50 kVA Transformer Dusha Korontada-7.97/0.12/0.24 kV|Kanada 2024

50 kVA Transformer Dusha Korontada-7.97/0.12/0.24 kV|Kanada 2024

Dalka la geeyey: Kanada 2024
Awoodda: 50kVA
Voltage: 7.97/13.8Y-0.12(0.24)kV
Feature: Amorphous core
U dir sooji

 

 

50 kva transformer on power pole-front-view

Transformer ah oo la isku halayn karo oo ku yaal tirka korantada oo keenaya tamar hufan oo deggan bulshooyinka casriga ah

 

01 Guud

1.1 Sharaxaada Mashruuca

Tani waa 50 kVAhal - tiirka wejiga - ku rakiban qalabka qaybintasi adag ugu hoggaansan heerarka IEEE C57.12.20. Waxa si weyn looga isticmaalaa shabakadaha qaybinta Waqooyiga Ameerika, oo sida caadiga ah lagu rakibay 13.8 kV oo salka ku haya -nidaamka wye, halkaasoo taransfooriyuhu uu ku xidhan yahay wejiga{4}}ilaa- dhexdhexaad ah 7.97 kV wuxuuna bixiyaa kala qaybsanaan la isku halayn karo 120/240 V -wax soo saar weji oo loogu talagalay guryaha iyo codsiyada ganacsiga fudud.

Transformer-ka 50 kVA ee ku yaala tiirka korantada waxa uu qaataa xudunta birta ah, kaas oo si weyn u yareynaya wax - lumin oo kaliya 0.043 kW. Waxay ku siinaysaa tamar aad u wanaagsan{4}}badbaadinta waxqabadka xitaa marka uu culays fudud yahay. Iyada oo la qiimeeyay xannibaadda 2.1%, Transformer-ku waxa uu bixiyaa habayn danab wanaagsan iyo, ay weheliso ± 2×2.5% maya{9}}loaderiyaha tuubada, waxay hubisaa danab sare oo deggan gudaha ±5% ee magaca.

Astaamaha naqshadeeda waxaa ka mid ah qaboojinta dabiiciga ah ee ONAN, dabaylaha aluminiumka, iyo polarity dheeri ah, oo leh kooxda vector Ii6. Astaamahani waxay ka dhigaan transformer-ka is haysta. Waa wax ku ool ah oo lagu kalsoonaan karo isticmaalka tiirka - Cutubku waxa uu leeyahay madaxa soo xidhida qalliinka. Tani waxay fududaynaysaa in lagu daro qalabka ilaalinta.

Transformer-ku wuxuu leeyahay khasaare yar. Waxay la shaqeysaa hufnaan sare. Waxa kale oo ay si fiican ula qabsanaysaa baahiyaha kala duwan. Tani waxay ka dhigaysaa doorasho wanaagsan hababka qaybinta awoodda casriga ah.

 

 

 

1.2 Tilmaamaha Farsamada

Transformer 50kVA ah oo ku saabsan tiirka tamarta iyo xaashida xogta

loo geeyey
Kanada
Sannadka
2024
Nooca
Tiir hal waji ah oo ku rakiban transformer
Heerka
IEEE C57.12.20
Awood lagu qiimeeyay
50 kVA
Soo noqnoqoshada
60HZ
Polarity
Wax lagu daro
Kooxda Vector
II6
Korantada aasaasiga ah
7.97/13.8Y kV
Voltage Secondary
120/240 V
Qalabka dabaysha
Aluminium
Caqabada
2.1%
Habka qaboojinta
ONAN
Taabo Beddelka
NLTC
Riixista Range
±2X2.5%
Wax Xamuul ah ma jiro
0.043 kW
Load Lumista
0.5 kW
Agabka
Madaxii qalliinka xidhay

 

 

1.3 Sawirro

Transformer 50kVA ah oo ku yaal sawirka tiirka korantada iyo warqadda magaca

50 kva transformer on power pole-technical-drawing 50 kva transformer on power pole-nameplate

 

 

02 Wax-soo-saarka

2.1 Core

The tirka -ku rakiban transformerwaxa uu leeyahay xudunta birta amorphous, oo laga sameeyay dhalaalka birta, boron, silicon, nikkel, iyo carbon. Marka la barbar dhigo qabowga caadiga ah{1} birta silikoon duuban, xuduntani waa isotropic, aad u khafiif ah (0.03 mm), oo leh adkaysi sare oo koronto ah, si weyn u yaraynaysa khasaaraha hadda jira. Waxay ku guulaysataa wax-qabad aad u hooseeya oo aan- lumin (0.043 kW) iyo luminta culayska (0.5 kW), oo bixisa hufnaan sare, wax soo saar la fududeeyay, iyo hawl-saaxiibtinimo-

50 kva transformer on power pole-amorphous-metal-iron-core

 

2.2 Dabaylaha

50 kva transformer on power pole-aluminum-winding

Halbeegyadayada - tiirka wejiga -ku-dhajislayaasha rakiban waxa ka muuqda gariiradaha foil voltage hoose - Macaamiisha dooranaya aluminium gariiradaha LV waxay ka faa'iideysteen dhimista miisaanka iyo qiimaha, iyagoo ilaalinaya isku halaynta la midka ah iyo nolosha hawlgalka ilaa naxaasta. Gariiradaha siliga korantada sare{6}

 

2.3 Haanta

Tan hal -Taangiga shidaalka cylindrical wejiga waxa laga dhisay bir khafiif ah, iyada oo daboolka iyo hooseba la sameeyay iyada oo la adeegsanayo habka sawirida xaashida khafiifka ah. Ku qalabaysan laba bushings HV on daboolka iyo saddex LV bushings indhaha ee darbiga dhinac, naqshadeeda si buuxda u shaabadeeyey waxay hubisaa iska caabin sare ee daadinta iyo isku halaynta hawlgalka.

50 kva transformer on power pole-oil-cylindrical-fuel-tank

 

2.4 Kulanka ugu dambeeya

50 kva transformer on power pole-final-assembly

Sida loo rakibo gariiradda iyo xudunta nabarka: Marka hore, dhig dabaqa ugu horreeya ee C - (furan isagoo u jeeda sida "U"). Qaado gariiradda oo si buuxda gacanta ugu dheji daloolkeeda dhexe hal lug oo xudunta ah, adigoo hoos u riixaya xagga hoose. Qaado C - xudunta labaad, ku toosi gooynteeda si sax ah iyo goynta xudunta koowaad. Si tartiib ah u xir ilaa labada qaybood ay si buuxda isu noqdaan. Ku rakib taarikada xajinta ee sare iyo hoose, geli boolal dhaadheer.

 

 

03 Tijaabinta

Imtixaanka joogtada ah

1. Cabbiraadaha iska caabinta

2. Imtixaanada saamiga

3. Wajiga{1}}Tijaabada xidhiidhka

4. Wax Khasaare ah oo Xamuul ah oo Hadda socda ma jiro

5. Lumitaanka Culayska, Korantada Waxyeelaynta iyo Hufnaanta

6. Tijaabada Voltage ee la dabaqay

7. Tijaabada adkaysiga korantada ee keentay

8. Tijaabada Diidida oo leh Cadaadis loogu talagalay beddelayaasha Dareeraha Immersed

9. Cabbirka iska caabbinta dahaarka

10. Tijaabada Dielectric Oil

11. Tijaabada Hilaaca

 

50 kva transformer on power pole-routine-test-leakage-test
50 kva transformer on power pole-routine-test-applied-voltage-test

 

Natiijooyinka Imtixaanka

Maya

Shayga Tijaabada

Unug

Qiimaha Ogolaanshaha

Qiimaha la qiyaasay

Gabagabo

1

Cabbiraadaha iska caabinta

%

/

/

Gudub

2

Imtixaanada saamiga

%

Weecashada saamiga danab ee taabashada maamulaha: In ka yar ama la mid ah 0.5%

Astaanta isku xirka: II6

0.02

Gudub

3

wajiga- imtixaanada xidhiidhka

/

Wax lagu daro

Wax lagu daro

Gudub

4

Maya- khasaarooyinka rarida iyo xamaasadda hadda

 

%

kW

t:85 darajo

I0 :: bixiyaan qiime la qiyaasay

P0: bixi qiimaha la qiyaasay

Dulqaadka wax qabad la'aan waa +10%

1.11(100%)

2.16(105%)

0.045(100%)

0.061(105%)

Gudub

5

Load khasaaraha danab impedance iyo hufnaan

%

kW

kW

t:85 darajo

Z%: qiimaha la qiyaasay

Pk: qiimaha la qiyaasay

Pt: qiimaha la qiyaasay

dulqaadka impedance waa ± 10%

dulqaadka wadarta rarka luminta waa +6%

2.21

0.496

0.543

99.37

Gudub

6

Tijaabada Korantada ee La dabaqay

kV

HV: 34kV 60s

LV: 10kV 60s

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

7

Tijaabada adkaysiga korantada ee keentay

kV

Danab la dabaqay (KV):

15.94

Muddada:40

Inta jeer (HZ): 150

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

8

Tijaabada daadinta

kPa

Cadaadiska la dabaqay: 20kPA

Muddada:12h

Wax daadsan iyo maya

Waxyeello

Gudub

9

Cabbirka iska caabinta dahaarka

HV&LV ilaa Dhulka:

120.0

/

HV -LV ilaa Ground

51.8

LV-HV ilaa Ground

62.6

10

Tijaabada Dielectric Oil

kV

Ka weyn ama la mid ah 45

55.48

Gudub

11

Tijaabada dareenka hillaaca

kV

mawjad buuxda, hirka badh

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

 

 

04 Baakaynta iyo dhoofinta

50 kva transformer on power pole-export-packing
50 kva transformer on power pole-delivery

 

 
 

05 Goobta iyo Kooban

Midkan 50 kVA ee kali ah -cirka wejiga{2}}ku dhejiyay taransfooriyaha waxa loo sameeyay Kanada 2024. Waxa ay raacdaa IEEE C57.12.20. Waxay ku shaqeysaa 13.8kV oo saldhig ah- nidaamyada wye, oo siinaya 120/240 V guryaha iyo ganacsiyada yaryar.

Transformer-ku waxa uu leeyahay xudunta birta oo amor-ka. Waxay haysaa wax - khasaare ah 0.043 kW iyo luminta 0.5 kW. Waxay kaydisaa tamarta waxayna ku socotaa waxtar sare leh. Dabaysha aluminiumka, qaboojinta ONAN, iyo dabaylaha wax lagu daro waxay ka dhigaan cutubka mid cufan, badbaado leh, oo la isku halayn karo. Madaxa xiraha qalliinka ayaa ogolaada hagaajinta ilaalinta sahlan.

Transformer-kan ku shaqeeya tiirka korontada waxa uu isku daraa hufnaanta, isku halaynta, iyo deegaanka{0}waxqabadka saaxiibtinimo, taas oo ka dhigaysa doorasho adag shabakadaha qaybinta casriga ah.

Scotech waxay u samaysaa transformers tayo leh macaamiisha caalamka. Alaabtayadu waxay badbaadiyaan tamarta, gooyaan khasaaraha, waxayna bixiyaan awood deggan. Waxaan bixinaa xalal badbaado leh oo la xaqiijiyay kuwaas oo ka caawiya korontadu inay si fiican u shaqeeyaan maalin kasta.

Scotech - Transformers la isku halayn karo, awood hufan, shabakado wanagsan

50-kva-pole-mounted-transformer-left-45-degree-view

Hot Tags: Transformer On Pole Korontada, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha