2500 KVA Ground Mount Transformer-12.47/0.6 ​​KV|USA 2025

2500 KVA Ground Mount Transformer-12.47/0.6 ​​KV|USA 2025

Dalka: USA 2025
Awoodda: 2500 kVA
Voltage: 12.47 / 0.6kV
Muuqaalka: oo leh saliid FR3
U dir sooji

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha ugu kalsoonida badan ee 2500 kva USA 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

 

ground mount transformer

Bixinta Tamarta, Ilaalinta Qiimaha: Sarriflayaasha suufka sare leh.

 

 

01 Guud

1.1 Sharaxaada Mashruuca

2500 kVA dhul-bedelka koronto ayaa la geeyey USA 2025. Awoodda la qiimeeyay ee transformerku waa 2500 kVA oo leh qaboojinta KNAN. Korontada sare waa 12.47GRDY/7.2 kV oo leh ±2*2.5% taping range (NLTC), danab hoose waa 0.6Y/0.346 kV, waxay samaysteen koox vector ah YNyn0.

Transformer-ku waxa uu qaataa saddex{0} waji sadex{1}} qaab dhismeedka xudunta addinka, kaas oo hubiya waxqabadka wareegga birlabeedka, si wax ku ool ah u yareeya luminta birta, oo wanaajisa isku halaynta shaqada. Waxaa ka buuxsamay saliid FR3 sida dahaarka iyo dhexdhexaadiyaha qaboojinta, -saliid tayo sare leh oo deegaanka u saaxiib ah oo ku faanta xasilooni kulayl aad u fiican, iska caabin dabka iyo biodegradability, siinta ilaalin dhamaystiran qaybaha gudaha ee transformerka iyadoo la raacayo shuruudaha ilaalinta deegaanka.

Marka la eego hufnaanta tamarta, alaabtu waxay si adag ugu hoggaansantaa heerarka hufnaanta DOE, iyada oo la wanaajinayo naqshadaynta xudunta u ah iyo dabaylaha si loo yareeyo khasaaraha iyo rarka luminta, garashada badbaadinta tamarta iyo dhimista isticmaalka inta lagu jiro muddada dheer{1} hawlgalka, iyo u keenaya faa'iidooyin dhaqaale oo la taaban karo isticmaalayaasha. Si loo hubiyo hawlgal badbaado leh, transformer-ku waxa uu ku qalabaysan yahay shaadh go'doon ah oo dhulka hoostiisa ah, kuwaas oo si gaar ah loogu isticmaalo nidaamka gaashaandhigga dhulka. Qaabayntani waxay si wax ku ool ah u cabudhi kartaa faragelinta korantada, yaraynaysaa dareeraha qayb ahaan, iyo ka ilaalinta transformerka khataraha korantada ee iman kara, hubinta badbaadada qalabka iyo xadhkaha korantada.

Dibadda, transformer-ku wuxuu leeyahay dhammaystir cad oo budo ah (RAL 9003), kaas oo aan kaliya bixinaynin iska caabin daxalka wanaagsan iyo iska caabinta cimilada si uu ula qabsado jawiga adag ee bannaanka ee kala duwan, laakiin sidoo kale wuxuu soo bandhigayaa muuqaal nadiif ah oo nadiif ah, isagoo si fiican ugu daraya xaalado rakibo kala duwan. Guud ahaan, koronto-sameeyahaan suufka lagu rakibay wuxuu isku daraa ilaalinta deegaanka, hufnaanta sare, badbaadada iyo adkeysiga, taasoo ka dhigaysa doorasho ku habboon mashaariicda qaybinta korontada ee magaalooyinka iyo miyiga.

 

 

 

1.2 Tilmaamaha Farsamada

2500 kVA dhulka ku dhajinta qalabka beddelka nooca iyo xaashida xogta

loo geeyey
USA
Sannadka
2025
Nooca
suuf ku rakiban transformer
Heerka
IEEE Std C57.12.34-2022
Awood lagu qiimeeyay
2500 kVA
Soo noqnoqoshada
60HZ
Marxaladda
3
Quudinta
Loop
Hore
dhintay
Nooca qaboojinta
KNAN
Korantada aasaasiga ah
12.47GRDY/7.2 kV
Voltage Secondary
0.6Y/0.346 kV
Qalabka dabaysha
Aluminium
Kooxda Vector
YNyn0
Caqabada
5.75%
Waxtarka
99.53%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
2.4 kW
Load Lumista
15.79 kW

 

1.3 Sawirro

2500 kVA suuf ku rakiban jaantuska beddelka sawirka iyo cabbirka.

ground mount transformer diagram ground mount transformer nameplate

 

 

02 Wax-soo-saarka

2.1 H0 baadiyaha

H0 Bushing

Hilibka H0 ee ku yaala isbedbedelka buurta dhulka waa mid si buuxda -gaashaamaysan, hoos loo dhigi karo{2}} interface la qiimeeyey ee isku xidhka fiilooyinka sare ee dhulka hoostiisa - (sida caadiga ah 15/25 kV). Naqshadaynta elastomeric-ka kooban, hal - waxay bixisaa xidhiidh gebi ahaanba badbaado leh, -oo aan soo bandhigin iyadoo la isku xidhayo gaashaanka hawada sare ee dhulka. Astaamaha muhiimka ah waxaa ka mid ah inta badan barta tijaabada iyo waxyaalaha lagu xidho - ee agabyada sida tusayaasha khaladka ah ama xidhayaasha, taas oo ka dhigaysa mid adag, dayactirka{11}} qayb bilaash ah oo loogu talagalay nidaamyada qaybinta dhulka hoostiisa.

 

2.2 Laba Boos Loadbreak Switch

Labada-labada boos jebinta culayska daaranaha isbedbedelka buurta dhulka waa qayb muhiim ah oo kaantaroolka nidaamka qaybinta dhulka hoostiisa ah, oo wata kaliya laba dawladood oo shaqaynaya: " xidhan" si loo tamarsiiyo wareegga iyo "furan" si loo tamarsiiyo -, iyada oo aan lahayn jagooyin dhexe. Waxaa loo habeeyay in si badbaado leh loo sameeyo oo loo jebiyo qulqulka culeyska marka loo eego xaaladaha shaqada ee caadiga ah, furayaasha badan oo noocan oo kale ah ayaa badanaa la geeyaa si isku mid ah si ay awood ugu yeeshaan kontoroolka dabacsan ee waddooyinka wareegga kala duwan (tusaale, A iyo khadadka quudiyaha B), taageeraya qaybinta awood la isku halayn karo laga bilaabo beddelka ilaa shabkada.

Two Position Loadbreak Switch

 

2.3 Taageerada Bushing LV

LV Bushing Support

Taageerada baadiyaha LV ee suufka -Transformers-ku rakiban waa qalab difaac oo muhiim ah kaas oo quseeya xiisadda kor u kaca ilaa hoose{1}}Xubabka korantada, ka hortagaya culeyska hoose ee fiilooyinka badan ee ku xiran{{2}gaar ahaan marka 8 ama in ka badan oo fiilooyinka la rakibo ama la isticmaalo balaarinta. Iyada oo yaraynaysa culayska ka saaran golaha baadiyaha iyo gaaskeeda xidhidhiyaha, waxay ka hortagtaa in gasket-ka lagu burburiyo gidaarka taangiga transformer-ka, si ay uga fogaato daadinta saliidda beddelka iyo ilaalinta shaabadda hermetic muddo dheer-isku halaynta hawlgelinta muddada dheer.

 

2.4 Gaashaanka dhulka

Gaashaanka dhulka ee is beddelka buurta dhulka waa lakabka dhaqdhaqaajinta muhiimka ah, sida caadiga ah ku xiran awoodda dhulka, kaas oo ku wareegsan qaybaha gudaha ee nool. Shaqadeeda aasaasiga ah waa in ay hubiso badbaadada iyada oo ka kooban oo si badbaado leh u weecinaysa mawjadaha cilladaha dhulka, ka hortagga transformer-ka in uu noqdo mid tamar leh oo ilaalinaya shaqaalaha. Isla mar ahaantaana, waxay bixisaa ilaalinta muhiimka ah ee elektromagnetic, taas oo yaraynaysa faragelinta ka imanaysa deegaanka dibadda waxayna yaraynaysaa culayska dahaarka beddelka, taas oo kor u qaadaysa isku halaynta shaqada iyo cimri dhererka. Sifadan udub dhexaad u ah waxay taageertaa dalabaadka shabakadaha casriga ah ee adkeysiga iyo waafaqidka nidaamyada la socodka xaalada horumarinta shabakadaha awooda.

Grounding Shield

 

2.5 HV Bushing

HV Bushing

HV (sare{0}}voltage) buushka suufka ku rakiban {{1}Transformer-ku waa qayb xidhidh la dahaaran oo muhiim ah, oo caadi ahaan lagu heli karo qiimaynta danab ee 15KV, 25KV, iyo 35KV (tusaale, LBI200 taxane) oo u hogaansan heerarka IEEE 386. Waxa ay u adeegtaa sida isku xidhka u dhexeeya dabaylaha hore ee gudaha iyo fiilooyinka qaybinta dibadda, oo leh shaabadaysan, fur - nashqada leh oo leh agab dahaarka sida epoxy ama galaas{11}la xoojiyay resin naylon si loo hubiyo dahaarka sare ee korantada iyo xasiloonida farsamada. Kayntani waxay ka hortagtaa daadinta saliidda beddelka iyo qoyaanka / boodhka soo dhexgalka iyada oo la yaraynayo khataraha fallaadhaha inta lagu jiro dayactirka, taageeraya culayska nabdoon{13}} hawlgallada jebinta iyo goobta{14}}shaqada la beddeli karo ee qaybinta korontada dibadda ee la isku halayn karo.

 

 

03 Tijaabinta

Cabbiraadda iska caabbinta dahaadhka waa baadhitaan asaasi ah oo lagu ogaanayo suufka{0}ku rakibay transformers, oo loo sameeyo si loo qiimeeyo daacadnimada iyo tayada nidaamka dahaarka ee u dhexeeya dabaylaha iyo dabaylaha iyo dhulka dhexdooda. Sida caadiga ah waxaa lagu sameeyaa iyadoo la isticmaalayo megohmmeter (Megger), tijaabadu waxay khusaysaa danab sare oo DC ah si loo cabbiro caabbinta dahaarka. Akhriska sare, deggan wuxuu muujinayaa xoogga dielectric xoog leh iyo caafimaad leh, dahaar qallalan, halka qiimaha iska caabbinta hooseeya ama hoos u dhaca ay muujin karto arrimaha suurtagalka ah sida qoyaanka soo galaya, faddaraynta, gabowga dahaarka, ama dhaawaca jirka. Tijaabada joogtada ahi waxay muhiim u tahay dayactirka saadaalinta, ka caawinta ka hortagga guul-darrooyinka, hubinta badbaadada shaqaalaha, iyo kordhinta nolosha shaqo ee beddelka gudaha shabakadda qaybinta.

 

 

04 Goobta iyo Kooban

Doorashada suufkayaga -Transformers-ku rakiban macneheedu waa maalgelinta maaha kaliya qalabka korantada,laakin{1}} badqabka muddada dheer, qiimaha aan caadiga ahayn, iyo isku halaynta aan leexleexnayn ee shabakadaada qaybinta korontada. Iyada oo la adeegsanayo dhismahooda qallafsan, teknooloojiyada dhulka sare-u-qaadista iyo dahaarka, oo loo dhisay{3}}iyado diyaar u ah is dhexgalka grid smart, alaabtayadu waxay xaqiijiyaan waxqabadka la isku halayn karo ee meelaha ugu baahida badan iyadoo la wanaajinayo wadarta qiimaha lahaanshaha. U ogolow khibradeena injineernimada ee la xaqiijiyay iyo ka go'naanta tayada inay naga dhigaan lamaanahaaga aad ku kalsoon tahay si aad u dhisto shabakad badbaado leh, ka hufan, iyo adkaysi leh. Nala soo xidhiidh maanta si aad u hesho xalka ugu fiican ee awooda mashruucaaga.

product-1707-1280

 

Hot Tags: Transformer, saaraha, alaab-qeybiyaha, qiimaha, qiimaha

U dir sooji