1000 KVA Transformer 3 Wajiga-24/0.416*0.24*0.12 KV|Jamaica 2026

1000 KVA Transformer 3 Wajiga-24/0.416*0.24*0.12 KV|Jamaica 2026

Dalka: Jamaica 2026
Awoodda: 1000 kVA
Voltage: 24GrdY/13.8-0.416Y/0.24*0.24DkV
Muuqaalka: YNyn0/YNd11
U dir sooji

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha ugu kalsoonida badan ee 1000 kva transformer 3 wejiga{9}}24/0.416*0.24*0.12 kv|jamaica 2026 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. nala soo xidhiidh wixii faahfaahin ah

 

image001

Awood meesha aad uga baahan tahay, qurux halka aad ku aragto - taasi waa suuf ku rakiban transformer.

 

 

01 Guud

1.1 Sharaxaada Mashruuca

1000 kVA saddex weji suuf ah oo ku rakiban transformer ayaa la geeyey USA 2026. Awoodda lagu qiimeeyay transformerku waa 1000 kVA oo leh qaboojin KNAN. Korantada sare waa 24GrdY/13.8kV oo leh ±2*2.5% garaacid (NLTC), danab yar waa 0.416Y/0.24*0.24D kV, waxay samaysteen laba kooxood oo kala ah YNyn0/YNd11.

Dual Low-Kooxda Iskudubbada Voltage ee Beddelka Korantada

Sifada gaarka ah ee mashruucan waa qaabaynta kooxda qaabaynta korantada yar ee korantada, oo loo qaabeeyey sida YNyn0/YNd11. In xidhiidhka YNyn0, labada danab sare iyo dabaylaha danab yar yihiin xiddigaha ku xiran dhibcood dhexdhexaad ah soo baxay, iyo dhinaca danab hooseeyo weli in wejiga la dhinaca danab sare. Qaabeynta YNd11, dabaysha danab yar ayaa ku xiran delta, taasoo keentay 30 darajo wejiga hogaanka (ama 330 digrii) marka loo eego dhinaca korantada sare. Naqshadaynta kooxdan laba-geesoodka ah waxay awood u siinaysaa beddelaad dabacsan oo u dhexeeya qaabaynta wax-soo-saarka danab hoose ee kala duwan, taasoo u oggolaanaysa macaamilka inuu la qabsado sifooyinka korantada labaad ee beddelka si uu ula kulmo shuruudaha nidaamka kala duwan. Iyada oo loo marayo isku xirka gudaha dib loo habeyn karo iyo isticmaalka barta dhexdhexaadka ah, transformer-ku wuxuu bixin karaa ma aha oo kaliya heerka 0.416 kV (line to line) iyo 0.24 kV (khadka dhexdhexaadka ah / delta), laakiin sidoo kale 0.12 kV tuubada korantada hoose, oo bixisa ikhtiyaar saddexaad oo loogu talagalay culeysyo khaas ah ama baahiyaha saadka. Kala duwanaanshiyahan la xoojiyey ayaa ka dhigaya transformers-yadan si gaar ah ugu habboon xaaladaha kala duwan ee isku xirka shabakadaha iyo codsiyada korantada badan.

Shuruudaha Imtixaanka Nooca: Cabbirka Iska caabinta Dabaysha ee DC

Marka laga soo tago imtixaanada caadiga ah ee lagu sheegay hab-maamuuska farsamada, mashruucani waxa uu xambaarsan yahay shuruud gaar ah: Cabbirka iska caabbinta dabaysha ee DC waxa loo qoondeeyay sidii tijaabo nooc qasab ah. Tijaabadani waxay ku lug leedahay duritaanka hadda DC-ga ee la kantaroolo ee rogrogmato kasta iyo cabbirida hoos u dhaca danab si loo xisaabiyo qiyamka iska caabinta. Tijaabada iska caabinta dabaysha DC waa qalab ogaanshaha muhiimka ah ee loo isticmaalo in lagu garto joojinta, xidhiidhada liidata, iyo wareegyada furan ee dabaylaha dhexdooda, iyo sidoo kale si loo xaqiijiyo daacadnimada dhammaan xidhiidhada tuubada. Samaynta tijaabadan sidii imtixaan nooc ah halkii ay ka ahaan lahayd imtixaan joogto ah, macmiilku waxa uu helayaa hubin heer sare ah oo ku saabsan sii wadida dabaylaha, tayada isku xidhka, iyo saxnaanta guud ee wax soo saarka transformers-yadan{3}Tixgalin gaar ah oo muhiim ah marka la eego nashqada kooxda{{4}vector-iyo baahida loo qabo waxqabad la isku halayn karo ee hoos yimaada isku xidhka labadaba.

 

1.2 Tilmaamaha Farsamada

1000 kVA suuf ku rakiban nooca tafatirka beddelka iyo xaashida xogta

loo geeyey
Jamaica
Sannadka
2026
Nooca
suuf ku rakiban transformer
Heerka
IEEE Std C57.12.34-2022
Awood lagu qiimeeyay
1000 kVA
Soo noqnoqda
50HZ
Marxaladda
3
Quudinta
Loop
Hore
dhintay
Nooca qaboojinta
ONAN
Korantada aasaasiga ah
24GrdY/13.8kV
Voltage Secondary
0.416Y/0.24*0.24 kV
Qalabka dabaysha
Copper
Kooxda Vector
YNyn0/YNd11
Caqabada
5.75%
Waxtarka
99.06%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
1.5 kW
Load Lumista
14.32 kW

 

1.3 Sawirro

1000 kVA suuf ku rakiban jaantuska beddelka sawirka iyo cabbirka.

image003

image005

image007

 

 

02 Wax-soo-saarka

2.1 Dabaylaha

image009

Dabaylaha beddelka ayaa lagu soo saaray 100% naxaas elektrolytic ah si loo hubiyo dhaqdhaqaaqa wanaagsan, xoogga wareegga gaaban ee sarreeya, iyo xasilloonida kuleylka muddada dheer. Xuddunta waa nakhshad 5 lugood ah oo laga dhisay awood sare leh, qabow duuban, bir silikoon ku jihaysan hadhuudh, oo si sax ah loo dulsaaray si loo yareeyo magnetization-ka hadda iyo khasaaraha leexsan. Habaynta 5 lugta ayaa si gaar ah faa'iido u leh qaabaynta kooxda laba-geesoodka ah (YNyn0/YNd11), maadaama ay dheellitirayso qaybinta qulqulka ee labada isku xidhka xiddigaha iyo delta, taaso hoos u dhigaysa la'aanta culeyska iyo xiisaha hadda.

 

2.2 LV Usha Sameeyaha (kooban)

Dhinaca korantada yar waxay isticmaashaa ulaha korantada naxaasta ah ee daasaddaysan (busbars) kuwaas oo ku xidha terminalyada dabaysha iyo nooca caarada ee LV. Ulahan waxa loo cabiray si ay u qaadaan heerka qiimaynta buuxda ee hadda (qiyaastii{1}} A at 416 V) oo leh xad ku filan, waxaana loo qaabeeyey inay u adkaystaan ​​culaysyada wareegga gaaban ee firfircoon iyo kulaylka iyada oo aan qalloocin. Ulaha ayaa si ammaan ah u dahaaran oo lagu taageeray gudaha taangiga si loo hubiyo iska caabin hoose, dayactirka ku xirnaanta bilaashka ah inta uu nool yahay beddelka.

image011

 

2.3 Laba Boos Loadbreak Switch

image013

Seddex FYB 10 nooca laba boos oo saliid ah oo lagu shubay shiishadaha xamuulka qaada ayaa lagu rakibay qolka HV. Waxaa lagu qiimeeyay 10 kV, 630 A, oo leh kulayl u adkeysanaya 20 kA/2s, adkaysi firfircoon oo 50 kA ah (ugu sarreysa), iyo nolol farsamo oo ah 2000 hawlgal. Furayaasha waxaa loo habeeyey codsiyada loop-ka (laba loop in/out, mid loogu talagalay ilaalinta beddelka), oo leh gacan-qabasho la xiri karo oo laga heli karo qaybta hore.

 

2.4 H0 Bushing (HV dhexdhexaad ah)

Barta dhexdhexaadka ah ee korantada sare waxaa lagu soo saaraa geedo gaar ah oo H0 ah, kaas oo ah qaab ANSI ah oo ah laba dalool oo lagu qiimeeyay 25 kV, 208 A, oo leh masaafada gurguurta ee Ka weyn ama la mid ah 405 mm iyo BIL ah 125 kV. Terminalkan H0 ee goonida ah wuxuu u oggolaanayaa hab-dhisidda nidaamka dabacsan - dhex-dhexaadku wuxuu noqon karaa mid si adag loo qotomiyey, cidhiidhi galiyay, ama lagaga tagi karaa iyada oo aan dhulka la dhigin marka dabaysha HV ay ku xidhan tahay wye. Hawlgalka delta, baadiyaha H0 wuxuu u adeegaa sidii goob tijaabo ah oo ku habboon baarista dahaarka.
Intaa waxaa dheer, laba sariirood oo bir ah oo aan rinji lahayn (mid ka mid ah qayb kasta) ayaa la bixiyaa haanta la isku halayn karo iyo habaynta dhulka.

image015

 

2.5 Kulanka ugu dambeeya

image017

Isku soo wada duuboo waxay raacdaa qorshe tayo adag leh: xidhidhaynta xudunta u ah, dabaylaha gariiradda, xidhiidhka rasaasta, iyo cajaladaha dahaarka waxa lagu sameeyaa xaalado la xakameeyey. Qaybta firfircoon ee dhammaystiran waxay maraysaa habka qalajinta faakuumka iyo habka buuxinta saliidda si looga saaro qoyaanka dahaarka adag, hubinta nidaamka qalalan oo xasilloon ka hor xiritaanka haanta kama dambaysta ah.

Taangigu waa nooc dhisme oo xidhan oo leh dabool daboolan, oo ka samaysan bir khafiif ah. Xerada waxaa lagu dahaadhay Munsell 7GY3.29/1.5 dhammayn, oo buuxinaysa shuruudaha IEEE C57.12.28 ee iska caabinta daxalka ee deegaannada xeebaha. Lugaha kor u qaadida iyo suufka jackingka ayaa loo diyaariyey si badbaado leh loola tacaalo.

 

 

03 Tijaabinta

Dhammaan imtixaanada waxaa loo sameeyaa si waafaqsan IEEE C57.12.34 2022 iyo IEEE C57.12.90.
Tijaabooyin joogto ah (oo lagu sameeyo cutub kasta):
Qiyaasta leexashada iyo barokaca wajiga (YNyn0 iyo YNd11 waa la xaqiijiyay)
• Wax rar ah ma jiro iyo hadda xiiso leh
• Load luminta iyo danab-ka-hortagga
Korontada la dabaqay ee u adkeysiga (HV: 40 kV; LV: 10 kV)
• U adkaysiga danabku keenay
• Tijaabada daadinta haanta (50 kPa ilaa 12 saacadood)
• Quwada saliidda (Ka weyn ama la mid ah 45 kV)
• Iska caabbinta dahaarka DC iyo tusaha polarization
Nooca imtixaanada – shuruuda gaarka ah ee mashruucan ayaa ah in cabirka iska caabinta dabaysha ee DC loo qoondeeyay sidii tijaabo nooc qasab ah, ma aha oo kaliya hubinta caadiga ah. Tijaabadani waxa ay duraysaa dabaylaha DC ee la kantaroolay dabaylaha kasta oo waxa ay cabbirtaa hoos u dhaca danab si loo xisaabiyo qiyamka iska caabinta. Waa baadhis muhiim ah oo lagu ogaanayo xadhkaha jaban, isku xidhka leexashada dhexda ee liidata, ama kalagoysyada tuubada ee dabacsan. Anagoo u samaynayna tijaabo nooc ah, waxaanu bixinaa hubin heer sare ah oo ku saabsan sii wadida dabaylaha iyo isku xidhka - gaar ahaan muhiimada marka la eego labada qaabayn ee kooxeed ee kala duwan.

Laga soo bilaabo warbixinta imtixaanka la dhammeeyay (Serial No{0}}), qiimayaasha la cabiray:
• Wax rar ah ma jiro: 1.1445 kW
• Luminta culeyska (85 darajo): 12.037 kW
• Caqabada: 5.74%
Waxtarka: 99.23% - dhamaantood waxay dhaafeen tirooyinka la dammaanad qaaday.

image019
image021

 

 

04 walaaca macaamiisha

Dhowr qodob oo muhiim ah ayaa laga hadlay si loo daboolo baahiyaha gaarka ah ee macaamiisha Kanada:

Hawlgalka kooxda laba-geesoodka ah (YNyn0/YNd11): Xidhiidhada gudaha waxa loo qaabeeyey si dabaysha LV dib loogu habayn karo min xidig ilaa delta. Xiddigta, heerka korantada dhexdhexaadka ah waa 240 V iyo xariiqda xariiqda 416 V; gudaha delta, xariiqda xariiqda waxa ay ahaanaysaa 416 V, halka tuubada dhexe ee hal waji ay ku siinayso 120 0 120 V (ie, 0.12 kV) culaysyada caawimada ah. Beddelku waa mid toos ah, iyadoo la isticmaalayo taarikada isku xirka.
Nooca tijaabada ah ee loo baahan yahay: Macmiilku waxa uu waydiistay iska caabin dabaysha DC nooc tijaabo ah - tani waxa ay siinaysaa caddayn la duubay oo ah joogteynta wax soo saarka iyo tayada isku xidhka labada qaabayn ee dabaysha.
• Jawi xeebeed kulaylaha ah: Transformers-yada waxaa loo qaabeeyey iyadoo la xoojiyey ilaalinta daxalka (nidaamka rinjiga dhumucsan, qalabka birta aan lahayn) iyo heerar sare oo BIL ah si ay ugu adkaystaan ​​hillaaca soo noqnoqda, qoyaan badan, iyo hawada cusbada leh, sida ku cad qeexitaanka Jamaican (JPSCo 6950 S 04).
image023

 

 

05 Baakaynta iyo rarida

5.1 Baakad

Transformer kastaa si gaar ah ayaa loogu guray sanduuq alwaax ah oo culus, oo loogu talagalay maaraynta wiishka fargeetada iyo gaadiidka badda. Qaybaha xasaasiga ah (bushing porcelain, valve gargaarka cadaadiska, heerka cabbirka) waxaa intaa dheer oo lagu daboolay walxo shoog nuugaya. Sanduuqa waxa lagu calaamadeeyay calaamado "UP" iyo "FRAGILE". Heerka saliidda waxa lagu hayaa 100 150 mm ka hoosaysa taangiga sare si loogu oggolaado balaadhinta kulaylka inta lagu jiro safarka.

image025

 

5.2 dhoofinta

image027

Raritaanka waxaa loo sameeyay sidii unug dhamaystiran (si buuxda loo soo ururiyey, saliid la buuxiyey). Kahor intaan la dirin, ogolaansho qoraal ah ayaa looga baahan yahay iibsadaha, iyo warbixinada imtixaanada la xaqiijiyay waa in la soo gudbiyaa oo la oggolaadaa.

Transformers-yada waxa lagu raray CIF Kingston, Jamaica (ama sida ku cad deked lagu heshiiyey). Dhibcaha qaadista iyo hubinta ayaa si cad loo calaamadeeyay. Baakadaha alwaaxdu waxay u hoggaansamaan ISPM 15 heerarka phytosanitary ee maraakiibta caalamiga ah. Gariirka gaadiidka iyo shoogga ayaa lagu tixgaliyay qaabeynta taageerooyinka gudaha.

 

 

05 Goobta iyo kooban

SCOTECH suufka ku rakiban transformers waxaa lagu aaminay magaalooyinka, ganacsiga, warshadaha, iyo mashaariicda tamarta la cusboonaysiin karo. Waanu soo dhawaynaynaa su'aalahaaga iyo amaradaada gaarka ah - kooxdayada khabiiradu waxay diyaar u yihiin inay kaa caawiyaan doorashada ilaa ka dib taageerada iibka. Maanta nala soo xidhiidh - SCOTECH ha awoodo guushaada.

image029

 

Hot Tags: 1000 kva transformer 3 waji-24/0.416*0.24*0.12 kv|jamaica 2026, Shiinaha 1000 kva transformer 3 waji-24/0.416*0.24*0.12 kv|jamaica 2026 saarayaasha, alaab-qeybiyeyaal, warshad