50 KVA Tiirka Ku Rakiban Tamashlaha 3 Wajiga-2.4/0.6 KV|Kanada 2025
Awoodda: 50kVA
Voltage: 2.4/0.6 kV
Sifada: leh IFD iyo daba-galka- lidka ku ah

Fududeyso Shabakaddaada Qeex beddelka tiirka ku rakiban wejiga Keliya.
01 Guud
1.1 Sharaxaada Mashruuca
50 kVA hal waji oo tiir ku rakiban transformer ayaa la geeyey Kanada 2025. Awoodda la qiimeeyay ee transformerku waa 50 kVA oo leh ONAN qaboojin. Korontada sare waa 2.4 kV, danab hooseeya waa 0.6 kV, waxay sameeyeen koox vector ah II6.
Loogu talagalay adkeysiga dhammaan codsiyada muhiimka ah-ay ku jiraan xaafadaha magaalada ee cufan, quudiyeyaal beeralayda, iyo sahayda ganacsiga muhiimka ah{1}Transformer-kani waxa uu isku daraa Cilada Gudaha (IFD) iyo Anti-Dahaadhka daba-galka ah. IFD waxay bixisaa sirdoon saadaaliya si ay dayactirka uga bedesho falcelis una bedesho firfircooni, yaraynta wakhtiyada maqnaanshaha, halka Kahortagga{4}} Dabagalka guryuhu uu hubinayo waxqabadka aan leexleexanayn ee meelaha wasakhaysan ama sare - qoyaanka. Farsamadan laba-geesoodka ah waxay si toos ah hoos ugu dhigaysaa wadarta qiimaha lahaanshaha ee yutiilitida waxayna xoojisaa isku halaynta awooda bulshada.
1.2 Tilmaamaha Farsamada
167 kVA tiirka ku rakiban qalabka beddelka nooca iyo xaashida xogta
|
loo geeyey
Kanada
|
|
Sannadka
2025
|
|
Nooca
Transformer ku rakiban tiirarka
|
|
Heerka
CSA C2.2-06
|
|
Awood lagu qiimeeyay
50 kVA
|
|
Soo noqnoqoshada
60HZ
|
|
Marxaladda
1
|
|
Polarity
Wax lagu daro
|
|
Nooca qaboojinta
ONAN
|
|
Korantada aasaasiga ah
2.4 kV
|
|
Voltage Secondary
0.6 kV
|
|
Qalabka dabaysha
aluminium
|
|
Kooxda Vector
II6
|
|
Caqabada
2.1%(±10%)
|
|
Taabo Beddelka
N/A
|
|
Wax Xamuul ah ma jiro
0.044 kW
|
|
Load Lumista
0.7 kW
|
1.3 Sawirro
50 kVA tiir ku rakiban jaantuska beddelka sawirka iyo cabbirka.
![]() |
![]() |
02 Wax-soo-saarka
2.1 Core

Transformer-ku waxa uu leeyahay xudunta boogta ee ka samaysan hadhuudh{0}} bir silikoon ku jihaysan. Naqshaddan aan kala go'a lahayn waxay yaraynaysaa khasaaraha asaasiga ah iyo magnetizing hadda, kor u qaadaysa waxtarka. Waxa kale oo ay yaraynaysaa qaylada shaqada waxayna kor u qaadaysaa cimriga farsamada ee nolosha adeeg dheer.
2.2 Dabaylaha
Transformer-kani waxa uu isticmaalaa dabaylaha aluminium horumarsan, oo leh dabaylaha hoose -voltage-ka loo sameeyay sidii foorno lakab ah iyo dabaylaha sare{1}} sida gariiradda helical. Faylkan -iyo -isku darka siliggu wuxuu xaqiijiyaa xoog makaanik aad u wanaagsan iyo daadinta kulaylka hufan. Dhammaan -Dhismaha aluminiumku waxa uu bixiyaa miisaan fudud iyo kharash{7}} xal wax ku ool ah iyada oo aan waxba loo dhimayn waxqabadka.

2.3 Haanta

Waxaa loo dhisay cimriga ugu dambeeya, transformer-kan waxa uu leeyahay haan ka samaysan bir aan-xawaag lahayn. Doorashada alaabtan waxay bixisaa qaabdhismeed heer sare ah iyo iska caabin cimilada iyo daxalka kiimikada. Dhismaha aan xidhnayn, alxanka leh ayaa dammaanad qaadaysa daadinta{2}} hawlgalka caddaynta iyo waxqabadka la isku halayn karo ee codsiyada dibadda ee ugu baahida badan.
2.4 Kulanka ugu dambeeya
Isku dhafka ugu dambeeya ee hal - tirka wejiga{1}}ku rakiban transformer-ka ayaa isku daraa xudunta -iyo- unugga gariiradda, si taxadar leh horey -lagu tijaabiyay, galka taangiga birta ah ee aan dabada lahayn kaas oo ka dibna ay ka buuxaan dareere dielectric la safeeyey. Nidaamkan muhiimka ah waxaa lagu sameeyaa qallajin adag oo faakuum ah si loo baabi'iyo qoyaanka, hubinta daacadnimada ugu fiican. Qaybaha muhiimka ah ee dibadda -bushings, IFD iyo anti-raadinta- ayaa markaa si amaan ah loo rakibay, oo ku dhamaanaysa unug si buuxda u shaabadaysan, adag, oo la isku halayn karo oo diyaar u ah dhawr sano oo adeeg ah.

03 Tijaabinta
Midka -Tiirka wejiga{1}ku rakiban taransfooriyaha (qaabka: 50kVA-2.4/0.6kV) ee SCOTECH wuxuu raacay heerarka CSA C2.2-06(R2022) iyo CSA C802.1-13(R2022). Tijaabooyinka caadiga ah waxaa ka mid ahaa cabbirka iska caabbinta dabaysha (HV: 0.5552Ω, LV: 36.26mΩ at 31 degree), imtixaanka saamiga ( weecasho: -0.02% In ka yar ama la mid ah 0.5%, kooxda vector: Ii6), tijaabada polarity (wax ku daray, u hoggaansan), imtaxaan-load ah 0 gudahood: {8}% gudahood: {8} 0.95%), imtixaanka load (lumin: 602W at 85 degree, danab impedance: 2.15% gudahood ± 10% dulqaadka, khasaaraha guud: 642W, hufnaan: 99,30% ka weyn ama la mid ah 99.20%), codsatay imtixaanka danab (LV: 10kV, koronto la dulmay 2) 60sk 150Hz ee 48s, burbur la'aan), cabbirka caabbinta caabbinta (LV-HV ilaa dhulka: 89.9GΩ), 20kPa tijaabada daadinta cadaadiska (12h, wax daadinta / qallafsanaanta), iyo tijaabada saliidda (xoogga tamarta: 57.4kV, qoyaan: 9.4mg / kg, iwm.).
|
Maya |
Shayga Tijaabada |
Unug |
Ogolaanshaha Qiimaha |
Qiimaha la qiyaasay |
Gabagabo |
|
1 |
Cabbiraadaha iska caabinta |
/ |
/ |
/ |
Gudub |
|
2 |
Imtixaanada saamiga |
/ |
Weecashada saamiga danab ee taabashada maamulaha: In ka yar ama la mid ah 0.5% Astaanta isku xirka: II6 |
-0.02 |
Gudub |
|
3 |
Tijaabada polarity |
/ |
Wax lagu daro |
Wax lagu daro |
Gudub |
|
4 |
Maya- khasaarooyinka rarida iyo xamaasadda hadda |
% |
I0 :: bixiyaan qiime la qiyaasay |
0.95 |
Gudub |
|
kW |
P0: bixi qiimaha la qiyaasay |
0.040 |
|||
|
/ |
Dulqaadka wax qabad la'aan waa +15% |
/ |
|||
|
5 |
Load khasaaraha , danab impedance, khasaaraha guud iyo hufnaan |
/ |
t:85 darajo dulqaadka impedance waa ± 10% dulqaadka wadarta rarka luminta waa +8% |
/ |
Gudub |
|
% |
Z%: qiimaha la qiyaasay |
2.15 |
|||
|
kW |
Pk: qiimaha la qiyaasay |
0.602 |
|||
|
kW |
Pt: qiimaha la qiyaasay |
0.642 |
|||
|
% |
Waxtarka aan ka yarayn 99.20% |
99.30 |
|||
|
6 |
Tijaabada Korantada ee La dabaqay |
/ |
LV: 10kV 60s |
Ma jiro burbur ku yimaada tamarta tijaabada ah |
Gudub |
|
7 |
Tijaabada adkaysiga korantada ee keentay |
/ |
Danab la dabaqay (KV): 1.2 |
Ma jiro burbur ku yimaada tamarta tijaabada ah |
Gudub |
|
Muddada:48 |
|||||
|
Inta jeer (HZ): 150 |
|||||
|
8 |
Cabbirka iska caabinta dahaarka |
GΩ |
LV-HV ilaa Ground |
89.9 |
Gudub |
|
9 |
Tijaabada daadinta |
/ |
Cadaadiska la dabaqay: 20kPA |
Wax daadsan iyo maya Waxyeello |
Gudub |
|
Muddada: 12h |
|||||
|
10 |
Tijaabada Saliida |
kV |
Xoogga Dielectric |
57.4 |
Gudub |
|
mg/kg |
Nuxurka qoyaanka |
9.4 |
|||
|
% |
Qodobka Burburinta |
0.00251 |
|||
|
mg/kg |
Falanqaynta Furan |
0.03 |
|||
|
/ |
Falanqaynta Chromatography ee Gaaska |
/ |


04 Baakaynta iyo dhoofinta
4.1 Xirxirida

Tiirka kaliya ee - wejiga - ku rakiban transformer-ka waxa lagu baakadeeyay kiis alwaax adag ah oo ka samaysan alwaax. Marka hore, transformer-ka waxaa lagu duuduubay baco si looga ilaaliyo qoyaanka iyo boodhka. Kiis alwaax ah ayaa lagu xoojiyay geeso bir ah si kor loogu qaado xasilloonida qaabdhismeedka inta lagu jiro gaadiidka, waxaana lagu calaamadeeyay calaamadaha maaraynta lagama maarmaanka ah (sida tilmaamayaasha kor u qaadista, calaamadaha dib-u-warshadaynta) iyo sumadaha macluumaadka alaabta. Waxaa intaa dheer, kiisku wuxuu ku dhejiyaa alwaax alwaax ah, kaas oo u oggolaanaya in si sahlan loo raro, loo dejiyo, iyo gaadiidka iyada oo loo marayo fargeeto ama jaakadaha palette.
4.2 dhoofinta
Gaadiidka hoos yimaada CIF Montreal, hal - tiirka wejiga - ku rakiban transformers waxaa lagu raraa badda. Iibiyuhu wuxuu mas'uul ka yahay inuu qandaraas la galo sideha, bixinta kharashka xamuulka ee Port Montreal, iyo helitaanka caymiska badda. Transformers-yada waxaa lagu raray si waafaqsan shuruucda maraakiibta badda, iyadoo si taxadar leh loo maareeyo inta lagu jiro raritaanka markabka iyo gaadiidka si loo hubiyo inay ku yimaadaan Dekedda Montreal xaalad wanaagsan.

05 Goobta iyo Kooban
Marka la soo koobo, tiirkeena hal{0}}wajiga{1}ku dhejiyay taransfooriyaha waxa uu ka dhigan yahay isku dhafka ugu wanagsan ee hal abuurnimo, adkeysi, iyo hufnaan. Iyada oo leh astaamo horumarsan sida xudunta nabarka ee khasaaraha hoos u dhaca, daxalka{3}} haanta birta ah ee adkaysiga u leh, iyo bireed aluminium ah oo la isku halayn karo{4}}naqshadda dhaawaca, waxa loo habeeyey si loo bixiyo waxqabad heersare ah iyo wadarta qiimaha lahaanshaha hoose. Transformerkani maaha qayb kaliya balse waa muddo dheer - hantida la isku halayn karo si loo casriyeeyo kaabayaasha shabakadaada, hubinta badbaado iyo xasillooni gaarsiinta bulshooyinka sanadaha soo socda.

Hot Tags: tiirka ku rakiban transformer 3 wejiga, saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
167 kVA Cooper Pad Ku rakiban Beddelka-13.8/0.24 kV|...
25 kVA Transformer Light Tiirka-13.8 / 0.24 kV|Guyan...
50 kVA Hal Tiir Ku rakiban Beddelka-13.8/0.347 kV|Ka...
75 kVA Xadhkaha Korontada Transformer-13.8/0.12*0.24...
50 kVA Transformer On Khadka Korontada-7.97/0.277 kV...
50 kVA Transformer Utility Tiirka-13.8/0.24 kV|Guyan...
U dir sooji