50 kVA Hal Tiir Ku rakiban Beddelka-13.8/0.347 kV|Kanada 2025

50 kVA Hal Tiir Ku rakiban Beddelka-13.8/0.347 kV|Kanada 2025

Dalka: Kanada 2025
Awoodda: 50kVA
Voltage: 13.8/0.347kV
Feature: oo leh xire
U dir sooji

 

 

single pole mounted transformer

Ma jirto cabsi laga qabo hillaac, ma jirto koronto go'day-24/7 Ilaalinta Tiirkayaga ku rakiban Beddelka!

 

 

01 Guud

1.1 Sharaxaada Mashruuca

Sannadkii 2025, 50 kVA hal - tiir weji -ku rakiban taransfooraha ayaa la geeyey Kanada si loogu isticmaalo miyi iyo badh{4}}shabakadaha qaybinta magaalooyinka. Goobtu waxay u adeegtaa kooxo yar yar oo la dego iyo beero maxalli ah ama xamuul ganacsi oo ku shaqeeya xariiqa sare ee 13.8kV. Loogu talagalay in lagu xakameeyo baahida ugu sarreysa ee xilliyeed iyo xaaladaha duufaannada ee soo noqnoqda, transformer-ku waxa uu xaqiijiyaa koronto deggan oo hufan xitaa deegaannada adag.

Lagu dhisay heerka CSA C2.2-06, cutubku waxa uu leeyahay qaboojin ONAN, 13.8 kV/0.347 kV ratings, Ii6 vector group, iyo polarity Additive. Waxaa ku jira beddelaha tuubada NLTC oo leh ± 2 × 2.5% kala duwan oo loogu talagalay hagaajinta korantada saxda ah. Iyada oo aluminium dabaysha, 2.3% impedance, iyo 98.35% hufnaan, waxay bixisaa waxqabad xoog leh oo leh khasaare hoose iyo dayactir fudud.

Ku rakiban tiirka qaybinta caadiga ah oo leh goynta aasaasiga ah ee isku dhafan, xirida qalliinka, iyo nidaamka dhulka hoostiisa, transformer-kani waxa uu bixiyaa xal qaybinta awood badbaado leh oo dabacsan. Ku habboon koronto-siinta miyiga, goobaha isgaadhsiinta, iyo culaysyada warshadaha yaryar, waxay isku daraysaa adkeysiga, isku halaynta, iyo xakamaynta korantada aad u fiican ee hal naqshad dibadda ah oo is haysta.

 

 

 

1.2 Tilmaamaha Farsamada

50 kVA tiirka ku rakiban qalabka beddelka nooca iyo xaashida xogta

loo geeyey
Kanada
Sannadka
2025
Nooca
Transformer ku rakiban tiirarka
Heerka
CSA C2.2-06
Awood lagu qiimeeyay
50 kVA
Soo noqnoqoshada
60HZ
Marxaladda
1
Polarity
Wax lagu daro
Nooca qaboojinta
ONAN
Korantada aasaasiga ah
13.8 kV
Voltage Secondary
0.347 kV
Qalabka dabaysha
Aluminium
barokaca xagal
II6
Caqabada
2.3%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
0.135 kW
Load Lumista
0.705 kW

 

 

1.3 Sawirro

50 kVA tiir ku rakiban jaantuska beddelka sawirka iyo cabbirka.

single pole mounted transformer diagram single pole mounted transformer nameplate

 

 

02 Wax-soo-saarka

2.1 Core

Transformer-kani waxa uu leeyahay nakhshad horumarsan oo udub-dhexaad nabar ah, halkaas oo udub dhexaadka uu si joogto ah u nabarro sare -qabow ka bixi kara{1}} xariijimaha birta silikoon duuban si ay u sameeyaan wareeg birlab ah oo xidhxidhan oo aan toos ahayn. Marka la barbar dhigo koofiyadaha dahaadhka ah ee caadiga ah, xudunta boogtu waxay bixisaa khasaare hoose -, qaylada oo yaraada, qaybinta qulqulka lebiska ah, iyo iska caabbinta wareegga gaaban ee la xoojiyey.

advanced wound core design

 

2.2 Dabaylaha

current losses

Transformer-kani waxa uu shaqeeyaa tignoolajiyada horumarsan ee dabaysha: dhinaca hoose -Voltage (LV) waxa ay ka faa'iidaysataa dabaylaha foil si ay u hesho wakhtigan sare{1}}qaadida awooda iyo kala daadinta kulaylka, si wax ku ool ah u yaraynaysa khasaaraha hadda jira; halka dhinaca sare -Voltage (HV) ay qaadanayaan dabaylaha siligga ee saxda ah si loo hubiyo xoogga dahaarka iyo xasilloonida korantada. Naqshadan la isku daray ee "foil{4}} boogta LV + silig - boogta HV " waxay gaartaa waxtarka ugu wanagsan, isafgaradka iyo iska caabinta wareegga gaaban, taasoo ka dhigaysa mid ku habboon dalabka tiirka bannaanka - codsiyada rakiban.

 

2.3 Haanta

Transformer-kani waxa uu shaqeeyaa haanta cylindrical hermetically shaabadaysan oo lagu sameeyay habka qaloocinta saxda ah. Laga sameeyay qabow heersare ah{1} bir duuban, taangiga waxaa qaabeeyay mishiinka duuban ee CNC oo leh hal leys oo saxan oo kaliya{2}} tol dhererka alxanka ah, oo si adag loo eego X{{3}ray iyo tijaabooyinka daadinta. Naqshadaynta cylindrical waxay bixisaa ma aha oo kaliya bilicda is haysta, laakiin sidoo kale xoog farsamo oo gaar ah iyo daadinta kulaylka, oo ay ku jiraan wadooyin hagaya saliida gudaha ee cusub ee qaboojinta dabiiciga ah ee hufan. Iyada oo leh saddex-laab{6}}lakab ka-hortag- daahan daxalka ah (primer + epoxy intermediate + polyurethane topcoat), waxay u adkaysataa bay'ada adag sida buufinta milixda iyo roobka aashitada.

sealed cylindrical tank

 

2.4 Kulanka ugu dambeeya

single pole mounted transformer final assembled

1. Golaha dabaysha:U jiid dabaylaha HV/LV una dul saar xudunta dahaarka leh, adoo hubinaya in si sax ah loo siman yahay iyo nadiifinta dahaarka.
2. Isku xirka Korontada:Isku xidhka dabaysha waxay keenaysaa beddelayaasha tuubada, baadiyaha, iyo qaybaha kale, oo ay ku xigto adkaynta iyo daweynta dahaarka.
3. Xudunta - Qalajinta gariiradda:Geli qaybta firfircoon ee la soo ururiyey foornada qallajisa si aad uga saarto qoyaanka oo kor u qaaddo waxqabadka dahaarka.
4. Rakibaadda Haamaha:Ku rid qaybta firfircoon ee engegan taangiga, ku xafid booska, oo xidh daboolka haanta.
5. Kordhinta Agabka:Ku rakib bushings, xire, valve gargaarka cadaadiska.
6. Buuxinta & Xidhida Saliidda:Vacuum-ku buuxi saliid dahamiya, hubi heerka saliidda iyo xidhidhiyaha ka dib dejinta, oo samee tijaabooyinka ugu dambeeya ee dhamaystirka.

 

 

03 Tijaabinta

Maya

Shayga Tijaabada

Unug

Qiimaha Ogolaanshaha

Qiimaha la qiyaasay

Gabagabo

1

Cabbiraadaha iska caabinta

/

/

/

Gudub

2

Imtixaanada saamiga

/

Weecashada saamiga danab ee taabashada maamulaha: In ka yar ama la mid ah 0.5%

Astaanta isku xirka: II6

0.06~0.10

Gudub

3

Tijaabada polarity

/

Wax lagu daro

Wax lagu daro

Gudub

4

Maya- khasaarooyinka rarida iyo xamaasadda hadda

%

I0 :: Bixi qiimaha la qiyaasay (100%)

0.24

Gudub

kW

P0: bixi qiimaha la qiyaasay (100%)

0.1065

%

I0 :: Bixi qiimaha la qiyaasay (105%)

0.24

kW

P0: bixi qiimaha la qiyaasay (105%)

0.1172

/

Dulqaadka wax qabad la'aan waa +10%

/

5

Khasaaraha culeyska, korantada impedance, wadarta khasaaraha iyo hufnaanta

/

t:85 darajo

dulqaadka impedance waa ± 15%

dulqaadka wadarta rarka luminta waa +6%

/

Gudub

%

Z%: qiimaha la qiyaasay

2.28

kW

Pk: qiimaha la qiyaasay

0.634

kW

Pt: qiimaha la qiyaasay

0.7405

%

Waxtarka aan ka yarayn 98.84%

99.01

6

Tijaabada Korantada ee La dabaqay

/

LV: 10kV 60s

HV: 34kV 60s

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

7

Tijaabada adkaysiga korantada ee keentay

/

Danab la dabaqay (KV):2 Ur

Ma jiro burbur ku yimaada tamarta tijaabada ah

Gudub

Muddada:40

Inta jeer (HZ): 180

8

Cabbirka iska caabinta dahaarka

HV-LV·to·Ground

451

Gudub

LV-HV ilaa Ground

489

HV&LV ilaa Ground

113

9

Tijaabada daadinta

/

Cadaadiska la dabaqay: 20kPA

Wax daadsan iyo maya

Waxyeello

Gudub

Muddada:12h

10

Tijaabada Saliida

kV

Xoogga Dielectric

61.3

Gudub

mg/kg

Nuxurka qoyaanka

10.6

%

Qodobka Burburinta

0.091

mg/kg

Falanqaynta Furan

In ka yar ama la mid ah 0.1

/

Falanqaynta Chromatography ee Gaaska

/

 

single pole mounted transformer test
single pole mounted transformer routine test

 

 

04 Baakaynta iyo dhoofinta

4.1 Xirxirida

Transformer-ku waxa uu ku jiraa sanduuq alwaax ah oo si buuxda u xidhan oo lagu dhisay qoyaan{0}} alwaax aan caddayn, lehna caado -lakabyada xumbo-samaynta iyo ka-hortagga gariirrada si ay u dhaqaajiso cutubka inta lagu jiro safarka. Bannaanka waxa lagu dahaadhay faash aan biyuhu lahayn waxaana lagu xoojiyay xargaha birta ah, ku qalabaysan - lugaha qaadista waajibaadka saaran ee gees kasta. Kahor inta aan la xirin, transformer-ku waxa uu maraa qalajinta faakuumka waxaana ka buuxsamay 0.02MPa nitrogen. Calaamadaha caalamiga ah ee caanka ah ee xarunta cufisjiidadka, "Ka dhig qallayl" iyo "Dhinacan kor u kaca" ayaa la soo bandhigay. shahaado la siiyay heerarka ISTA 3A, baakadu waxay u adkaysanaysaa 2000km gaadiidka waddooyinka iyo xaaladaha xamuulka badda ee caalamiga ah.

enclosed wooden crate

 

4.2 dhoofinta

CIF terms

Transformers-yada waxaa lagu soo rari doonaa shuruudaha CIF (Qiimaha, Caymiska, iyo Xamuulka), iyagoo ka dhoofaya dekedda Ningbo una socda Dekedda Montreal. Shixnadda waxaa lagu rari doonaa iyada oo la marinayo xamuulka badda ee weel lagu shubay, iyadoo leh rar sugan iyo tallaabooyin ilaalin ah (ka-hortagga shoogga, qoyaanka{2}}Caddaynta, iyo ka hortagga-daxalka) si loo hubiyo badqabka dheer{4}} gaadiidka badda. Iibiyuhu wuxuu diyaarin doonaa gaadiidka badda wuxuuna bixin doonaa caymis badeed (Dhammaan Khatarta), oo daboolaya khasaaraha ka iman kara shilalka ama masiibooyinka dabiiciga ah inta lagu jiro safarka. Markay yimaadaan Montreal, iibsaduhu wuxuu mas'uul ka yahay nadiifinta kastamka iyo gaadiidka gudaha ee dheeraadka ah.

 

 

05 Dayactirka tiirarka -Transformers ee rakiban

Ilaalinta tiirka -Transformers-ku rakiban maaha kaliya inaad saxdo liiska hubinta. Waxay ku saabsan tahay hubinta in unug kasta uu u sii shaqeeyo si badbaado leh, hufan, iyo ilaa inta suurtogalka ah. Badbaadada, isku halaynta, iyo joogtaynta - dhamaantood waxay ku xidhan yihiin tafaasiisha yaryar. Mararka qaarkood, tafaasiisha kuwa kale way iloobaan.
(1) Kormeerka Muuqaalka Joogtada ah
Talaabada kowaad had iyo jeer waa tan ugu fudud - kaliya eeg. Iskaanka degdega ahi wuxuu inta badan sheegaa wax ka badan warbixin. Iska hubi inay saliiddu soo daadato, daxalka, ama daloolka. Wasaqda saliidda ayaa laga yaabaa inay soo jeediso shaabad xun; miridhku waxay la macno tahay in taangiga uu si tartiib tartiib ah u luminayo xooggiisa. Hagaajinta kuwan hore -ka hor intaanay u korin dhibaatooyin waaweyn{6}}waxay badbaadisaa wakhtiga iyo qalabka labadaba.
(2) Heerka Saliida iyo Hubinta Tayada
Saliida beddelka waa halbowlaha nolosha. Way qaboojisaa, dahaadhaa, ilaalisaa. Saliid yar? Kaasi waa calan cas. Saliid madoobayd ama daruur leh? Sidoo kale dhib. Waayo-aragnimada Scotech waxay muujinaysaa in hubinta saliidda caadiga ah, xitaa kuwa degdega ah, ay ka hortagaan inta badan kiisaska kulaylka ka hor intaysan waligood bilaabin.
(3) Saliidda Nadiifinta
Hadda, mararka qaarkood kormeerku kuma filna. Saliiddu waxay u ekaan kartaa mid fiican laakiin waxay luminaysaa waqti ka dib - qoyaan, gaas, qaybo yaryar ayaa soo dhex dhuunta. Taasi waa marka sifeyntu soo gasho Wareeg kastaa wuxuu soo celiyaa awoodda saliidda, taasoo kordhinaysa cimriga beddelka.
(4) Xidhidhiyeyaasha
Boolasha dabacsan uma muuqdaan kuwo cajiib ah, laakiin waxay keenaan dhibaatooyin dhab ah - boodboodka, meelaha kulaylka ah, guuldarada Xiriir kastaa waa muhiim: baadiyaha, qasabadaha, meelaha dhulka la dhigo. Kooxaha dayactirka Scotech way adkeeyaan, dib u eegaan, oo adkeeyaan mar labaad haddii loo baahdo. Waa shaqo caajis ah, laakiin taasi waa waxa ka dhigaya transformers-ka noolaanshaha sanado badan.
(5) Nadiifinta
Boodhka, xadhkaha shimbiraha, xataa waxay ka tagayaan - waxyaabo yaryar oo xannibaya socodka hawada iyo dabinnada kulaylka. Waqti ka dib, raadiyaha ma neefsan karo. Markaa, nadiifintu maaha wax la isku qurxiyo; waa qayb ka mid ah nidaamka qaboojinta. Transformer nadiif ah ayaa ku shaqeeya qaboojiyaha, waara waqti dheer. Fudud, laakiin

transformer with surge arrester

 