100 kVA Cirifka Buurta Beddelka-24.94 / 0.347 kV|Kanada 2024

100 kVA Cirifka Buurta Beddelka-24.94 / 0.347 kV|Kanada 2024

Dalka: Kanada 2025
Awoodda: 100 kVA
Voltage: 24.94GrdY/14.4-0.347 kV
Feature: oo leh IFD
U dir sooji

 

 

100 kVA pole mount transformer

Sawirka ugu Yar, Kalsoonida Ugu Badan - Beddelayaasha Tirka Ku Xidhan ee Bixinta Awood Fiican.

 

 

01 Guud

1.1 Sharaxaada Mashruuca

100 kVA hal waji oo tiir ku rakiban transformer ayaa la geeyey Kanada 2025. Awoodda la qiimeeyey ee transformerku waa 100 kVA oo leh ONAN qaboojin. Korantada aasaasiga ah waa 24.94GrdY / 14.4 kV oo leh ± 2 * 2.5% cabirka garaaca (NLTC), danab labaad waa 0.347 kV, waxay sameeyeen koox vector ah Ii6.

Tiirkan 100 kVA{1}ku rakiban Transformer waxa loogu habeeyey si uu sareeyo{2}} qaybinta awooda wax qabad ee shabakadaha korantada, isku darka isku halaynta, badbaadada, iyo la qabsiga codsiyada miyi iyo magaalaba. Naqshadeynta si ay ugu adkeysato baahida bay'ada iyo xaaladaha hawlgalka, waxay ku daraysaa ilaalinta muhiimka ah iyo qaybo shaqaynaysa si loo hubiyo adeeg aan kala go' lahayn iyo nolol hawleedka la dheereeyey.

Astaamaha muhiimka ah waxaa ka mid ah qalabka gargaarka cadaadiska si uu si badbaado leh u soo saaro cadaadiska xad-dhaafka ah haddii ay jiraan cillado gudaha ah, taas oo yaraynaysa khatarta dillaaca taangiga. Taageerada isku-dhafan ee xirxirayaasha waxay siisaa kor-u-qaad sugan oo loogu talagalay xirayaasha qalliinka, taasoo kor u qaadeysa ilaalinta ka-hortagga hillaaca iyo ku-meel-gaadhka korantada. Si loo ogaado cilada horumarsan, taransfooriyuhu waxa uu ku qalabaysan yahay IFD, kaas oo awood u siinaya in goor hore la ogaado cilladaha aan caadiga ahayn si looga hortago guul-darrooyinka masiibada ah. Intaa waxa dheer, off{3}} beddelka tuubada wareeggu waxa ay ogolanaysaa hagaajinta korantada dabacsan (marka la tamarsiiyo), iyada oo la hubinayo waxqabadka ugu fican ee xaaladaha culayska kala duwan.

Waxaa loo dhisay adkeysiga iyo fududaynta dayactirka, transformer-kani waxa uu bixiyaa qaybinta tamar wax ku ool ah iyada oo mudnaanta la siinayo badbaadada iyo adkeysiga hawlgalka, taas oo ka dhigaysa xal ku habboon kaabayaasha tamarta casriga ah.

 

 

 

1.2 Tilmaamaha Farsamada

167 kVA tiirka ku rakiban qalabka beddelka nooca iyo xaashida xogta

loo geeyey
Kanada
Sannadka
2025
Nooca
Transformer ku rakiban tiirarka
Heerka
CSA C2.2-06
Awood lagu qiimeeyay
100 kVA
Soo noqnoqoshada
60HZ
Marxaladda
1
Polarity
Wax lagu daro
Nooca qaboojinta
ONAN
Korantada aasaasiga ah
24.94GrdY/14.4 kV
Voltage Secondary
0.347 kV
Qalabka dabaysha
Aluminium
barokaca xagal
II6
Caqabada
3%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
0.195 kW
Load Lumista
1.52 kW
Agabka
Habaynta caadiga ah

 

 

1.3 Sawirro

167 kVA tiirka ku rakiban jaantuska beddelka sawirka iyo cabbirka.

100 kVA pole mount transformer drawing 100 kVA pole mount transformer nameplate

 

 

02 Wax-soo-saarka

2.1 Core

Xarigga birta silikoonku si joogto ah ayuu u dhaawacmaa iyadoo la adeegsanayo mishiino sax ah, taasoo keentay isku-xidhka - xudunta xorta ah ee leh dariiqa birlabeedka labbiska ah, yaraynta luminta qul-qulka iyo buuqa. Naqshadaynta bilaa xadka ah waxay yaraynaysaa magnetostriction{2}} gariir keenay, taasoo keentay 5-10 dB heerar sanqadh hoose marka loo eego koofiyadaha la daboolay. Jidka magnetic-symmetrical wuxuu kor u qaadaa iska caabinta eexda DC, taasoo ka dhigaysa mid ku habboon shabakadaha qaybinta ee leh isbedbeddelka korantada ee muhiimka ah. Waxtarka booska sare ee xudunta nabarrada waxay ku habboon tahay shuruudaha cabbirka is haysta ee tiirka{7}ku dhejinta transformers, ku habboon labada qolofka-nooca iyo habaynta dabaysha nooca xudunta u ah.

100 kva pole mount transformer silicon steel core

 

2.2 Dabaylaha

100 kVA pole mount transformer winding

Tiirka -Transformers-yada rakiban waxa ay qaataan foil aluminium ah oo la hagaajiyay LV + naxaasta silig HV naqshadaynta: Dhanka LV waxa ay isticmaashaa foornada aluminiumka ah ee dhaawacan (0.2–1.0mm) si ay u qaboojiso wanaagsan, hufnaanta kharashka, iyo iska caabinta wareegga gaaban, halka dhinaca HV ay ka shaqaynayso dabaylaha nabarka lakabka ah ee dabaylaha kor u kaca iyo qiimaynta korantada 2. Caqabadaha sabuuradaha dahaadhka ah iyo impregnation-ka faakuumka waxay kor u qaadaan awoodda dielectric. Dusha sare ee weyn ee foilku waxay wanaajisaa daadinta kulaylka, iyo cufnaanta sare ee naxaasta waxay hubisaa isku-duubnaanta. Xalkan isku-dhafan waxa uu dheellitirayaa dhaqaalaha (Al) iyo isku halaynta (Cu), isaga oo yareynaya khasaaraha rarka 15-25%, taas oo ka dhigaysa mid ku habboon shabakadaha qaybinta.

 

2.3 Haanta

Alaabtayadu waxay u hoggaansamaan kala-soocidda iska caabbinta daxalka C4. Kobcinta farsamada ee soo socota waxay hubinaysaa waxqabadka sare:
1- Xoojinta Xakamaynta Habraaca
Hababka daawaynta ee la wanaajiyey ee dusha sare ayaa la qaatay, iyadoo si adag loo nadiifinayo iyo hababka daaweynta kiimikaad si gebi ahaanba meesha looga saaro wasakhaynta substrate iyadoo la dammaanad qaadayo in si buuxda loogu hoggaansamo qeexida dhumucda dahaarka.
2- Hagaajinta Dhismaha
Full- tignoolajiyada toleynta tolitaanka waxaa lagu dabaqaa alxanka muhiimka ah, si wax ku ool ah u xannibaya dhexgalka qoyaanka ee qaybaha isbeddelka gudaha oo si weyn u wanaajinaya isku halaynta muddada dheer{1}

C4 corrosion resistance oil tank of pole transformer

 

2.4 Kulanka ugu dambeeya

100 kva pole mount transformer assembly

1. Rakibaadda Dabaysha:Ku rux -voltajka sare iyo kan hoose- dabaylaha korantada dul saar xudunta la dahaadhay, hubinta isku xidhka dahaadhka saxda ah iyo hagaajinta farsamada ee sugan.
2. Isku xirka Korontada:Isku xidhka dabaysha waxay u horseedaa beddelka tuubada, baadiyaha, iyo qaybaha kale, ka dibna xaqiiji caabbinta xidhiidhka.
3. Xudunta - Qalajinta gariiradda:Geli qaybta firfircoonida leh (core + windings) foornada qallajisa si aad u nadiifisid qoyaanka una hubiso hufnaanta dahaarka.
4. Meelaynta Haamaha:Ku rid qaybta firfircoon ee engegan taangiga oo ku xidh boolal-saldhig.
5. Rakibaadda Agabka:Buur kaymaha, IFD, waalka gargaarka cadaadiska, iyo qalabyada kale, oo xidhaya dhammaan kala-goysyada.
6. Buuxinta & Xidhida Saliidda:Vacuum-ku buuxi saliidda dahaadhka ilaa heerka la cayimay, ka dibna tijaabi tayada saliidda iyo adkaynta haanta ka dib markaad dejiso.

 

 

03 Tijaabinta

Maya

Shayga Tijaabada

Unug

Qiimaha Ogolaanshaha

Qiimaha la qiyaasay

Gabagabo

1

Cabbiraadaha iska caabinta

/

/

/

Gudub

2

Imtixaanada saamiga

/

Weecashada saamiga danab ee taabashada maamulaha: In ka yar ama la mid ah 0.5%

Astaanta isku xirka: II6

-0.04

Gudub

3

Tijaabada polarity

/

Wax lagu daro

Wax lagu daro

Gudub

4

Maya- khasaarooyinka rarida iyo xamaasadda hadda

%

I0 :: Bixi qiimaha la qiyaasay (100%)

0.17

Gudub

kW

P0: bixi qiimaha la qiyaasay (100%)

0.161

%

I0 :: Bixi qiimaha la qiyaasay (105%)

0.33

kW

P0: bixi qiimaha la qiyaasay (105%)

0.204

/

Dulqaadka wax qabad la'aan waa +15%

/

5

Khasaaraha culeyska, korantada impedance, wadarta khasaaraha iyo hufnaanta

/

t:85 darajo

dulqaadka impedance waa ± 7.5%

dulqaadka wadarta rarka luminta waa +8%

/

Gudub

%

Z%: qiimaha la qiyaasay

3.16

kW

Pk: qiimaha la qiyaasay

1.377

kW

Pt: qiimaha la qiyaasay

1.538

%

Waxtarka aan ka yarayn 98.94%

99.07

6

Tijaabada Korantada ee La dabaqay

/

LV: 10kV 60s

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

7

Tijaabada adkaysiga korantada ee keentay

/

Danab la dabaqay (KV):2Ur

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

Muddada:48

Inta jeer (HZ): 150

8

Cabbirka iska caabinta dahaarka

LV-HV ilaa Ground

43.3

Gudub

9

Tijaabada daadinta

/

Cadaadiska la dabaqay: 20kPA

Wax daadsan iyo maya

Waxyeello

Gudub

Muddada:12h

10

Tijaabada Saliida

kV

Xoogga Dielectric

57.4

Gudub

mg/kg

Nuxurka qoyaanka

9.3

%

Qodobka Burburinta

0.00254

mg/kg

Falanqaynta Furan

0.03

/

Falanqaynta Chromatography ee Gaaska

/

 

100 kVA pole mount transformer testing
100 kVA single pole mount transformer tesing

 

 

04 Baakaynta iyo dhoofinta

4.1 Xirxirida

Tiirka kaliya ee --Transformer-ka lagu rakibay waxa lagu guray saxan alwaax ka-hortag ah, oo gudaha lagu sugay bilal iyo shoog{3}oo nuugaya suufyada caagga ah, iyo qaybaha jilicsan waxaa lagu ilaaliyaa xumbo. Sanduuqa waxa lagu duuduubay UV{5}maro aan roobka adkaysan karin, oo lagu xidhxidhay xadhkaha nayloon, tolaguna waa la xidhay. Godadka hawo-qaadista ayaa lagu daraa dusha sare. Baakadu waxay ka kooban tahay calaamadaha kor u qaadista, qallajiyeyaasha, iyo kiish dukumeenti aan biyuhu lahayn, hubinta ku habboonaanta gaadiidka badda iyo dibadda.

100 kVA pole mount transformer packing

 

4.2 dhoofinta

100 kVA pole mount transformer delivery

Marka loo eego shuruudaha CIF, iibiyuhu waxa uu ku raray tiirka tiirka-wuxuu ku dhejiyaa beddelaadaha ilaa Montreal Port, Canada, kaas oo daboolaya kharashka, caymiska badda, iyo xamuulka. Transformers si badbaado leh ayaa loo jeexjeexay ( alwaax/ bir ah) waxaana lagu raraa xamuulka badweynta (koonteenar ama jajab), oo leh dhammaan caymiska Khatarta. Marka uu yimaado, iibsaduhu waxa uu gacanta ku hayaa fasaxa kastamka iyo keenista gaadhiga u dambeeya. Dukumeentiyada muhiimka ah waxaa ka mid ah B/L, qaansheeg ganacsi, liiska baakadaha, iyo shahaadada caymiska. Caqabadaha waxaa ka mid ah ilaalinta cimilada jiilaalka iyo dib u dhaca kastamka.

 

 

05 Goobta iyo Kooban

Tiirarka -Transformers-ku rakiban waxa ay bixiyaan isafgarad, kharash{1}} wax ku ool ah, oo xal la isku halayn karo oo loogu talagalay qaybinta awooda sare ee shabakadaha magaalooyinka iyo miyiga. Naqshadeynta adkeysiga iyo rakibidda sahlan, waxay xaqiijiyaan isbeddel wax ku ool ah oo leh dayactirka ugu yar. Haddi ay ahaan lahayd tas-hiilaadka, codsiyada warshadaha, ama is dhexgalka tamarta la cusboonaysiin karo, transformers-yadayadu waxay la kulmaan heerarka caalamiga ah (IEEE, IEC, CSA) waxaana loo dhisay bay'ad adag. Nala soo xidhiidh maanta si aad u hesho xalalka la habeeyey ee ku habboon shuruudahaaga shabakad.

100 kVA single pole mount transformer

 