1600 KVA 3 Wajiga Beddelka Dhulka-12/0.48 KV|USA 2025

1600 KVA 3 Wajiga Beddelka Dhulka-12/0.48 KV|USA 2025

Dalka: Jamaica 2025
Awoodda: 1600 kVA
Voltage: 12D-0.48Y/0.277 kV
Feature: oo leh nooca suxulka ee hillaaca
U dir sooji

Jiangshan Scotech Electric Company USA 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

 

3 phase transformer grounding

Degmooyin ganacsi oo kobcaya, Saddexda-Wajiga suufka -Kurbada la saaray.

 

 

01 Guud

1.1 Sharaxaada Mashruuca

1600 kVA saddex weji suuf ah oo ku rakiban transformer ayaa la geeyey USA sanadka 2025. Awooda lagu qiimeeyay taransfooriyaha waa 1600 kVA oo leh qaboojin KNAN. Korantada sare waa 12D kV oo leh ± 2 * 2.5% garaacida kala duwan (NLTC), danab hooseeya waa 0.48Y / 0.277 kV, waxay sameeyeen koox vector ah Dyn1.

3-da weji dhul dhigista waa mid sare -waxqabad, xal qaybinta korantada mas'uul ka ah deegaanka looguna talagalay in lagu kalsoonaan karo oo dhulka hoostiisa ah{2}}ilaa- beddelka awooda sare ee ganacsiga, warshadaha, iyo codsiyada deegaanka.

Waxaa lagu farsameeyay FR3® dareere ester dielectric dabiiciga ah, waxay keentaa badbaadada dabka oo sarreeya (barta dabka sare), waaritaanka deegaanka oo la xoojiyey (si sahal ah bayoolaji u noqon karaan), iyo nolosha qalabka oo la dheereeyey iyada oo loo marayo maaraynta qoyaanka sare iyo ilaalinta dahaarka. Cutubku waxa uu la kulmaa heerarka hufnaanta tamarta adag ee Waaxda Tamarta ee Maraykanka (DOE), iyada oo hubinaysa hoos u dhac weyn oo ku yimaadda khasaaraha xudunta iyo gariiradda ee wadarta qiimaha lahaanshaha ee hoose iyo hoos u dhaca raad kaarboon.

Si loo wanaajiyo ilaalinta nidaamka iyo cimri dhererka, transformerku waxa uu ku qalabaysan yahay xusul isku dhafan{0}}nooca xirayaasha qallafsan (dhabiyeyaasha hillaaca), siinaya ilaalin xad dhaaf ah oo la isku halayn karo si toos ah xidhiidhada aasaasiga ah ee is haysta, meel banaan{1}}nakhshad kaydinaysa. Lagu xareeyay meel adag, fara-marin{3}} xero adkaysi u leh oo lagu dhammeeyey budada-cadaan dahaarsan (RAL 9003), transformerku waxa uu bixiyaa muuqaal nadiif ah, muuqaal ahaan dhexdhexaad ah kaas oo si aan kala go 'lahayn ugu walaaqa magaalo iyo deegaan muuqaal leh iyada oo bixisa iska caabin aad u wanaagsan oo daxalka ah oo dheer{6}} soo jiidasho quruxeed waarta.

Isku darka tignoolajiyada sareeysa ee dielectric, hufnaanta tamarta la igmaday, ilaalinta isku dhafan, iyo waara, hoose{0}naqshad profile, transformerkan waxa loo dhisay badbaado, hufan, oo la isku halayn karo{1} hawlgal muddo dheer ah.

 

 

 

1.2 Tilmaamaha Farsamada

1600 kVA 3 nooca beddelka dhulka hoostiisa nooca iyo xaashida xogta

loo geeyey
USA
Sannadka
2025
Nooca
suuf ku rakiban transformer
Heerka
IEEE Std C57.12.34-2022
Awood lagu qiimeeyay
1600 kVA
Soo noqnoqoshada
60HZ
Marxaladda
3
Quudinta
Loop
Hore
dhintay
Nooca qaboojinta
KNAN
Korantada aasaasiga ah
12D kV
Voltage Secondary
0.48Y/0.277 kV
Qalabka dabaysha
Aluminium
Kooxda Vector
Dyn1
Caqabada
5.75%
Waxtarka
99.43%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
1.67 kW
Load Lumista
10.9 kW

 

1.3 Sawirro

1600 kVA suuf ku rakiban jaantuska beddelka sawirka iyo cabbirka.

3 phase transformer grounding diagram 3 phase transformer grounding nameplate

 

 

02 Wax-soo-saarka

2.1 Core

3 phase transformer grounding cores

SCOTECH 3 transformer grounding sifada sare -darajada, hadhuudhka{2}}Koojyada birta silikoon ku jihaysan ee loogu talagalay ultra{3}} luminta xudunta hoose iyo daadinta qulqulka birta ee ugu yar. Saxnaanta -Laminations-ka gooyay dahaarka sare-u-qaadista waxay yaraynaysaa jahawareerka hadda jira iyo khasaaraha hysteresis, hubinta waxtarka tamarta gaarka ah iyo soosaarka danab xasiloon xitaa marka lagu jiro xaaladaha culeyska isbedbeddelaya. Naqshadaynta aasaasiga ah, adag, kaliya ma kordhinayso ka faa'iidaysiga booska gudaha xayndaabka laakiin sidoo kale waxay kor u qaadaysaa xoogga farsamada si ay ugu adkaysato walaacyada deegaanka ee dibadda, bixinta waxqabad la isku halayn karo ee shabakadaha qaybinta awoodda deegaanka, ganacsiga, iyo warshadaha.

 

2.2 Bushing sare

suuf - ku rakiban transformer sare -Bushyada korantada (15/25/35kV 200A) waxay u hogaansantaa ANSI/IEEE 386 tafatirka, una adeegaya sidii isku xidhayaasha furaha ah ee la kala sooci karo xusulada loadbreak. Loogu talagaly si toos ah - isku dhafka iyo dayactirka goobta, waxay keenaan dahaar adag, torque aamin ah{9}}ku-habboonaanta ku salaysan, iyo waafaqid habdhaqanka dhulka ee caadiga ah, hubinta gudbinta tamarta degan shabakadaha qaybinta dibadda.

3 phase transformer grounding bushing

 

2.3 Qiyaasta Heerka Saliida

3 phase transformer grounding oil level gauge

suufka -Transformer's UHZ -01 cabirka heerka saliida waa badbaado, la isku halayn karo oo sahlan-si{4}lagu akhriyo aaladaha yar/dhexe{5}}saliida awooda{10} unugyo la qooyay, oo ka shaqaynaya -40 ~ 80 digrii , In ka yar 90% ama le'eg joogga; waxay isticmaashaa tilmaame birlabeed sabeyn ah (oo laga shaabadeeyey haanta saliidda) si ay u muujiso isbeddelka heerka saliidda waqtiga-dhabta ah, oo leh nolol adeeg dheer marka loo eego cabbiraadaha dhalooyinka waxayna u baahan tahay dhejis toosan oo aan lahayn gariir fiiqan ama faragelin xoog leh.

 

2.4 Heerkulbeegga

suufka -kuwa ku rakiban transformer's Heerkulbeegga BWS-70 waa aalad xasaasi ah, la isku halayn karo oo leh kiis bir ah (noolaha adeega dheer, muuqaal qurxoon) oo tilmaamaya heerkulka haanta; nalkeedu wuxuu u baahan yahay gelinta ka weyn ama le'eg 100mm dhexda si sax ah, waxay u baahan tahay ka ilaalin shil/ leexin, waxayna u baahan tahay jeegag sanadle ah si loo ilaaliyo akhrinta saxda ah.

Thermometer

 

2.5 Cadaadiska Relief Valve

pressure relief valve

suufka -Transformer-ka ee taxanaha YSF ee taxanaha cadaadiska cadaadiska wuxuu ka ilaaliyaa haanta cadaadiska xad dhaafka ah: si otomaatig ah ayuu u furmaa 10 psi (la habeyn karo) si uu u sii daayo gaaska ilaa cadaadiska nabdoon laga soo celinayo, waxay u ogolaataa cadaadiska gacanta ee hoos u dhaca iyada oo loo sii marayo hoop, wuxuu ku shaqeeyaa 0 ~ 80 digrii iyo<95% humidity, requires sealant for mounting, and avoids corrosion-prone environments.

 

2.6 Qiyaasta Cadaadiska Vacuum

suufka -ku rakiban YZ -70 vacuum cadaadiska cabbiraadaha kormeerayaasha hawlgalka iyadoo ka tarjumaysa isbeddelada cadaadiska heerkulka ku xidhan, bixiya kala duwanaansho la dooran karo (-0.04 ~ 0.04/-0.08 ~ 0.08MPa), ± 2.5% saxsanaanta, iyo M27×2 kor u qaadida furaha la hagaajin karo; Waxay ku shaqeysaa -40 ~ 80 digrii / In ka yar ama le'eg huurka 80%, waxay u baahan tahay rakibaad joogto ah, waxayna u baahan tahay hubin 6-bilood ah si loo helo waxqabad la isku halayn karo.

Vacuum Pressure Gauge

 

2.7 Suxulka Qabta

Suufka{0}ku rakibay Transformer's 15/25kV 200A suxulka xiraha fasalka wuxuu dhexgeliyaa moduleka birta oksaydhka varistor ee peroxide - xusul caag ah oo la daweeyey (IEEE 386{{12}u hoggaansan), siinta ilaalinta korantada ee nidaamyada dhulka hoostiisa ah ( beddelayaasha, qasnada, iwm.). Waxay bixisaa ilaalinta hore ee gaashaanka, oo leh astaamo ay ka mid yihiin 2.55-17.5kV MCCV iyo 7.7-53.6kV ugu badnaan korantada dareeraha ah (oo ah 10kA), oo lagu daray 223-235mm naqshado cabbirkoodu yahay rakibid fudud.

 

 

03 Tijaabinta

A 1600kVA 3 wejiga transformer grounding (qaabka: 12D-0.48Y/0.277kV, lambarka taxan: 250904) ayaa maray imtixaano joogto ah Oktoobar 22, 2025, si waafaqsan heerarka IEEE (C57.12.00{127}C57.12.00{127}C57.54,212,212.212.212.3.212.212.212.212.212.212.212.212,212,212,212,212.5. C57.12.90-2021). Tijaabooyinka waxaa ka mid ah cabbirka caabbinta dabaysha (ugu badnaan heerka dheelitir la'aanta 7.03%), imtixaanka saamiga korantada ( leexashada -0.07% ~ -0.05%), imtixaanka xidhiidhka-xiriirka (Vector group Dyn1), khasaare la'aan iyo cabbirka hadda (1.432kW, 0.23%), culayska culayska, korantada impedance iyo imtixaanka hufnaanta (10,5%) 9.9 Tijaabada danab (HV 34kV / 60s, LV 10kV / 60s), korantada keentay imtixaanka u adkeysiga (24kV, 150Hz, 48s), cabbirka caabbinta dahaarka (2.51-3.97GΩ), iyo tijaabada daadinta cadaadiska (20kPa, 24h). Dhammaan alaabtu waxay buuxisay shuruudaha aqbalaadda, iyada oo aan la arkin wax koronto ah ama daadsan.

voltage ratio test
applied voltage test

 

 

04 Baakaynta iyo dhoofinta

packing of 3 phase transformer grounding
xirxiran
shipping of 3 phase transformer grounding
maraakiibta

 

 

05 Goobta iyo Kooban

SCOTECH pad -Transformers rakiban: naqshad is haysta,{1}}waxqabad culus, eber wax u dhimaya badbaadada. Ku habboon xaalad kasta oo qaybinta awoodda, cutubyadayadu waxay isku daraan hal-abuurnimo iyo adkeysi si ay u ilaaliyaan hawlahaaga si habsami leh, maalin iyo maalinba. Dooro SCOTECH- lamaanahaaga lagu kalsoonaan karo si aad u hesho xalal awood badan oo caqli badan.

  • Waxtarka Tamarta ee la shahaadiyey ee la dhimay wadarta qiimaha lahaanshaha.
  • Hore u soco-Eegista Badbaadada Deegaanka & Dabka oo leh dareere FR3
  • Ilaalinta Nidaamka Adag iyada oo loo marayo xirayaasha isku dhafan ee u adkeysiga shabakada.
  • Waara iyo Bulsho{0}Naqshad saaxiibtinimo leh oo dhammaystiran oo si aan kala sooc lahayn ugu dhex milmay hareere kasta.

Waxaa naga go'an inaan bixino qalab koronto oo aan kaliya buuxin heerarka balse dhaafsan filashooyinka. Si aad u sahamiso tafaasiisha faahfaahsan, ikhtiyaarka habaynta, ama si aad ugala hadasho baahiyahaaga mashruuca gaarka ah, fadlan la xidhiidh iibka iyo kooxdayada injineernimada maanta.