15 kVA Tiirka Ku rakiban Beddelka-24.94/0.12*0.24 kV|Kanada 2024
Awoodda: 15kVA
Voltage: 24.94/0.24kV
Muuqaalka: oo leh OCTC

Meesha injineerinka sare uu la kulmo waxqabadka la isku halayn karo-hal- tiirka wejiga{2}}ku rakiban taransfoorayaasha.
01 Guud
1.1 Asalkii Mashruuca
15 KVA hal weji hal tiir ku rakiban transformer waxaa la geeyey Kanada 2024. Awoodda la qiimeeyay ee tiirka ku rakiban transformer waa 15 KVA oo leh qaboojinta ONAN, tamarta aasaasiga ah waa 24.94 KV, danabka labaad waa 0.12/0.24 KV. Waxaa loo qaabeeyey si waafaqsan heerka CSA C2.2-06.
Waddamada horumaray ee galbeedka iyo Koonfur-bari Aasiya, Waqooyiga iyo Koonfurta Ameerika, tiro badan oo hal - transformers ah ayaa loo istcimaalaa qaybinta transformers. Shabakadda qaybinta tamarta ee la qaybiyey, hal -Transformer-ka weji qaybintu waxa uu leeyahay faa'iidooyin waaweyn, waxa uu yarayn karaa dhererka hoose{3}}xadhka qaybinta korantada, waxa uu yareeyaa luminta khadka, wanaajiya tayada sahayda korontada. Naqshadeynta qaabdhismeedka xudunta u ah gariiradda badbaadinta tamarta sare iyo tamar ayaa la qaatay, transformer-ka waxaa lagu gartaa isticmaalka tiirka ku dhejisan hakinta, cabbir yar, maalgelin kaabayaal yar yar, hoos u dhigaya -radius koronto koronto, waxa uu yarayn karaa khasaaraha khadka in ka badan 60%. Transformer-ku waxa uu qaataa qaab-dhismeed si buuxda u xidhan, awood xad-dhaaf ah oo xooggan, isku halaynta sare ee hawlgalka joogtada ah iyo dayactirka fudud. Waxa ay ku habboon tahay xadhkaha korantada ee miyiga, meelaha buuraleyda fog fog, tuulooyinka kala firidhsan, wax-soo-saarka beeraha, nalka iyo isticmaalka tamarta, waxa kale oo loo isticmaali karaa tamarta{9}}badbaadinta beddelka xadhkaha qaybinta tiirarka ee jidadka tareenada iyo korantada magaalooyinka.
Waxaan hubineynaa in mid kasta oo ka mid ah cutubyada nala keenay uu maray imtixaan adag oo aqbalaad ah. Waxaan bixinaa hal{1} adeeg xirmo laga bilaabo la talinta, xigashada, soo saarista, rakibida, hawlgelinta, tababarka ilaa adeegyada iibka kadib, alaabadayadu hadda waxay ka shaqeeyaan in ka badan 50 degmo oo aduunka ah. Waxaan hiigsaneynaa inaan noqono alaab-qeybiyahaaga ugu kalsoonida badan iyo sidoo kale lamaanahaaga ugu fiican ganacsiga!
1.2 Tilmaamaha Farsamada
15 KVA hal weji tiir ku rakiban tafatirka tafatirka iyo xaashida xogta
|
loo geeyey
Kanada
|
|
Sannadka
2024
|
|
Nooca
Turjumaanka Cirifka leh
|
|
Heerka
CSA C2.2-06
|
|
Awood lagu qiimeeyay
15KVA
|
|
Soo noqnoqoshada
60HZ
|
|
Marxaladda
1
|
|
Polarity
Wax lagu daro
|
|
Nooca qaboojinta
ONAN
|
|
Insulant dareere ah
Saliidda Macdanta
|
|
Korantada aasaasiga ah
24.94KV
|
|
Voltage Secondary
0.12/0.24KV
|
|
Qalabka dabaysha
Aluminium
|
|
Caqabada
1.5%
|
|
Taabo Beddelka
OLTC
|
|
Riixista Range
±2*2.5%
|
|
Agabka
Habaynta caadiga ah
|
|
Hadallo
N/A
|
1.3 Sawirro
15 tiir KVA ah oo ku rakiban jaantuska beddelka sawirka iyo cabbirka.
|
|
|
02 Wax-soo-saarka
2.1 Core
Xudunta birta waxay qabataa habka xudunta qaloocinta fidsan, kaas oo leh waxqabadka korantada sare, xamaasad yar oo hadda ah, hooseeyo maya - lumitaanka rarka, qaylada hoose, cabbirka yar, miisaanka fudud, ilaalinta deegaanka iyo badbaadinta tamarta, wax soo saarka asaasiga ah ee dabacsan, isku halaynta tayada sare leh, cabbirka muuqaalka yar iyo faa'iidooyinka kale, waxay buuxin kartaa shuruudaha macaamiisha cabbir kasta.

2.2 Dabaylaha

Transformer-ka bireedku waa nooc cusub oo taransfooriyaha qalalan marka la barbar dhigo transformer-ka dhaqameedka, oo hooseeya - dabaysha korantada kuma dhaawacdo leexashada silig naxaas ah oo siman, laakiin waxa lagu duuduubay ballac xaashi bireed aluminium ah oo u dhaw dhererka harqoodka sare iyo hoose. Beddelka bireedku wuxuu leeyahay faa'iidooyin badan, sida miisaanka fudud, walxo yar, xoog gaaban oo gaaban - iska caabin wareeg ah iyo waxtarka wax soo saarka ballaaran ee sarreeya.
2.3 Haanta
Shirkadeena waxay u isticmaashaa birta aan tayada lahayn - oo ah alaabta ceeriin ee soo saarista haamaha shidaalka, waxayna isticmaashaa mishiinada haydarooliga ama qalabka kale ee samaynta si ay u laaloosho, u jarto oo ugu cadaadiso saxanka birta qaabka la rabo ee haanta shidaalka. Dabada qaybaha oo samee alxanka gaashaanka gaaska ama hababka alxanka kale si loo hubiyo cidhiidhiga iyo xoogga qaabdhismeedka taangiga. Dhammaan shaabadihii waxa lagu xidhay xadka ugu dambeeya; Qaybaha birta ah ee gudaha iyo dibadda santuuqa ayaa lagu soo koobay si ay timaha uga saaraan, iyo tolitaanka alxanka iyo shaabadda ayaa la tijaabiyaa saddex jeer (fluorescence, cadaadis togan, tijaabada daadinta cadaadiska xun); Rinjiga waxaa loo sameeyay si waafaqsan heerka caadiga ah ee ka-hortagga{3} shuruudaha miridhku.

2.4 Kulanka ugu dambeeya

Habka isku dhafka ah ee hal -
1. Ku rakib xudunta birta kursiga xudunta u ah birta. Waa in la ogaadaa in aysan jirin geeso fiiqan oo ku yaal kursiga si looga fogaado in la gooyo walxaha dahaarka.
2. Ku rakib walxaha dahaarka ee xudunta birta. Shaqada walxaha dahaarka ayaa ah in la go'doomiyo gariiradda gelinta ee gariiradda wax soo saarka iyo ka hortagga wareegyada gaaban ee u dhexeeya dabaylaha.
3. Ku duub gariiradda ku wareegsan alaabta dahaadhka ah. Fiiro gaar ah u yeelo isku xigxiga dabaysha, taas oo ah in lagu fuliyaa si waafaqsan shuruudaha naqshadeynta. Isla mar ahaantaana, sidoo kale waa lagama maarmaan in fiiro gaar ah loo yeesho in dabaysha gariiradda ay sax tahay, haddii kale waxay saameyn doontaa waxtarka shaqada ee transformer-ka.
4. Iskudubbaridi guddiga terminalka. Boodhka terminalku wuxuu noqon karaa boosteejo siligga ah ama terminal. Dooro terminaalka ku salaysan xaaladda dhabta ah. Intaa waxaa dheer, waa lagama maarmaan in fiiro gaar ah loo yeesho xajmiga boostada siliga ama terminalka, si loo waafajiyo gariiradda.
5. Ku xidh gariiradda sabuuradda terminalka. Markaad isku xirayso gariiradaha iyo looxyada terminaalka, isticmaal agabka dahaarka saxda ah si aad u hubiso isku xirnaanta la isku halayn karo oo degan.
6. Isku duwi qolofka. Shaqada ugu weyn ee guryuhu waa in la ilaaliyo gariiradda oo si badbaado leh loo go'doomiyo wax-soo-saarka iyo soo-saarka. Marka la ururinayo, waxaa lagama maarmaan ah in la fiirsado xajmiga iyo walxaha qolofka, iyo sidoo kale in la tixgeliyo shuruudaha kuleylka iyo ilaalinta.
03 Tijaabinta
Halbeeg -Transformers-ka wejiga ah badanaa waxay u baahan yihiin inay maraan imtixaanada soo socda:
Tijaabada dahaarka: oo ay ku jiraan tijaabada caabbinta dahaadhka, tijaabada lumitaanka dielectric iyo tijaabada dheecaanka qayb ahaan si loo hubiyo daacadnimada nidaamka dahaarka.
Tijaabada Voltage: Codso xoogaa danab ah oo u dhexeeya hogaanka danab sare iyo hogaanka danab yar si aad u tijaabiso in dahaarka transformerku u adkeysan karo danab sare.
Tijaabada iska caabinta: Tijaabi iska caabinta dabaysha iyo nidaamka dhulka si aad u hubiso inay buuxisay shuruudaha naqshadaynta.
Maya-Tijaabada rarka: Tijaabi waxqabadka korantada ee taransfooriyaha hoos mara- xaaladaha rarka, oo ay ku jiraan maya{2}}load lumin iyo maya{3}}load current.
Tijaabada culeyska: tijaabi waxqabadka taransfooriyaha ee culeyska la qiimeeyay si aad u hubiso inuu u shaqeyn karo si sugan oo la isku halleyn karo.
Tijaabada kor u kaca heerkulka: marka la eego xaaladaha culeyska la qiimeeyay, tijaabi heerkulka kor u kaca ee taransfooriyaha si aad u hubiso in aysan waxyeelo u geysan kulaylka.
Tijaabada culeyska xad dhaafka ah: Tijaabi awoodda culeyska koronto-dhaliyaha si aad u hubiso in uusan waxyeelo soo gaarin haddii uu jiro culeys xad dhaaf ah oo ku meel gaar ah.
Tijaabada wareegga gaaban: Tijaabi awoodda wareegga gaaban ee beddelka si aad u hubiso in aanay waxyeello u geysan xaaladda wareegga gaaban.


04 Baakaynta iyo dhoofinta


05 Goobta iyo Kooban
Waad ku mahadsan tahay xiisahaada - tiirka wejiga -ku rakiban transformerka! Faa'iidooyinka waxtarka sare leh, isku halaynta, iyo badbaadinta tamarta, alaabtan ayaa si weyn loogu isticmaalaa nidaamyada qaybinta awoodda, buuxinta baahida awoodda ee xaaladaha kala duwan. Waxaa naga go'an inaan bixino{3}}alaabooyin iyo adeegyo tayo sare leh si aan u hubinno badbaadada iyo xasiloonida hawlgalka nidaamyada tamartaada. Waxaan rajeyneynaa inaan kula shaqeyno si aan u sii wadno horumarinta warshadaha korontada!

Hot Tags: 15 kva tiir ku rakiban transformer, saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
50 kVA Tiirka Ku Rakiban Transformers-34.5/0.48 kV|K...
75 kVA Transformer ee Xadhkaha Korontada-12.4*24.94/...
167 kVA Korontada Cirifka -13.8 / 0.347 kV|Kanada 2025
167 kVA Tiirka Ku Rakiban Badal Qaybinta-24.94/0.12/...
50 kVA Transformer Dusha Korontada-7.97/0.12/0.24 kV...
50 kVA Transformer Utility Tiirka-13.8/0.24 kV|Guyan...
U dir sooji