100 kVA Beddelka Cirifka Taleefanka-34.5/0.24 kV|USA 2023

100 kVA Beddelka Cirifka Taleefanka-34.5/0.24 kV|USA 2023

Dalka: Ameerika 2024
Awoodda: 100kVA
Voltage: 34.5/0.24kV
Feature: oo leh qalab fudud
U dir sooji

 

 

100 kVA telephone pole transformer

Mida{0}}Tiirka Wajiga{1}ku rakiban Transformer: Ka faa'iidaysiga tamarta caqliga, oo u horseedaysa dariiqa sare ee awooda.

 

01 Guud

1.1 Asalkii Mashruuca

Tani 100kVA hal weji hal tiir ku rakiban transformer waxaa la geeyey America 2023. Awoodda lagu qiimeeyay ee Transformer waa 100 kVA, danab aasaasiga ah iyo labaad ee transformer waa 19.92/0.24 kV. Transformer-ka waxa loo nashqadeeyay in lagu daro tignoolajiyada horumarsan iyo agab tayo sare leh -, kaas oo gacan ka geysan kara waxqabadkiisa la isku halayn karo iyo cimriga hawlgelinta ee la dheereeyey.

Hal abuurka joogtada ah, weynaynta iyo macaamilka{0}xalalka ku jihaysan, transformer ay soo saartay SCOTECH ayaa ka shaqeeyay aduunka oo dhan. Waxaan hubineynaa in mid kasta oo ka mid ah cutubyada nala keenay uu maray imtixaan adag oo aqbalaad ah. Waxaan bixinaa hal - adeeg xirmo laga bilaabo la talinta, xigashada, wax soo saarka, rakibida, hawlgelinta, tababarka ilaa adeegyada iibka kadib, badeecadayada ayaa hadda ka shaqeeya in ka badan 50 wadan oo aduunka ah. Waxaan hiigsaneynaa inaan noqono alaab-qeybiyahaaga ugu kalsoonida badan iyo sidoo kale lamaanahaaga ugu fiican ganacsiga!

 

1.2 Tilmaamaha Farsamada

100 kVA hal weji tiir ku rakiban tafatirka tafatirka iyo xaashida xogta

loo geeyey
Ameerika
Sannadka
2024
Qaabka
100kVA-19.92/0.24(0.12)kV
Nooca
Tiir hal waji ah oo ku rakiban transformer
Heerka
CSA C2.2
Awood lagu qiimeeyay
100kVA
Soo noqnoqda
60HZ
Marxaladda
Keli
Nooca qaboojinta
ONAN
Korantada aasaasiga ah
34.5Grdy/19.92kV
Voltage Secondary
0.24/0.12kV
Kooxda Vector
Li0
Polarity
Kala goyn
Caqabada
2.7%
Taabo Beddelka
NLTC
Riixista Range
± 2 * 2.5% oo leh NLTC
Wax Xamuul ah ma jiro
0.225KW
Load Lumista
1.375KW
Agabka
Habaynta caadiga ah
Hadallo
N/A

 

1.3 Sawirro

100 kVA hal waji oo tiir ku rakiban jaantuska jaantuska iyo cabbirka

100 kVA telephone pole transformer drawing 100 kVA telephone pole transformer nameplate

 

 

02 Wax-soo-saarka

2.1 Core

Qaab dhismeedka ugu muhiimsan ee xudunta gariiradda ayaa ah in xudunta guud ahaan tahay hal unug, oo ka kooban lakabyo badan oo cajalad bir ah oo dhumucdeedu tahay<0.35mm, wound one or more times. The coil of coil core transformer usually adopts a coaxial coil structure. By strengthening the magnetic circuit and adjusting the voltage ratio of coil, the transformer's electrical parameters can be changed. Because the coil core is wound along the best magnetic direction of the oriented silicon steel sheet, it fully gives full play to the superior performance of the oriented silicon steel sheet, the magnetic flux direction is completely consistent with the orientation of the silicon steel sheet, the overload capacity is strong, and the magnetic circuit distortion is small, so the no-load loss and no-load current are smaller than the laminated iron core (the laminated iron core will have magnetic circuit distortion because of the laminated joint).

100 kVA telephone pole transformer wound core

 

2.2 Dabaylaha

100 kVA telephone pole transformer winding

Dabaylaha bireedku wuxuu ka kooban yahay xaashi bireedyo is barbar socda, oo badanaa laga sameeyo naxaas ama aluminium. Foil-yadani waa kala fog yihiin oo way is dhex galeen si ay u sameeyaan qaab-dhismeedka dabaysha. Naqshadeyntani waxay ka dhigaysaa dabaylaha bireedku inay si fiican u daadiyaan kulaylka marka la hoosgeliyo hadda sare, laakiin sidoo kale waxay yaraynaysaa caabbinta iyo inductance ee dabaysha, waxayna hagaajinaysaa waxqabadka korantada ee dabaysha. Tilmaamaha ugu weyn ee dabaylaha foilku waa in lagu duubo mashiinka dabaysha ee gaarka ah, kaas oo leh heer sare oo otomaatig ah oo bixiya wax soo saar sare iyo tayada alaabta. Wareegtada, taas oo ah, awoodda dhexda iyo dhererka dhererkeedu waa weyn yahay, xagasha wareega waa la tirtiray, gaaban{4}} iska caabbinta wareegga wareegga waa xoog badan tahay, xoogga makaanikada ayaa sarreeya, dhismuhu waa ku habboon yahay, cilladaha axial iyo radial waa yar yihiin, cabbirka joomatari waa sahlan tahay in la hubiyo, leexashadu waa yara cidhiidhi, ma fududa in la helo goobooyin siman. Wareegga bireedku wuxuu kaloo yarayn karaa dheecaanka qayb ahaan wuxuuna wanaajin karaa waxqabadka dahaarka ee dabaysha.

 

2.3 Haanta

Shirkadeena waxay u isticmaashaa birta aan tayada lahayn - oo ah alaabta ceeriin ee soo saarista haamaha shidaalka, waxayna isticmaashaa mishiinada haydarooliga ama qalabka kale ee samaynta si ay u laaloosho, u jarto oo ugu cadaadiso saxanka birta qaabka la rabo ee haanta shidaalka. Dabada qaybaha oo samee alxanka gaashaanka gaaska ama hababka alxanka kale si loo hubiyo cidhiidhiga iyo xoogga qaabdhismeedka taangiga. Dhammaan shaabadihii waxa lagu xidhay xadka ugu dambeeya; Qaybaha birta ah ee gudaha iyo dibadda santuuqa ayaa lagu soo koobay si ay timaha uga saaraan, iyo tolitaanka alxanka iyo shaabadda ayaa la tijaabiyaa saddex jeer (fluorescence, cadaadis togan, tijaabada daadinta cadaadiska xun); Rinjiga waxaa loo sameeyay si waafaqsan heerka caadiga ah ee ka-hortagga{3} shuruudaha miridhku.

100 kVA telephone pole transformer stainless plate oil tank

 

2.4 Kulanka ugu dambeeya

100 kVA telephone pole transformer assembly

1. Isku-dhafka muhiimka ah: Isku-dhafka asaasiga ah ee transformer-ka tiirka wuxuu ku urursan yahay saldhigga beddelka ama jir go'an iyadoo loo eegayo shuruudaha naqshadeynta.

2. Isku-xidhka dabaysha: Siligga dabaysha ee qeexid gaar ah ayaa ku dhaawacmay xudunta birta ee transformer-ka iyadoo loo eegayo shuruudaha naqshadaynta, oo ay ku jiraan dabaysha aasaasiga ah iyo dabaysha sare. Isticmaal dahaarka si aad u go'doomiso gariiradaha dabaylaha.

3. Daawaynta dahaarka: dabayshu waa la dahaadhay, oo ay ku jiraan daweynta rinjiga dahaadhka ah iyo dubista, si loo hubiyo waxqabadka dahaarka ee wanaagsan.

4. Ku rakib qaybo kale: sida haanta shidaalka, qiyaasta heerka saliidda, qalabka sii daaya gaaska, qaboojiyaha, iwm.

5. Insulation oil cirbad: Saliida dahaadhka waxa lagu duraa haanta saliida transformerka si ay u buuxiso booska gudaha ee transformer-ka iyo in la hubiyo in dhererka heerka saliidu buuxiyo shuruudaha.

 

 

03 Tijaabinta

Waxaan sameynaa tiro tijaabo ah si loo hubiyo tayada badeecada iyo waxqabadka, imtixaanada ugu muhiimsan waxaa ka mid ah:

1. Tijaabada dahaadhka dabaysha: Waxqabadka dahaadhka ee dabaylaha ayaa la tijaabiyay, oo ay ku jiraan tijaabada caabbinta dabaysha ee u dhaxaysa dabaylaha, cabirka lumista dielectric iyo tijaabada dheecaanka qayb ahaan.

2. Tijaabada danab sare: Tijaabada tamarta sare ee u dhaxaysa dabaylaha, inta u dhaxaysa dabaylaha iyo dhulka, iyo inta u dhaxaysa dabaylaha iyo xargaha birta si loo hubiyo kalsoonida dahaarka iyo ka hortagga burburka.

3. Maya{1}Tijaabada culayska: tijaabi danab la qiimeeyay si aad u cabbirto maya{2}}load lumin iyo maya{3}}load hadda ee danab la qiimeeyay, hubi in isku xidhka magnetka iyo birta luminta transformerku ay buuxinayaan shuruudaha naqshadaynta.

4. Tijaabada culeyska: tijaabi culeyska la qiimeeyay si loo ogaado waxqabadka guud ee transformer-ka, oo ay ku jiraan luminta, kor u kaca heerkulka, waxqabadka nidaaminta korantada, iwm.

5. Tijaabada gaaban -Tijaabada wareegga: gaaban -voltka wareegga gaaban iyo gaaban - waayida wareegga wareegga wareegga waxa la tijaabiyaa si loo xaqiijiyo waxqabadka gaaban - waxqabadka wareegga iyo xasilloonida kulaylka taransfooriyaha.

6. Tijaabada tayada saliidda dahaadhka: luminta dielectric, qiimaha acid, nuxurka biyaha iyo tijaabooyin kale ayaa lagu sameeyaa saliidda dahaadhka si loo hubiyo in tayada saliidda dahaadhka ay buuxinayso shuruudaha caadiga ah.

7. Kormeerka muuqaalka: Hubi muuqaalka transformer-ka si aad u hubiso inay jiraan daadinta saliidda, qallafsanaanta, dabacsanaanta iyo dhibaatooyinka kale ee haanta shidaalka, dabaysha iyo qaybaha dahaarka.

 

100 kVA telephone pole transformer tesing
100 kVA telephone pole transformer routine test

 

 

04 Baakaynta iyo dhoofinta

100 kVA telephone pole transformer wooden packing
100 kVA telephone pole transformer shippment

05 Goobta iyo Kooban

Tiirka kaliya ee -{1}Transformer-ka lagu rakibay, oo leh hufnaantiisa sare, tamar{2}} badbaadinta waxqabadkiisa, hawlgal la isku halayn karo, iyo rakibaadda iyo naqshadaynta fudud, waxa ay noqotay qayb lagama maarmaanka u ah shabakadaha awood qaybinta casriga ah. Haddi lagu dabaqo awood qaybinta magaalooyinka iyo miyiga ama xaaladaha warshadaha, waxay siisaa macaamiisha taageero koronto oo tayo sare leh - Adigoo na dooranaya, waxaad heli doontaa badeecooyin la aamini karo iyo dammaanad adeeg xirfadeed, adigoo ka wada shaqeynaya horumarinta iyo cusboonaysiinta xadhkaha korantada ee caqliga leh!

100 kVA telephone pole transformer with arrester

 

Hot Tags: Transformer tiirka taleefanka, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha