1250 KVA Transformador Pad Ku rakiban-12.47/0.6 ​​KV|USA 2026

1250 KVA Transformador Pad Ku rakiban-12.47/0.6 ​​KV|USA 2026

Dalka la geynayo: Ameerika 2026
Awoodda: 1250kVA
Voltage: 12.47 / 0.6kV
Feature: Iyadoo hillaaca xidha
U dir sooji

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha ugu kalsoonida badan ee 1250 kva transformador pad ku rakiban -12.47/0.6 ​​kv|USA 2026 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. nala soo xidhiidh wixii faahfaahin ah

 

image003

Utility - Isku halaynta Fasalka ee Dallacaadda EV iyo Isku-dhafka {{1}Isticmaal Mashaariic

 

 

01 Guud

1.1 Sharaxaada Mashruuca

Sannadkii 2026, qandaraasle Maraykan ah ayaa dalbaday 1250 kVA saddex weji suuf ah oo ku shuba transformer ah oo loogu talagalay dallacaadda ganacsiga EV iyo mashruuca qaybinta ee isku dhafan - isticmaalka mashruuca qaybinta, halkaas oo xasilloonida qaybinta tamarta bannaanka, badbaadada hawlgalka, iyo muddada dheer{3} isku halaynta muddada ayaa muhiim u ah kharash bixinta maalinlaha ah kaabayaasha iyo hawlgalka xarunta. Transformer-ka waxa lagu rakibay inta u dhaxaysa quudiyaha tamarta ee 12.47 kV iyo goobta 0.6 kV hoose -shabakadda qaybinta korantada. Transformer-ka waxaa loo soo saaray si waafaqsan IEEE Std C57.12.34 -2022 heerarka, oo leh danab lagu qiimeeyay 12.47 kV GrdY / 7.2 kV ilaa 0.6 kV Y / 0.347 kV, KNAN qaboojinta, YNyn0 kooxda vector, aluminium dabaylaha 75%, iyo 5. halka 99.45% nashqadeynta hufnaanta DOE ay ka caawisay yaraynta muddada dheer{20}khasaaraha hawlgalka ee xaaladaha rarida ganacsiga ee joogtada ah. Dareeraha dahaadhka FR3 ayaa loo doortay si loo hagaajiyo badbaadada dabka iyo waxqabadka deegaanka ee dadweynaha bannaanka{22}} gelitaanka meelaha rakibaadda Si loo hagaajiyo xasiloonida hawlgalka ee culaysyada dallacaadda isbedbeddelaya iyo hillaaca- xaaladaha u nugul, 1250 kVA transformador pad ku rakiban waxay ansixiyeen saddex waji oo shan ah{25} qaab dhismeedka xudunta lugaha ee waxqabadka magnetic dheellitiran iyo xasilooni dhexdhexaad ah, oo ay weheliso xidhidayaasha isku dhafan ee hillaaca, baararka dhulka dhigista, ilaalinta fiyuuska bayoolada, iyo kor u qaadida culayska dabacsanaanta ee afarta badbaadada dayactirka guud ahaan nidaamka qaybinta.

 

 

 

1.2 Tilmaamaha Farsamada

1250 kVA transformador pad ku rakiban tilmaanta iyo xaashida xogta

loo geeyey
Ameerika
Sannadka
2026
Nooca
Saddex weji suuf Buur Transformer
Heerka
IEEE Std C57.12.34-2022
Awood lagu qiimeeyay
1250 kVA
Soo noqnoqda
60HZ
Quudinta
Loop
Hore
dhintay
Marxaladda
saddex
Nooca qaboojinta
KNAN
Insulant dareere ah
FR3 Saliid
Korantada aasaasiga ah
12.47 kV GrdY / 7.2 kV
Voltage Secondary
0.6 kV Y / 0.347 kV
Kooxda Vector
YNyn0
Qalabka dabaysha
Aluminium
Caqabada
5.75%
Waxtarka iyo khasaaraha Heerka
99.45 % Waxtarka DOE
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
1410 W
Load Lumista
9050 W
Agabka
danab xidhe

 

1.3 Sawirro

1250 kVA transformador pad ku rakiban sawir iyo magac

image005 image007

 

 

02 Wax-soo-saarka

2.1 Shan -Xudunta Lugaha

image009
image011

Transformer-ku waxa uu qaatay saddex waji shan - qaab dhismeedka xudunta u ah lugta si loo hagaajiyo dheelitirka qulqulka magnetic, xasiloonida korantada, iyo waxqabadka dhexdhexaadka ah ee hoos yimaada xaaladaha rarida aan toosnayn iyo kuwa aan dheeli tirnayn ee sida caadiga ah laga helo kaabayaasha dallacaadda ganacsiga. Sare - darajada CRGO silikon birta dahaadhida ayaa loo isticmaalay in lagu dhimo wax - lumitaanka culayska iyo buuqa shaqada, halka qaab dhismeedka adag ee isku xidhka uu wanaajiyay xasiloonida makaanikada inta lagu jiro gaadiidka iyo xaaladaha khaladka.

 

2.2 Naqshadaynta Dabaylaha

Nidaamka dabaysha waxa uu isticmaalay kirishbooyada aluminium ee loogu talagalay waxqabadka kulaylka la isku halayn karo, nidaaminta danab xasiloon, iyo kharash {{0}wax ku ool ah oo dheer{1}}howlgal muddada dheer ee nidaamyada qaybinta Waqooyiga Ameerika. Qaab dhismeedka dahaarka ayaa la hagaajiyay si uu ula xidhiidho aaladaha ilaalinta qallafsan iyo xaaladaha shaqada ee bannaanka, halka 12.47 kV ilaa 0.6 kV qaabaynta dabaysha ay taageertay baahida culayska ganacsi ee joogtada ah iyada oo la wanaajiyay isku hallaynta dielectric iyo xakamaynta heerkulka.

image013

 

2.3 Waxtarka DOE

image015

Qaybtan 1250 kVA transformador suuf ku rakiban waxaa loogu talagalay in lagu gaaro 99.45% hufnaanta DOE, taasoo gacan ka geysata dhimista kharashyada hawlgelinta muddada dheer iyo khasaaraha tamarta dhammaan codsiyada qaybinta ganacsiga ee joogtada ah. Iyada oo la wanaajinayo khasaaraha asaasiga ah, luminta culeyska, iyo waxqabadka kulaylka si wada jir ah, transformer-ku waxa uu ilaaliyaa waxtarka xasilloon marka la eego isbedbeddelka ku dallaca EV iyo dhisidda shuruudaha baahida awoodda.

 

2.4 Ilaalinta Sare & Dhulka

image017
image019

Xirayaasha hillaaca isku dhafan iyo baararka dhulka dhigista qolka ayaa si wada jir ah loo nashqadeeyay si ay u bixiyaan dariiq hoose oo wax ku ool ah - caqabad ku ah daah-furnaanta, ka caawinta ilaalinta dahaarka tafatirka iyo qalabka xasaasiga ah ee dallacaadda EV dhacdooyinka ku meel gaarka ah.

 

2.5 Ilaalinta Haamaha

Transformer-ku waxa uu qaatay bakhti {{0} hore - qaab dhismeedka haanta quudinta looguna talagalay in lagu shaqeeyo fiilada dhulka hoostiisa oo badbaado leh iyo muddada dheer{2}} isku halaynta adeega dibadda Rinjiga cad ee dahaarka leh ee budada ah (RAL 9003) ayaa hagaajiyay caabbinta daxalka iyo hoos u dhigista kulaylka qoraxda ee meelaha rakiban ee bannaanka ah.

image021

 

 

03 Tijaabinta

image023
image025

Heerka Imtixaanka

image027

Natiijooyinka Imtixaanka

image029

image031

 

 

04 Baakadaha iyo gaadiidka

4.1 Baakad

image033
image035

Transformer-ku wuxuu leeyahay cabbir guud oo is haysta oo ah 1680 × 1580 × 1880 mm, oo leh ku dhawaad ​​1000 litir oo saliid dahaadh ah iyo wadarta culeyska hawlgalka ee 4000 kg, taasoo bixisa isku-dheelitirka isku dheelitiran ee dabacsanaanta rakibaadda, xasilloonida kuleylka, iyo waxqabadka hawlgalka dibadda waara.

 