barokaca xagal
YNyn0
Caqabada
5.75%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
2.5KW
Load Lumista
24KW
Agabka
Habaynta caadiga ah

 

1.3 Sawirro

2500 kVA suuf ku rakiban jaantuska beddelka sawirka iyo cabbirka.

2500 kVA pad mounted distribution transformers diagram 2500 kVA pad mounted distribution transformers nameplate

 

 

02 Wax-soo-saarka

2.1 Core

Habka wax-soo-saarka xudunta u ah transformer-ka waxaa inta badan ka mid ah tallaabooyinka soo socda:

1. Diyaarinta walxaha: Dooro -qabow tayo sare leh{2}} xaashida birta silikoon duuban oo u jar cabbirka ku habboon sida waafaqsan shuruudaha naqshadaynta.

2. Isku dhejinta: Ka dib markii lagu dahaadhay xaashida birta silikoon leh rinjiga dahaaran ee filimka, ku dheji xaashida birta silikoon mid mid si waafaqsan nooca E, nooca C ama qaab dhismeedka giraanta si aad u sameysid tiirka xudunta u ah iyo harqoodka birta.

3. Bar alxanka ama xidhidhiyaha: xaashida birta silikoon waxa lagu wada hagaajiyaa alxanka barta ama birta aan -isku xidhin si midba midka kale uga ilaaliyo dhaqaaqa sababtoo ah awooda korantada inta lagu jiro hawlgalka.

4. Iyada oo loo marayo xudunta ama goynta dabaysha: marka loo eego naqshadaynta beddelka, dabaysha iyada oo loo marayo tiirka xudunta u ah ama ku dheji xudunta.

5. Baadhitaanka iyo daawaynta: Hubi fiditaanka, nadiifinta iyo heerka dahaarka xudunta birta, oo sax oo kaabi daaweynta dahaarka haddii loo baahdo.

6. Isku-dhafka iyo baakadaha: Iskudubarid xudunta birta, dabaysha, xajinta iyo qaybaha kale si ay u noqdaan qalab isku dhafan oo dhamaystiran, iyo habaynta baakadaha si loo hubiyo in korantada wanaagsan iyo xasiloonida farsamada.

transformer core production process

 

2.2 Dabaylaha

2500 kVA pad mounted distribution transformers winding

Dabaylaha foil danab yar

Qaybinta hadda jirta ee axial ayaa si xor ah u habaysa

Waxay yaraynaysaa xoogaga xiiraya

Dabaysha ka dib, Prepreg wuxuu ku dul dheggan yahay xaashida kirishbooyada si uu u sameeyo tuubo cufan iyadoo la raacayo habka dabci.

Dabaysha danab sare

Mashiinada dabaysha oo dhami iyo badh - oo toos ah

Dhaldhalaalka{0}} silig dahaaran oo leh dabaylo joogto ah oo jiid jiid dhululubo sidaha, ama si toos ah dabaysha LV

Dahaarka lakabka ee waraaqda fiilada tayada sare leh {{0}

Dabool faashad ka samaysan bireed soo yaraanaya oo loogu talagalay dabaysha is haysta oo leh jawaab gaaban oo gaaban iyo qaybinta tamarta ugu fican

 

2.3 Haanta

Taangiga beddelka waa in lagu dhufto saxan bir ah oo xooggan. Tallaabooyinka gaashaanka birlabeedka waa in lagu qaadaa gudaha haanta shidaalka si loo yareeyo khasaaraha leexsan. Qalabaynta iyo dahaarka gaashaanka magnetic waa in ay ahaataa mid wanaagsan si looga fogaado kulaylka ama dheecaanka sababtoo ah xiriir xumo. Dhammaan noocyada gaashaammaadka korantada waa inay ahaadaan kuwo shaqaynaya oo dhulka si la isku halleyn karo si looga fogaado dareeraha hakadka ah ama saameyn ku yeelanaya lumitaanka koronto ee dabaysha. Taangiga shidaalku waa inuu lahaadaa xoog la isku halayn karo oo awood u leh inuu u adkaysto tijaabada xoogga farsamada oo leh faakuum 133Pa iyo cadaadis togan oo 98kPa ah. Haanta shidaalka waa in aan la dhaawacmin ama aan si joogto ah u habayn si ay ula kulanto cadaadiska taban ee cirbadeynta vacuum oil duritaanka iyo cadaadiska togan ee shaqada. Haanta saliidda waa in si adag loo xiraa si loo buuxiyo shuruudaha wax daadin ah ka dib duritaanka saliidda beddelka. Haanta saliiddu waa inay lahaataa qaab sax ah iyo saxnaanta booska si ay u buuxiso shuruudaha tayada ee isku-dhafka beddelka. Awoodda haanta saliidda ayaa go'aamisa cidhiidhiga iyo rakibidda saxnaanta haanta saliidda. Marka xoogga taangiga saliidda kuma filna in ay keento qallafsanaan, flanges, dhuumaha, qaybaha meelaynta, iwm waxay keeni doontaa qallafsanaan, iyo cidhiidhi iyo saxnaanta rakibaadda ayaa saameyn doona.

high strength steel plate oil tank

 

2.4 Kulanka ugu dambeeya

2500 kVA pad mounted distribution transformers assembly

Habka isu-ururinta transformer-ku wuxuu daboolayaa heerka diyaarinta si loo hubiyo in agabka iyo qalabka loo baahan yahay la heli karo; Samee kor u qaadista transformer-ka, si sax ah u hagaaji dhinacyada tamarta sare iyo kuwa hooseeya; rakibo qalabyada, sida daboolka, barkin saliid, iwm.; Samee hawlaha bamgareynta faakuumka iyo buuxinta saliidda.

 

 

03 Tijaabinta

1. Isku-xidhka oo dhan iyo meelaha taabo

2. Barokaca xaglaha ah

3. Maya - khasaare 100% la qiimeeyay

4. Hadda xiisaha leh ee 100% danab lagu qiimeeyay

5. Culayska lumitaanka iyo cidhiidhiga wakhtiga la qiimeeyay

6. danab la dabaqay

7. danab la kiciyay

8. daadinta taangiga Transformer{1}}baaritaanka ogaanshaha

9. Imtixaan joogto ah

 

2500 kVA pad mounted distribution transformers test
2500 kVA pad mounted distribution transformers fat

 

 

04 Baakaynta iyo dhoofinta

2500 kVA pad mounted distribution transformers  tin foil bag packing
2500 kVA pad mounted distribution transformers shipping

 

 

05 Goobta iyo Kooban

Waad ku mahadsan tahay xiisahaaga saddexdayada{{0}wajiga{1}} Iyada oo waxqabadkeeda hufan oo xasilloon, badbaadada aadka u wanaagsan, iyo cimri dhererka, alaabtan ayaa si weyn loogu isticmaalaa warshadaha, ganacsiga, iyo nidaamyada awood qaybinta dadweynaha, siinta koronto la isku halleyn karo iyo xalalka tamarta la hagaajiyay ee macaamiisheena. Waxaa naga go'an inaan keenno{3}}alaabooyin tayo sare leh iyo adeegyo xirfadeed. Waxaan rajeyneynaa inaan kula shaqeyno si aan u abuurno mustaqbal waara warshadaha tamarta! Wixii macluumaad dheeraad ah, fadlan xor u noqo inaad nala soo xidhiidho wakhti kasta!

2500 kVA 3 phase pad mounted distribution transformers

 