2500 kVA Transformers Pad-12.47 / 0.48 kV|USA 2025

2500 kVA Transformers Pad-12.47 / 0.48 kV|USA 2025

Dalka la geynayo: Ameerika 2025
Awoodda: 2500 kVA
Voltage: 12.47 / 0.48 kV
Feature: oo leh IFD
U dir sooji

 

 

2500 kVA three phase pad mounted transformer

Badbaadada iyo la isku halayn karo, sahay koronto caqli leh, saddex{0}}Transsameeyaha weji wuxuu ilaaliyaa baahidaada koronto!

 

 

01 Guud

1.1 Dulmar - Awooda Cagaaran, Qaybinta Wacan

Saddexda 2500 kVA{1} suufka wejiga - ee lagu rakibay transformer-ka la keenay suuqa Maraykanka waxa lagu dhisay iyadoo maskaxda lagu hayo xeerarka hufnaanta DOE waxaana loo qaabeeyay - waaritaanka deegaanka muddada dheer, iyadoo la adeegsanayo haanta birta ah, nidaamka ilaalinta caqliga, iyo qaab dhismeedka hoose - qaab dhismeedka khasaaraha kaas oo si dabiici ah u yareeya qashinka tamarta. Hoos u dhigista khasaaraha, kala bixinta nolosha adeegga, iyo ilaalinta baahiyaha dayactirka, koronto-bixiyehu waxa uu keenaa awood ka sii nadiifsan oo ka sii nadiifsan, isaga oo si aamusan u yareynaya raadkiisa isagoo taageeraya shabakad qaybin waarta.

 

 

1.2 Tilmaamaha Farsamada

2500 kVA suuf ku rakiban nooca tafatirka tafatirka iyo xaashida xogta

loo geeyey
Ameerika
Sannadka
2025
Nooca
suuf ku rakiban transformer
Heerka
Ameerika
Awood lagu qiimeeyay
2500 kVA
Soo noqnoqoshada
60HZ
Marxaladda
3
Quudinta
Loop
Hore
dhintay
Nooca qaboojinta
ONAN
Korantada aasaasiga ah
12.47GrdY/7.2 kV
Voltage Secondary
0.48Y/0.277 kV
Qalabka dabaysha
Aluminium
Qalabka Haamaha
Birta Aan Lahayn
Qalabka Qaybta
Birta Aan Lahayn
barokaca xagal
YNyn0
Caqabada
5.75%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
2.4 kW
Load Lumista
15.79 kW
Agabka
Habaynta caadiga ah

 

 

1.3 Sawirro

2500 kVA suuf ku rakiban jaantuska beddelka sawirka iyo cabbirka.

2500 kVA three phase pad mounted transformer diagram 2500 kVA three phase pad mounted transformer nameplate

 

1.4 Faa'iidooyinka Waxtarka Tamarta

 

FIVE-COLUMN CORE

 

DOE-U hoggaansami hooseeya-Naqshad lumis

 

Transformer-ku waxa uu la kulmaa shuruudaha hufnaanta DOE, taas oo macnaheedu yahay - lumintiisa 2.4 kW iyo luminta 15.79 kW si joogto ah ayuu u hooseeyaa. Inkasta oo tirooyinkani ay u muuqdaan kuwo yar oo go'doon ah, waxay ku ururaan - kaydka tamarta muddada dheer taas oo si joogto ah u dhimaysa kharashyada hawlgalka iyo culayska deegaanka sannadaha shaqada joogtada ah.

 

Wareegga Magnetic ee La Habeeyay - Shan{1}}Column Core

 

Xudunta tiirka ee shanta- waxa ay abuurtaa dariiq birlabeed fudud, hoos u dhigaya cufnaanta qulqulka, cabudhinta iswaafajinta, iyo yaraynta xadhkaha dambe ee transformers sida caadiga ah soo saaraan. Waxa kale oo ay si dabiici ah u dhimaysaa khasaaraha falcelinta, taas oo u oggolaanaysa nidaamka oo dhan inuu si hufan u shaqeeyo iyo xasilloonida xasilloon oo dareemaya ula kac halkii shil.

 

ONAN Qaboojinta Dabiiciga ah

 

Nidaamkeeda qaboojinta ee ONAN waxay si buuxda ugu xidhan tahay dhaqdhaqaaqa hawada dabiiciga ah {{0} ma jiro taageere, matoor la'aan, ma jiraan wax awood sawireed oo dheeri ah{1}} markaa transformerku wuxuu isku qaboojiyaa si fudud oo aan dadaal lahayn, iyadoo adeegsanaysa socodka hawo-mareenka si uu u habeeyo heerkulka iyada oo laga fogaanayo isticmaalka tamarta kaaliyaha ah, yaraynta buuqa, iyo hoos u dhigista muddada dheer{2}} baahiyaha dayactirka.

 

02 Wax-soo-saarka

2.1 Core

Ka faa'iidaysiga saddexda{0}wajiga shanaad- xudunta tiirka waxay hubisaa qaybinta qulqulka magnetic isku midka ah ee weji kasta, gaarista isku xidhka birlabeedka wanaagsan. Naqshadani kaliya ma dhimayso qulqulka birlabeedka ee qalloocan laakiin sidoo kale waxa ay wanaajisaa waxtarka beddelka tamarta beddelka, taas oo kor u qaadaysa waxqabadka guud. Naqshadaynta shanta- waxay si wax ku ool ah u xakameysaa iswaafajinta, yaraynaysaa buuqa, waxayna yaraynaysaa khasaaraha kulaylka, hubinta isku halaynta iyo badbaadada hoos yimaada xaaladaha culeyska kala duwan.

Intaa waxa dheer, xidhiidhka Y{0}Y ee saddexda-wajiga shanaad- xudunta tiirka waxa uu taageeraa meel marinta dhexdhexaadka ah, kaas oo wanaajinaya maaraynta culaysyada aan dheeli tirnayn iyo{3}} khaladaadka wareegga gaaban.

2500 kVA three phase pad mounted transformer iron core
 

 

2.2 Kulanka ugu dambeeya

1. Kordhinta Qaybta Firfircoon ee Haamaha Saliidda:Kor u qaad qaybta firfircoon ee beddelka (core and windings) oo dhig haanta saliidda.

2. Isku xirka Korontada:Ku xidh dabaylaha iyo baadiyaha, adiga oo hubinaya isku xidhka aaminka ah oo wanaagsan-

3. Rakibaadda Agabka:Ku rakib qalabyada, oo ay ku jiraan saddex qiyaasood iyo hal waalle, oo ay la socdaan qaybaha kale ee la xidhiidha.

4. Xakamaynta Haamaha Shidaalka:Xir haanta saliidda oo ku buuxi saliidda beddelka si ay u daboolaan una qaboojiyaan.

2500 kVA three phase pad mounted transformer final assembly

03 Tilmaamaha Deegaanka

2500 kVA pad mounted transformer stainless steel tank
01

Haanta birta-la'aanta ah - Cimri dheer, Qashin yar

Taangiga birta ah ayaa u adkaysata daxalka, waxay u adkaysataa xaaladaha adag ee dibadda, waxay kordhisaa nolosha adeeg ka baxsan birta caadiga ah, waxay yaraynaysaa beddelka iyo qashinka, waxayna ahaanaysaa mid dib loo warshadayn karo.

02

Baadhista Cilada Gudaha (IFD) 

IFD waxay la socotaa isbeddelada gudaha iyo digniinaha goor hore, ka hortagga daadadyada, waxyeelada qalabka, iyo khataraha deegaanka ka hor intaysan kordhin.

Internal Fault Detector (IFD) 
Aluminum Windings
03

Dabaysha Aluminiumka - Sawir Kaarboon Ka Fudud

Dabaylaha aluminiumku waxa ay isticmaalaan tamar ka yar si ay u soo saaraan naxaasta, u kala daadiyaan kulaylka si hufan, u yareeyaan raadka kaarboonka, oo ay taageeraan waxtarka beddelka muddada dheer-

 

04 Tijaabinta

Maya

Shayga Tijaabada

Unug

Qiimaha Ogolaanshaha

Qiimaha la qiyaasay

Gabagabo

1

Cabbiraadaha iska caabinta

%

Qiyaasta dheelitir la'aanta iska caabbinta ugu badan

2.43

Gudub

2

Imtixaanada saamiga

%

Weecashada saamiga danab ee taabashada maamulaha: In ka yar ama la mid ah 0.5%

0.03-0.05

Gudub

3

wajiga- imtixaanada xidhiidhka

/

YNyn0

YNyn0

Gudub

4

Maya- khasaarooyinka rarida iyo xamaasadda hadda

/

I0:: bixiyaan qiime la qiyaasay

0.26%

Gudub

P0: Bixi qiimaha la qiyaasay (20 darajo)

2.302kW

U dulqaadasho la'aanta rarka waa +10%

/

5

Load khasaaraha danab impedance iyo hufnaan

/

t:85 darajo

Dulqaadku waa ± 7.5%

Dulqaadka wadarta rarka luminta waa +6%

/

Gudub

Z%: qiimaha la qiyaasay

5.79%

Pk: qiimaha la qiyaasay

16.196kW

Pt: qiimaha la qiyaasay

18.498kW

Waxtarka aan ka yarayn 99.53%

99.53%

6

Tijaabada Korantada ee La dabaqay

kV

LV: 10kV 60s

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

7

Tijaabada adkaysiga korantada ee keentay

kV

Danab la dabaqay (KV):

2 Uur

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

Muddada:60

Soo noqnoqda (HZ): 120

8

Tijaabada daadinta

kPa

Cadaadiska la dabaqay: 20kPA

Muddada:12h

Wax daadsan iyo maya

Waxyeello

Gudub

9

Cabbirka iska caabinta dahaarka

HV -LV ilaa Ground

21.6

/

LV-HV ilaa Ground

19.4

HV&LV ilaa Ground

20.9

10

Tijaabada Saliida

/

Xoogga Dielectric;

58.1 kv

Gudub

Nuxurka qoyaanka

9.4 mg/kg

Qodobka Burburinta

0.00211%

Falanqaynta Furan

In ka yar ama la mid ah 0.03

Falanqaynta Chromatography ee Gaaska

/

 

2500 kVA three phase pad mounted transformer test
2500 kVA three phase pad mounted transformer fat

 

 

05 Baakaynta iyo dhoofinta

2500 kVA three phase pad mounted transformer packaging
2500 kVA three phase pad mounted transformer shipping

 

 

06 Codsiga & Faa'iidada Cagaaran

6.1 Dheeraa{1} Faa'iidooyinka Deegaanka

Nolosha adeeg oo dheer waxay ka dhigan tahay beddelaad yar iyo isticmaalka walxaha hoose, taageeraya waaritaanka.

Naqshad hooseeysa -Naqshad lumin ayaa si joogto ah u badbaadisa tamarta, dhimeysa kharashaadka iyo saameynta deegaanka tobanaan sano.

Taangiyada waara waxay yareeyaan beddelka iyo saliidda qashinka, iyaga oo ilaalinaya nadiifinta iyo cagaarka hawlgallada.

IFD waxay ogaataa cilladaha goor hore, ka hortagta daadinta ama waxyeellada waxayna hoos u dhigtaa khataraha deegaanka.

 

6.2 Xaalado khuseeya

3 phase pad mounted transformer applicable scenarios 1
Jardiinooyinka ganacsiga/warshadaha
3 phase pad mounted transformer applicable scenarios 4
Dhismaha Magaalooyinka
3 phase pad mounted transformer applicable scenarios 2
Nidaamyada Qaybinta Awoodda Dadweynaha

 

 

 

Hot Tags: Transformers pad, saaraha, alaab-qeybiyaha, qiimaha, qiimaha