75 KVA Dhintay Beddelka Hore-22.86/0.48 KV|USA 2024

75 KVA Dhintay Beddelka Hore-22.86/0.48 KV|USA 2024

Dalka la geynayo: Ameerika 2024
Awoodda: 75kVA
Voltage: 22.86GrdY/13.2-0.48kV
Tilmaam: Shan{0}} xudunta lugaha
U dir sooji

 

75 kva pole mounted transformer-front-door-open

Shan-Naqshad udub dhexaadka lugaha oo loogu talagalay xasilooni sare iyo hufnaan - tayo sare leh -

 

 

01 Guud

1.1 Sharaxaada Mashruuca

Kuwaas75 kVA saddex - suufka wejiga - ku rakiban transformerswaxaa sameeyay Scotech. Waxaa loo diray Maraykanka 2024. Waxay la kullan yihiin heerarka IEEE/ANSI waxayna si fiican ula shaqeeyaan nidaamyada qaybinta Waqooyiga Ameerika. Qaybta hore{3}}Qaylka, dhintay-Nashqada hore waxay ka saartaa qaybaha nool ee bannaan waxayna siinaysaa badbaado heer sare ah. Way fududahay in la hubiyo oo la ilaaliyo, dhammaan qaybaha tamarta lehna way xidhan yihiin oo daboolan yihiin.

Transformer-ka hore ee 75 kVA ee dhintay waxa uu leeyahay shan{1}}xuddun lugeed oo ka samaysan sare{2}}qabow{3}} xaashiyo bir ah oo silikon duuban oo leh tallaabo{4}}labo-goysyada dhabta. Waxa loo sameeyay si ay u buuxiso tamarta{6}heerarka qalabka oo ay leedahay 99.03% hufnaan. Wareega birlabeedka oo la hagaajiyay iyo - luminta dabaylaha aluminiumku waxa ay yareeyaan qashinka tamarta. Waxay sidoo kale kaydiyaan lacag waqti ka dib waxayna ilaaliyaan deegaanka.

Transformer-ka waxaa loogu talagalay 2400/4180Y ama 13200/22860Y nidaamyada wye salka ku haya, oo si deggan ugu shaqeeya xaaladaha adeegga caadiga ah. Waxa ay siisaa awood nabdoon oo hufan ee shabakadaha qaybinta magaalooyinka, warshadaha, iyo ganacsiga, taageerta nidaamka loop dhexdhexaadka ah iyo hoose- ee Waqooyiga Ameerika oo dhan.

 

 

1.2 Tilmaamaha Farsamada

75 kVA oo dhintay tafaftiraha hore iyo xaashida xogta

loo geeyey
Ameerika
Sannadka
2024
Nooca
Saddex weji suuf Buur Transformer
Heerka
IEEE Std C57.12.34
Awood lagu qiimeeyay
75 KVA
Soo noqnoqoshada
60HZ
Quudinta
Loop
Hore
dhintay
Marxaladda
Saddex
Tirada lugta xudunta ah
5
Nooca qaboojinta
ONAN
Insulant dareere ah
Saliidda Macdanta
Korantada aasaasiga ah
22.86GRDY/13.2 kV
Voltage Secondary
0.48y/0.208 kV
Kooxda Vector
YNyn0
Qalabka dabaysha
Aluminium
Caqabada
Ka weyn ama la mid ah 2.7%
Waxtarka
99.03%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
280 W
Load Lumista
1070 W
Agabka
Habaynta caadiga ah

 

1.3 Sawirro

75 kVA oo dhintay sawir beddelka hore iyo saxanka.

75 kVA dead front transformer drawing 75 kVA dead front transformer nameplate

 

 

02 Wax-soo-saarka

2.1 Core

75 kVA suuf {{1} ku rakiban Transformer wuxuu qaataa nashqad xudunta u ah shan{2} addin si loo hubiyo wadooyinka qulqulka magnetic summetrical, buuq yar, iyo hoos u dhaca khasaaraha Qaab dhismeedkani wuxuu bixiyaa dariiq xiran oo eber{4}} isku xigxiga isku xirka Y–Y, wuxuu wanaajiyaa-xoogga wareega, wuxuuna ogolyahay qaabka haanta cufan ee ku haboon loop{6}} quudinta dhintay{{7}qaabaynta hore ee sida caadiga ah loo isticmaalo shabakadaha qaybinta Waqooyiga Ameerika.

75 kva pole mounted transformer-five-limb-iron-core

 

2.2 Dabaylaha

75 kva pole mounted transformer-aluminum-winding

Dabaylaha HV iyo LV waxay ka samaysan yihiin dabaylo aluminium tayo sare leh -, hubinta dheelitirnaanta u dhexeeya hufnaanta, qiimaha, iyo waxqabadka kulaylka. Dabayshu waxay isticmaashaa hababka dabaylaha lakabka iyo helicalka leh dulqaadka cufan ee cabbirka si loo gaadho awood koronto oo aad u fiican iyo falcelinta dareere hoose. Farsamayaqaanadeena khibradda leh waxaa loo tababaray si xirfadaysan si ay u hubiyaan in dabaylaha kastaa uu yahay mid lebbisan, si farsamaysan ammaan u yahay, oo ka madax bannaan qallooc ama waxyeello dahaarka.

 

2.3 Haanta

Dhammaan qaybaha birta ah ee taangiga beddelka iyo qaybaha si fiican ayaa loo nadiifiyaa oo loo sii daaweeyaa ka hor rinjiyeynta si loo hubiyo adkeysiga adag iyo iska caabinta daxalka. Wixii dheeraad ah oo ka-hortagga -waxqabadka daxalka, 4ta inch ee hoose ee taangiga iyo qaybta waxa lagu dahaadhay dhuxul{3}}tar epoxy ama wax u dhigma{4}}daahan ilaalinta waajibka ah, hubinta- adkaysiga muddada dheer ee qoyaanka, ciidda, iyo bay'adaha adag ee dibadda.

75 kva pole mounted-transformer-oil-tank

 

2.4 Kulanka ugu dambeeya

75 kva pole mounted transformer-core and windings assembly
75 kva pole mounted transformer-activepart

 

Xuddunta iyo Golaha Dabayluhu
Nadiifi oo hubi xudunta. Rakib dabaylaha, xirmooyinka sugan iyo taageerooyinka dahaarka.

Rakibaadda Haanta Transformer
Hubi in haanta ay nadiif tahay oo kor u qaad qalabka wax lagu beddelayo. Isku toosi booska, hagaaji shimska iyo taageereyaasha, oo xidh.

Rakibaadda Qalabka Transformer
Ku rakib qalabka wax qaadista, qalabka cadaadiska cadaadiska, tilmaamayaasha heerka saliidda, dareeraha iyo agabka muunad, daloollada, qufullada, boolaladaha, Bay{{0}O-Fiyuusyada saafiga ah, beddelka tuubada, iyo cillad-sheegaha gudaha (IFD).

Buuxinta saliidda iyo xiridda
Vacuum-ku buuxi saliidda ilaa heerka caadiga ah oo hubi dhamaan shaabadihii soo daadanaya

Isku xirka Korontada iyo Tijaabada
Dhameystiran mid sare - iyo mid hoose - isku xirka korantada, xaqiiji booska beddelka tuubada, oo samee dahaarka, tamarta, dhulka, iyo tijaabooyinka daadinta.

Dibadda iyo Aqoonsiga
Nadiifi haanta iyo hiitarka, baadh ranjiga iyo lakabyada ka-hortagga daxalka, oo hubi xargaha magaca, calaamadaynta terminalka, iyo jaantusyada fiilooyinka.
 

 

03 Tijaabinta

Heerka Imtixaanka

IEEE C57.12.00-2021

Heerka IEEE ee Shuruudaha Guud ee Dareere -Qaybinta Immersed, Power, and Regulating Transformers

IEEE Std C57.12.34-2022

Shuruudaha Heerka IEEE ee suufka -Ku rakiban, Qayb{1}}Nooca, Nafta{2}}

La qaboojiyey, Saddex{0}}Wajiga Qaybinta Qaybinta, 10 MVA iyo Ka Yar; Sare -Voltage, 34.5 kV Voltage Nidaamka Magaca ah iyo Hoos; Hooseeyo-Voltage, 15kV

Voltage System Magac ahaan iyo Hoos

IEEE C57.12.90-2021

Xeerka Imtixaanka Heerka IEEE ee Dareere -Qaybinta Immersed, Power, and Regulating Transformer

 

Imtixaanka joogtada ah

1. Cabbiraadaha iska caabinta
2. Imtixaanada saamiga
3. Imtixaanka xidhiidhka wejiga
4. Wax Khasaare ah oo Xamuul ah oo Hadda socda ma jiro
5. Load Khasaaraha Waxyeelaynta Korantada iyo hufnaanta
6. Tijaabada Voltage ee la dabaqay
7. Tijaabada adkaysiga korantada ee keentay
8. Tijaabada Diidida oo leh Cadaadis loogu talagalay beddelayaasha Dareeraha Immersed
9. Cabbirka iska caabbinta dahaarka
10. Oil Dielectric test

75 kva pole mounted transformer-ratio-tests

 

75 kva pole mounted transformer-routine-test
75 kva pole mounted transformer-factory-test

 

04 Baakaynta iyo dhoofinta

4.1 Baakad

75 kVA pad-mounted transformer packing
75 kVA pad-mounted transformer foil bag


 

4.2 dhoofinta

Kahor intaanad soo shubin, cabbir cabbirka cabbirka iyo miisaanka, oo qorshee waddo ka fogaanaysa xannibaadaha dhererka, ballaca iyo miisaanka. Isticmaal sariir hoose{1} ama baabuur khaas ah oo leh awood ku filan.
Ku toosi xarunta taransfoorka ee culeyska iyo gaariga. Isticmaal birta kanaalka iyo hababka saxda ah si aad saldhiga ugu sugo gaadhiga, haddii la ogolaado. Ku xafid transformer-ka wadhafyo ama silsilado adigoo isticmaalaya godadka gaadiidka ee loo qoondeeyay, iskana ilaali waxyaabaha jilicsan sida hiitarka iyo kaymaha. Quful qaybaha gudaha oo xidh dhammaan albaabada.
Xawaaraha ka dhig wax ka yar ama la mid ah 60 km/h una leexo In ka yar ama la mid ah 15 digrii inta lagu jiro gaadiidka. Ka fogow dhaqdhaqaaqyada degdega ah iyo gariirka xooggan. U qoondee galbiyeyaasha si ay u hubiyaan xidhitaanka una joojiyaan gaadiidka marka ay cimiladu daran tahay.
Markaad kor u qaadayso, ku hay xaglaha xargaha in ka yar ama la siman 60 digrii . Isticmaal baararka faafinta haddii loo baahdo. Had iyo jeer si toos ah u qaad, iyo cutubyada aan lahayn lugaha sare, isticmaal ulo-qaadista hoose.

75 kva pole mounted transformer-shipping

 

 

05 Goobta iyo Kooban

75 kva pole mounted transformer-front-view

Tani75 kVA saddex - suufka wejiga - ku rakiban taransfooriyahaby Scotech waxa la geeyey Maraykanka 2024. Waxa ay leedahay hufnaan sare, waxqabad xoog leh, iyo naqshad adag. Dabaylaha xudunta u ah iyo aluminiumku waxay yareeyaan luminta tamarta. Naqshadaynta nabdoon, is haysta ayaa ka dhigaysa rakibaadda iyo dayactirka mid fudud. Waxay si fiican ugu shaqaysaa qaybinta awooda magaalooyinka iyo ganacsiga waxayna siisa - qiimo wakhti dheer ah iyo adeeg la isku halayn karo.

 