25 Tiirka Utility ee KVA Ku rakiban Badaha-2.4/0.12 KV|Kanada 2025
Awoodda: 25kVA
Voltage: 2.4*14.4-0.12/0.24k
Tilmaam: Qabow aad u daran
Jiangshan Scotech Electric Company kanada 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. nala soo xidhiidh wixii faahfaahin ah

01 Guud
1.1 Macmiil & Aragtida Goobta
Dulmar: Transformer-kan waxaa loo doortay si loo xaqiijiyo hawlgal la isku halayn karo oo hufan oo hoos yimaada xaaladaha adag ee deegaanka ee NWT, Canada, taageeraya shabakadaha qaybinta ganacsi ee miyiga iyo kuwa fudud iyadoo la yareynayo shuruudaha dayactirka.
Shuruudaha Macmiilka ee Muhiimka ah:
• Waxay u shaqeysaa si la isku halleyn karo iyadoo lagu jiro qabow daran (hoos -52 darajo)
Ku habboon tiirka -ku rakiban ee ku yaala buuraha taiga
• Wax ka qabata qoyaan badan, culeyska barafka, dabaysha, iyo wasakhowga
• Wuxuu si hufan ugu shaqeeyaa culays qaybeed oo caadi ah (~ 60%)
Deegaanka Rakibaadda & Xaaladaha Goobta
|
Halbeegga |
Qiimaha |
|
Koritaanka |
Tirka{0}ku rakiban yahay, bannaanka |
|
Celceliska heerkulka jawiga |
-2 darajo |
|
Heerkulka deegaanka ugu badan |
35 darajo |
|
Heerkulka deegaanka ugu yar |
-52 darajo |
|
Heerkulka Kaydinta |
-55 darajo |
|
Celceliska Xawaaraha Dabaysha |
9.5 m/s |
|
Xawaaraha ugu badan ee Gust |
30 m/s |
|
Culayska Barafka ugu badan |
1000 mm |
|
Dhererka |
<300 m |
|
Heerarka Naqshadeynta |
U hogaansama shuruudaha dhismaha gobolka iyo seismic, Fort Smith, NWT, Canada |
Tixgelinta Codsiga:
• Dhererka cirifka ayaa bixiya qaboojin dabiici ah, markaa looma baahna baalal qaboojin dheeraad ah
Transformer-ku wuxuu u adeegaa guryaha iyo culaysyada ganacsi ee fudud ee shabakadaha qaybinta miyiga
1.2 Tilmaamaha Farsamada
25kVA hal weji oo tiir ah oo ku dhejinaya tafatirka tafatirka iyo xaashida xogta
|
loo geeyey
Kanada
|
|
Sannadka
2025
|
|
Nooca
Turjumaanka Cirifka leh
|
|
Heerka
CSA C2.2-06
|
|
Awood lagu qiimeeyay
25 KVA
|
|
Soo noqnoqda
60HZ
|
|
Polarity
Wax lagu daro
|
|
Marxaladda
1
|
|
Nooca qaboojinta
ONAN
|
|
Insulant dareere ah
Saliidda Macdanta
|
|
Korantada aasaasiga ah
4160GrdY/2400X
24940GrdY/14400 kV
|
|
Voltage Secondary
120/240 V
|
|
Kooxda Vector
ii6
|
|
Qalabka dabaysha
Copper
|
|
Caqabada
1.99/1.96 %
|
|
Waxtarka
98.87 %
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Wax Xamuul ah ma jiro
80 W
|
|
Load Lumista
282 W
|
|
Agabka
Habaynta caadiga ah
|
1.3 Sawirro
25kVA hal weji oo tiir ah oo ku dhejinaya sawir-qaadaha iyo sawirka magaceed
![]() |
![]() |
02 Naqshadeeynta Transformer ee Xaaladaha Kanada ee aadka u daran
2.1. Naqshadeynta xalalka isku halaynta

Si loo hubiyo waxqabadka muddada dheer- ee hoos yimaada cimilada adag ee NWT, Canada, transformerku waxa uu leeyahay dabaylaha naxaasta ah ee adag, ONAN qaboojinta kulaylka dabiiciga ah, iyo haanta bir khafiif ah oo xidhan oo leh cawl khafiif ah oo ilaalinaysa deegaanka.
2.2. Halbeegyada Farsamo ee Muhiimka ah
Transformer-ka waxaa loo dhisay heerarka CSA C2.2-06, oo leh kala duwanaansho koronto oo aasaasi ah oo ah 4160 GrdY/2400X - 24940 GrdY/14400 V, danab sare 120/240 V, kooxda vector Ii6, iyo hufnaan sare 98.87%. Beddelka tuubada NLTC wuxuu u oggolaanayaa hagaajinta korantada ganaaxa (± 2 × 2.5%) culeyska qaybinta miyiga, kaas oo sida caadiga ah ku shaqeeya qayb qayb ah (~ 60%).

2.3. Badbaadada iyo Astaamaha Shaqada
Naqshadaynta sare ee buushka korantada{0} waxa ku jira meesha sare{1}}ku rakiban H1 terminal leh 4-isku xidhka dariiqyada iyo H2 gudaha xidhidhyo xidhan, oo lagu xoojiyay ilaalada shimbiraha si looga hortago faragalinta duurjoogta. Hoose -Bushyada korantada waa dhinac{8}}ku rakiban terminal nooca xajin ah, iyo transformerka waxaa ku jira Aaladda Fuse Gudaha (IFD) ee ilaalinta khaladka gudaha.


Dual-Voltage Switch

03 Tijaabinta


Mid ka mid ah 271 Unug: Imtixaanka Heerka iyo Imtixaanka Joogtada ah

04 Qabow{1}Climate Tirka Cimilada -Beddelayaasha Rakaabka ah
Cirifka -Transformers ku rakiban ee ku shaqeeya jawi qabow daran, sida waqooyiga Kanada ama gobolada kale ee arctic, waxay u baahan yihiin laqabsasho naqshad gaar ah si loo hubiyo in la isku halayn karo, badbaado, iyo{2} waxqabad wakhti dheer ah. Qodobbada muhiimka ah waxaa ka mid ah:
Hooseeyo-Heerkulka{1}Qalabka u adkaysta:Isticmaalka hababka dahaarka, baadiyaha, iyo qaybaha dhisme ee awood u leh inay u adkeystaan qabow ba'an iyada oo aan dillaacin ama aan noqon mid jajaban.
Qabow- Saliid bedelaadaha iyo qaboojinta la hagaajiyay:Xulashada saliidaha macdanta ama macdanaha leh dhibco shub yar iyo ONAN (saliid -hawada dabiiciga ah{1}}dabiiciga ah) hababka qaboojinta ee loogu talagalay in lagu ilaaliyo kulaylka ku filan xitaa iyadoo qayb qayb ah.
Xidhan, Haanta aan Cimilada Cimiladu:Xayndaabka birta ah ee si buuxda u xidhan ayaa ka ilaalinaysa qoyaanka, barafka, barafka, iyo daxalka deegaanka, hubinta in qaybaha guduhu ay yihiin kuwo qalalan oo dahaaran.
Xoojinta Dhismaha:Taangiyada, xirmooyinka korka, iyo taageerooyinka loo farsameeyay inay u adkeystaan rarka barafka culus, dabaylaha xooggan, iyo dhaqdhaqaaqa seismic ee suurtagalka ah, iyadoo la ilaalinayo daacadnimada makaanikada heerkulka hooseeya.
Heerkulka iyo Isbarbardhigga Culayska:Qiimaynta beddelka, beddelayaasha tuubada, iyo xadka sare u kaca kulaylka ayaa la xisaabiyaa si loo hubiyo hawlgal badbaado leh oo hoos yimaada xaaladaha jawiga aadka u daran, xisaabinta kala duwanaanshaha rarka iyo isku halaynta muddada dheer{{0}
Marka la xalliyo arrimahan, tiirarka ku rakiban transformers{0} waxay bixin karaan adeeg hufan, badbaado leh, oo joogto ah qaar ka mid ah cimillada ugu xun dhulka, yaraynta dayactirka iyo kordhinta cimriga shaqada ee shabakadaha qaybinta miyi iyo fog.
Hot Tags: 25 kva utility tiir ku rakiban transformer-2.4/0.12 kv|kanada 2025, Shiinaha 25 kva utility tiir ku rakiban transformer-2.4/0.12 kv|kanada 2025 saarayaasha, alaab-qeybiyeyaal, warshad
You Might Also Like
15 kVA Tiirka Ku rakiban Beddelka-24.94/0.12*0.24 kV...
150 kVA Pmt Transformer-19.92/0.24*0.12 kV|Kanada 2024
500 kVA Tiirka Ku rakiban Badaha-24.94/0.6 kV|Kanada...
75 kVA Beddelka Sare-24.94/0.347 kV|Kanada 2025
167 KVA cirifka ugu sarreeya-34.5 / 0.347 KV|Kanada ...
75 KVA Transformer Cirifka Taleefanka-13.8/0.24/0.12...