100 KVA Light Transformer-13.8/0.12*0.24 KV|USA 2025
Awoodda: 100 kVA
Voltage: 13.8-0.12/0.24kV
Muuqaal: HV dabaysha: Copper, LV dabaylaha: Aluminium

Lagu kalsoonaan karo, hufan, oo sarreeya{{0}waxqabad - 100 kVA nalka
01 Guud
1.1 Sharaxaada Mashruuca
Transformer-ka 100 kVA nalka waxaa loogu talagalay 13.8 kV saddex -Nidaamyada qaybinta wejiga sare si ay u bixiyaan culeyska sare{3}}, sida meelaha la dego ee cufan ama tas-hiilaadka ganacsi ee yaryar. Waxa kale oo ay u hoggaansantaa IEEE C57.12.20, sifooyin ONAN ku qaboojin leh dahaarka saliidda macdanta, iyo - naxaasta korantada sare iyo hoose- aluminium korantada. Wax soo saarka sare waa 120/240 V. Maya{12}} lumitaanka rarku waa ku dhawaad 0.25 kW, rarka lumitaanka 0.897 kW, taasoo keentay wadarta khasaaraha 1.147 kW, halka hufnaantu ay weli ka sarreyso 98%.
Xakameyntu waa 2.86%, oo la socota transformers qaybinta caadiga ah. Cutubkan waxa kale oo uu ku qalabaysan yahay NLTC maya -loader tuubada rarka, iyo polarity keeda kala goysa iyo kooxda Ii0 vector waxay xaqiijiyaan iswaafajinta wejiga iyo 50 kVA transformer ee isku nidaam ah. Si wada jir ah, labadan transformers ayaa bixiya hufnaan sare, khasaare hoose, iyo la qabsi aad u wanaagsan, iyaga oo keenaya awood ammaan ah oo la isku halayn karo ee shabakadaha qaybinta Waqooyiga Ameerika.
1.2 Tilmaamaha Farsamada
100kVA hal weji tiir ku rakiban tafatirka tafatirka iyo xaashida xogta
|
loo geeyey
USA
|
|
Sannadka
2025
|
|
Nooca
hal weji tiir ku rakiban transformer
|
|
Heerka
IEEE C57.12.20
|
|
Awood lagu qiimeeyay
100 KVA
|
|
Soo noqnoqoshada
60HZ
|
|
Marxaladda
Keli
|
|
Nooca qaboojinta
ONAN
|
|
Insulant dareere ah
Saliidda Macdanta
|
|
Korantada aasaasiga ah
13.8 kV
|
|
Voltage Secondary
0.12 / 0.24 kV
|
|
Kooxda Vector
Ii0
|
|
Polarity
Kala goyn
|
|
Qalabka dabaysha
HV: Copper, LV: Aluminium
|
|
Caqabada
2.86%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
14400,13800,13200,12870,12540
|
|
Wax Xamuul ah ma jiro
0.25 KW
|
|
Load Lumista
0.897 kW
|
|
Agabka
Habaynta caadiga ah
|
1.3 Sawirro
100kVA hal weji suuf ah oo ku rakiban jaantuska jaantuska iyo cabbirka
![]() |
![]() |
02 Wax-soo-saarka
2.1 Core
Xudunta dhaawaca waxay isku daraysaa badbaadinta tamarta iyo waxtarka alaabta. Laga soo dhisay hadhuudh{1} bir silikoon ku jihaysan, waxa ay dhaawacday jihada ugu fiicnayd ee magnetization si loo gaadho socodka qulqulka sareeyo. Xudunta udubdhexaadka ah waxay ilaalisaa sifooyinka birlabeedka deggan ee ka hooseeya heerka saturation. Maaddaama ay kala-goysyadu ka yar yihiin kuwa isku xidhan, waxa ay si weyn u dhimi kartaa qallooca, maya - khasaaraha rarka, iyo dhawaaqa dhawaaqa.
2.2 Dabaylaha
Dabaysha HV waxa loogu talagalay lakabyo xoog leh iyadoo la isticmaalayo -kaari naxaas nadiif ah oo sarreeya, oo lagu dahaadhay dahaarka dhaldhalaalka si loo helo awood sare oo koronto ah iyo caabbinta kulaylka ilaa 105 darajo. Dabaysha LV waxay shaqaaleysiisaa xariijimo aluminium ah, oo bixisa aag ballaaran oo dusha sare ah, qaboojin la wanaajiyay, iyo waxqabadka korantada ee deggan xaaladaha culeyska culus.

2.3 Haanta

Haanta waxaa laga sameeyay bir khafiif ah oo leh jir cylindrical ah iyo dabool daboolan oo la go'i karo, oo lagu dhameeyay RAL7035 rinji. Looma ogola kormeerid ama adeeg furan Laba xajin oo xoog leh oo dhumucdiisu tahay ugu yaraan 3.4 mm ayaa lagu dhejiyay taangiga. Cidhifyada waxaa loo laabo si habboon. Dhammaan alxanka waa inay ahaadaan kuwo siman oo siman. Waa in aanay lahayn godad oo waa in la jeexo alxanka ka dib.
2.4 Kulanka ugu dambeeya
1. Golaha dabaysha:U jiid dabaylaha HV/LV oo dul saar xudunta dahaarka leh, adoo hubinaya toosinta saxda ah iyo hufnaanta dahaarka.
2. Isku xirka Korontada:Isku-xidhka dabaysha waxay u horseedaa beddelka tuubada, baadiyaha, iyo qaybaha kale, ka dibna ilaali oo dahaadh kala-goysyada.
3. Xudunta - Qalajinta gariiradda:Geli qaybta firfircoon ee la soo ururiyey (core + windings) foornada qallajisa si loogu kululeeyo faakuumka si looga saaro qoyaanka.
4. Rakibaadda Haamaha:Ku rid qaybta firfircoon ee engegan taangiga, u dhig si ammaan ah, oo hubi in dahaarka saxda ah ee gidaarada haanta.
5. Kordhinta Agabka:Ku rakib bushings, valve gargaarka cadaadiska iyo qalabyada kale, ka dibna ka hubi inay jiraan.
6. Buuxinta & Dejinta Saliidda:Vacuum-ku buuxi saliid dahaarka, degsooyinka, oo oggolow degitaanka ka hor intaadan hubin heerarka saliidda iyo xoogga tamarta.

03 Tijaabinta
Imtixaanka Heerka iyo Imtixaanka Joogtada ah
IEEE C57.12.20 -2017: IEEE Heerka Sarrifka Nooca Qaybta Sare 500 kVA iyo ka yar; Voltage Sare,34500 V iyo Hoos; Voltage Low,7970/13 800YV iyo Hoos
IEEE C57.12.90 -2021: IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and regulating Transformers
CSA C802.1 -13(R2022): Qiimaha hufnaanta ugu yar ee transformers qaybinta dareeraha ka buuxo
1. Cabbiraadaha iska caabinta
2. Imtixaanada saamiga
3. Tijaabada Polarity
4. Wax Khasaare ah oo Xamuul ah oo Hadda socda ma jiro
5. Load Khasaaraha iyo Korantada Waxyeelada
6. Tijaabada Voltage ee la dabaqay
7. Tijaabada adkaysiga korantada ee keentay
8. Cabbirka iska caabbinta dahaarka
9. Tijaabada Diidida oo leh Cadaadis loogu talagalay Beddeleyaasha Dareeraha Immersed
10. Tijaabada Dielectric Oil
04 Baakaynta iyo dhoofinta

05 Goobta iyo Kooban

Halbeegga 100 kVA - tiirka wejiga -ku dhejiyay taransfoorayaasha wuxuu u shaqeeyaa shabakadaha qaybinta sare ee Waqooyiga Ameerika. Waxay siisaa awood la isku halayn karo guryaha iyo ganacsiyada yaryar. Waxay isticmaashaa saliidda ONAN qaboojinta. Dabayshu waxay ka samaysan yihiin - naxaas iyo aluminium tayo sare leh. Haangu waa xoog badan yahay oo waa la xidhay si loo isticmaalo waqti dheer. Ma laha wax - wax ka beddelka tuubada ee hagaajinta korantada. Transformer-ku wuxuu u shaqeeyaa xasilloon oo hufan. Scotech waxay si taxadar leh u sameysaa transformer kasta. Unug kastaa wuxuu la kulmaa heerarka caalamiga ah.
Hot Tags: Transformer tiirka iftiinka, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
75 kVA Nooca Cirifka -34.5 / 0.12 * 0.24 kV|Kanada 2024
100 kVA Beddelka Cirifka Taleefanka-34.5/0.24 kV|USA...
150 kVA Pmt Transformer-19.92/0.24*0.12 kV|Kanada 2024
167 kVA Cooper Pad Ku rakiban Beddelka-13.8/0.24 kV|...
167 kVA Badelaha Qaybinta Cirifka-14.4/0.6 kV|Kanada...
50 kVA Transformer Dusha Korontada-7.97/0.12/0.24 kV...