75 kVA Transformer Dusha tiirka-13.8/0.347 kV|Kanada 2025
Awoodda: 75 kVA
Voltage: 13.8/0.347kV
Feature: oo leh madaxa xiraha qalliinka

Kordhinta Qaybinta Korontada - Ka Xariifsan, Ka Dhakhsiyaha Badan, Xalalka Ku Xidhan Tiirka Cagaaran.
01 Guud
1.1 Sharaxaada Mashruuca
75 kVA hal - tiir weji - ku rakiban Transformer ayaa la geeyey Kanada 2025. Waxa ay leedahay qaboojinta ONAN, danab hoose oo ah 13.8 kV oo leh ±2×2.5% maya-load tap changer (NLTC), iyo koronto labaad oo ah 0.347 kV, samaynaysa koox I6.
Cirifka -Transformers-ku rakiban ee kan oo kale ah waa qaybaha muhiimka ah ee shabakadaha qaybinta korontada Waxay hoos u dhigaan -koronta sare ee korantada si ay u badbaadiyaan, heerar la isticmaali karo guryaha, ganacsiyada yaryar, iyo goobaha warshadaha fudud. Ku rakiban tiirarka tamarta, waxay keenaan koronto la isku halayn karo-xataa xaafadaha ku hareeraysan iyo miyiga, halkaas oo khadadka dhulka hoostiisa ay yihiin kuwo aan macquul ahayn.
Transformer-kani waxa uu u fiican yahay kooxo la dego, dukaamo yaryar, beero, iyo tas-hiilaadyo fogfog, sida xarumaha isgaadhsiinta ama goobaha adeega deegaanka. Xilliga ugu sarreeya, sida baahida kuleylka jiilaalka, iyo duufaannada marmarka qaarkood waxay ka dhigaan awood joogto ah oo muhiim ah. Naqshadeeda is haysta, ee adag ayaa ka dhigaysa rakibaadda mid toos ah, halka khasaaraha yar iyo dabaylaha aluminiumka ee waara ay dayactirka ugu yareeyaan.
Iyada oo ay diiradda saarayso isku halaynta, badbaadada, iyo hufnaanta, cutubkani waxa uu taageeraa shabaqyada soo koraya, waxa ay xoojisaa xasiloonida shabakada maxaliga ah, oo xataa dejisa {{0}miisaanka is dhexgalka tamarta la cusboonaysiin karo. Waxaa loogu talagalay in lagu bixiyo la isku halayn karo, awood ammaan ah -sanadka-oo dhan, oo ku baahsan deegaanno kala duwan.
1.2 Tilmaamaha Farsamada
75 kVA tiirka ku rakiban qalabka beddelka nooca iyo xaashida xogta
|
loo geeyey
Kanada
|
|
Sannadka
2025
|
|
Nooca
Transformer ku rakiban tiirarka
|
|
Heerka
CSA C2.2-06
|
|
Awood lagu qiimeeyay
75 kVA
|
|
Soo noqnoqoshada
60HZ
|
|
Marxaladda
1
|
|
Polarity
Wax lagu daro
|
|
Nooca qaboojinta
ONAN
|
|
Korantada aasaasiga ah
13.8 kV
|
|
Voltage Secondary
0.347 kV
|
|
Qalabka dabaysha
Aluminium
|
|
barokaca xagal
II6
|
|
Caqabada
2%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Wax Xamuul ah ma jiro
0.060 kW
|
|
Load Lumista
0.810 kW
|
1.3 Sawirro
75 kVA tiirka ku rakiban jaantuska beddelka sawirka iyo cabbirka.
![]() |
![]() |
02 Wax-soo-saarka
2.1 Core
Xudunta amorphous-ku waxay bixisaa ultra{0}}hoose - (70% in ka yar silikoon birta) oo u dhaw - qasaaraha eddy hadda Naqshadaynta nabarkeeda fudud ee adag waxay hubisaa waxqabadka birlabeed ee ugu fican ee tiirka - codsiyada rakiban, oo keenaya waxtarka tamarta qaybsiga

2.2 Dabaylaha

Tiirkan -Transformer-ka rakiban waxa uu shaqaaleeyaa nakhshad dabaylo la hagaajiyay: foil aluminium ah oo hooseeya-labaydhka korantada (qiimaha{2}}oo wax ku ool u leh kulaylka wanaagsan) iyo silig naxaasta ah ee sareeya-korontada korantada ( conductivity sare iyo adkeysiga). Qaabaynta isku-dhafkan waxay hubisaa waxtarka sare, xasilloonida kulaylka iyo waxqabadka lagu kalsoonaan karo ee shabakadaha qaybinta.
2.3 Haanta
Taangiga tiirka -Transformer-ka lagu rakibay caadi ahaan waa qaab dhismeed xidhan oo ka samaysan daxal{1}} taargo bir ah oo adkaysi u leh, oo lagu qurxiyey qaab cylindrical ama leydi ah, iyada oo dusha sare lagu daaweeyay ciid-qarxinta oo lagu dahaadhay rinji lidka ku ah - rinjiga daxalka si uu ugu adkaysto xaaladaha adag ee dibadda. Haanta waxaa ka buuxsamay saliid dahaar ah oo loogu talagalay qaboojinta iyo dahaarka, looguna talagalay inay noqoto mid cufan oo miisaankeedu yar yahay, taangiga ayaa si ammaan ah loogu dhejiyaa baallaha tamarta iyadoo la adeegsanayo biraha alxanka ah ama dhejiska ah.

2.4 Kulanka ugu dambeeya

1. Rakibaadda Dabaysha:U jiid dabaylaha HV/LV xagga xudunta, hubinta isku toosinta dahaarka saxda ah iyo hagaajinta farsamada ee sugan.
2. Isku xirka Korontada:Isku xidhka dabaysha waxay keenaysaa beddelayaasha tuubada, baadiyaha, iyo qaybaha kale, iyagoo xaqiijinaya caabbinta xidhiidhka.
3. Xudunta - Qalajinta gariiradda:Geli qaybta firfircoon ee la soo ururiyey oo geli foornada qallajinta si loogu kululeeyo faakuumka si looga saaro qoyaanka oo loo hubiyo daacadnimada dahaarka.
4. Meelaynta Haamaha:Ku rid qaybta firfircoon ee engegan taangiga, ka dibna ku xidh boolal-saldhig.
5. Rakibaadda Agabka:Buuraha cadaadiska cadaadiska, OCTC, madaxa xiraha qalliinka, xirida dhammaan kala-goysyada.
6. Buuxinta & Xidhida Saliidda:Vacuum-ku buuxi saliidda dahaadhka ilaa heerka la cayimay, samee tijaabooyinka muunada saliida, oo xaqiiji liidashada{1}} adkaynta dhamaystirka isu imaatinka.
03 Tijaabinta
|
Maya |
Shayga Tijaabada |
Unug |
Qiimaha Ogolaanshaha |
Qiimaha la qiyaasay |
Gabagabo |
|
1 |
Cabbiraadaha iska caabinta |
/ |
/ |
/ |
Gudub |
|
2 |
Imtixaanada saamiga |
/ |
Weecashada saamiga danab ee taabashada maamulaha: In ka yar ama la mid ah 0.5% Astaanta isku xirka: II6 |
-0.03 |
Gudub |
|
3 |
Tijaabada polarity |
/ |
Wax lagu daro |
Wax lagu daro |
Gudub |
|
4 |
Maya- khasaarooyinka rarida iyo xamaasadda hadda |
% |
I0 :: bixiyaan qiime la qiyaasay |
0.33 |
Gudub |
|
kW |
P0: Bixi qiimaha la qiyaasay (85 darajo) |
0.048 |
|||
|
(105%)P0: Bixi qiimaha la qiyaasay (85 darajo) |
0.058 |
||||
|
/ |
Dulqaadka wax qabad la'aan waa ± 10% |
/ |
|||
|
5 |
Khasaaraha culeyska, korantada impedance, wadarta khasaaraha iyo hufnaanta |
/ |
t:85 darajo dulqaadka impedance waa ± 15% Dulqaadka wadarta rarka luminta waa ± 6% |
/ |
Gudub |
|
% |
Z%: qiimaha la qiyaasay |
2.03 |
|||
|
kW |
Pk: qiimaha la qiyaasay |
0.740 |
|||
|
kW |
Pt: qiimaha la qiyaasay |
0.791 |
|||
|
% |
Waxtarka aan ka yarayn 98.94% |
99.42 |
|||
|
6 |
Tijaabada Korantada ee La dabaqay |
/ |
LV: 10kV 60s HV: 34kV 60s |
Ma jiro burbur ku yimaada tamarta tijaabada ah |
Gudub |
|
7 |
Tijaabada adkaysiga korantada ee keentay |
/ |
Danab la dabaqay (KV):0.694 |
Ma jiro burbur ku yimaada tamarta tijaabada ah |
Gudub |
|
Muddada:60 |
|||||
|
Soo noqnoqda (HZ): 120 |
|||||
|
8 |
Cabbirka iska caabinta dahaarka |
GΩ |
HV-LV·to·Ground |
120 |
Gudub |
|
LV-HV ilaa Ground |
20.2 |
||||
|
HV&LV ilaa Ground |
20.9 |
||||
|
9 |
Tijaabada daadinta |
/ |
Cadaadiska la dabaqay: 20kPA |
Wax daadsan iyo maya Waxyeello |
Gudub |
|
Muddada:12h |
|||||
|
10 |
Tijaabada Saliida |
kV |
Xoogga Dielectric |
55.7 |
Gudub |
|
mg/kg |
Nuxurka qoyaanka |
9.7 |
|||
|
% |
Qodobka Burburinta |
0.00317 |
|||
|
mg/kg |
Falanqaynta Furan |
0.03 |
|||
|
/ |
Falanqaynta Chromatography ee Gaaska |
/ |


04 Baakaynta iyo dhoofinta
4.1 Xirxirida
Tiirka -Transformer-ka ku rakiban waxa si sugan loogu baakadeeyey sanduuq alwaax adag oo loogu talagalay in uu u adkaysto gaadiidka iyo maaraynta. Sanduuqa alwaaxa ah waxaa lagu dhisay alwaax waara, oo leh geeso la xoojiyay iyo geesaha si loogu daro ilaalinta. Gudaha, transformer-ku si adag ayuu u xidhan yahay iyada oo la isticmaalayo xargaha iyo alaabta barkinta si looga hortago dhaqdhaqaaqa iyo dhaawaca shoogga. Dusha sare ee sanduuqa waxa lagu calaamadeeyay tilmaamaha maaraynta, qeexida miisaanka, iyo calaamadaha jihaynta si loo hubiyo saadka saxda ah.

4.2 dhoofinta

Tiirkan -Transformer-ka ku rakiban waxa si amaan ah loogu xidhi doonaa sanduuq alwaax ah oo habaysan oo leh shoog{1} cadaymo iyo qoyaan{2}baakad u adkaysata, ka dib waxaa lagu rari doonaa gaadhi xamuul ah iyadoo la isticmaalayo fargeetooyin lagu geynayo dekeda. Waxaa lagu soo rari doonaa weel 40ft ah oo caadi ah (huurka{5}}oo lagu xakameynayo saabuunta) iyadoo la raacayo shuruudaha CIF ilaa Dekedda Montreal. Marka la yimaado, sanduuqa waxaa lagu dejin karaa iyada oo la isticmaalayo fargeeto ama wiishash. Caymiska badda oo buuxa (110% qiimaha qaansheegta, Dhammaan Khataraha) ayaa daboolaya dhammaan shixnadaha ilaa 14 maalmood kadib{10}} imaanshaha.
05 Faa'iidooyinka & Faa'iido darrada Cirifka -Transformers rakiban
Tiirarka -Transformers ee ku rakiban waa caan. Waa maxay sababtu? Nolosha adeegga dheer, rakibaadda fudud, waxayna kaliya shaqeeyaan. Waa kuwan waxa ka dhigaya inay soo baxaan:
Codsiyada kala duwan:Guryo, dhismayaal ganacsi oo yaryar, xataa meelaha fog-fog{0}Transformers-yadani way wada qabtaan.
Quwadda Dabacsan:Keliya-wax soo saarka wejigu waa heer. Ma u baahan tahay awood dheeraad ah? Isku dar saddex waji- Fudud
Qiimaha{0}Waxtar leh:Ka jaban saliidda kale -Transformers-ka la quusiyay, haddana wax qabadku waa uu adag yahay.
Booska{0}Kaydinta:Yar, fufud, ku dul taagan tiir{0}} meel banaan oo dhulka ah oo aan khasaarin
Badbaadada La Wanaajiyey:Kor sare, oo aan dadka iyo duunyadu gaadhi karin. Khatarta kharribaad? Hoose
Waara:Naqshad xiran ayaa ilaalinaysa saliidda. Cimriga? Inta badan 30-60 sano.
Rakibaadda Fudud:Iftiin ku filan hal tiir. Degdeg in loo fuulo
Laakiin ma wada qummana.
Soo-gaadhista DeegaankaDabaysha, roobka, fuulista xayawaanka...dhammaan waxay keeni karaan dhaawac.
Caqabadaha Dayactirka: Haddii ay wax jabaan, waxaad u baahan tahay inaad halkaas ka shaqeyso. Macquul maaha-laakin kharashaadku kor buu u kacaa.

Hot Tags: Transformer on tiirka, saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
15 kVA Tiirka Ku rakiban Beddelka-24.94/0.12*0.24 kV...
100 kVA Transformer tiir Ku rakiban-13.8/0.24 kV|Guy...
167 kVA Korontada Cirifka -13.8 / 0.347 kV|Kanada 2025
50 kVA Transformer Dusha Korontada-7.97/0.12/0.24 kV...
75 kVA Tiirka Ku Rakiban Beddelka-7.97/0.12/0.24 kV|...
75 kVA Utility Transformer-24.94/0.12 kV|Kanada 2025
U dir sooji