37.5 kVA Tiirka Ku Rakiban Beddelka-2.4/0.12 kV|Kanada 2025
Awoodda: 37.5 kVA
Voltage: 2.4-0.12 / 0.24 kV
Sifada: leh off{0}} beddelka tuubada wareegga

Yaree khasaaraha, Sare u qaad wax soo saarka - Transformers-ka Tiirka Wanaagsan ee ku rakiban!
01 Guud
1.1 Sharaxaada Mashruuca
37.5 kVA hal waji oo tiir ku rakiban transformer ayaa la geeyey Kanada sanadka 2025. Awooda lagu qiimeeyay taransfooriyaha waa 37.5 kVA oo leh ONAN qaboojin. Korantada aasaasiga ah waa 2.4 kV oo leh ± 2 * 2.5% garaacista (NLTC), tamarta labaad waa 0.12 / 0.24 kV, waxay sameeyeen koox vector ah oo ah Ii6.
Midkan 37.5kVA hal - tiirka wejiga -Transformer-ka la rakibay waxaa loogu talagalay qaybinta tamarta hufan oo dabacsan ee codsiyada dibadda, muujinaysa -voltage (HV) bushing sare iyo saddex hoose -voltage (LV) bushings leh 4-dalool spade{7}} xidhid sugan oo sugan{9}} Dhanka HV waxa ay ku daraysaa xidhidh{11}}kubbada wareega wareega (± 2.5% kala duwanaanta hagaajinta), taas oo u ogolaanaysa in la xakameeyo korantada marka la tamarsiiyo, halka isku xidhka badan{14}}kubada LV uu taageerayo qaybinta culayska badan. Lagu dhisay dahaar adag iyo is haysta, tiir - qaab dhismeed la fuuli karo, cutubkani waxa uu ku habboon yahay korontada miyiga, nalalka waddooyinka, iyo - isticmaalka baaxadda leh ee warshadaha, oo bixiya khasaare hoose iyo waxqabad la isku halayn karo marka la eego xaaladaha xarkaha caadiga ah. Hawlgalka saxda ah wuxuu u baahan yahay hagaajinta tamarta tuubada iyo dayactirka joogtada ah ee baadiyaha iyo marinnada.
1.2 Tilmaamaha Farsamada
37.5 kVA tiirka ku rakiban qalabka beddelka nooca iyo xaashida xogta
|
loo geeyey
Kanada
|
|
Sannadka
2025
|
|
Nooca
Transformer ku rakiban tiirarka
|
|
Heerka
CSA C2.2-06
|
|
Awood lagu qiimeeyay
37.5 kVA
|
|
Soo noqnoqoshada
60HZ
|
|
Marxaladda
1
|
|
Polarity
Wax lagu daro
|
|
Nooca qaboojinta
ONAN
|
|
Korantada aasaasiga ah
2.4 kV
|
|
Voltage Secondary
0.12 / 0.24 kV
|
|
Qalabka dabaysha
Aluminium
|
|
barokaca xagal
II6
|
|
Caqabada
2.7%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Wax Xamuul ah ma jiro
0.078 kW
|
|
Load Lumista
0.720 kW
|
|
Waxtarka
98.73%
|
1.3 Sawirro
37.5 kVA tiirka ku dhejisan jaantuska beddelka sawirida iyo cabbirka.
![]() |
![]() |
02 Wax-soo-saarka
2.1 Core
Xudunta birta silikoon ee dhaawaca ah ee ku jirta hal - tirka wejiga{1}}ku-dhajislayaasha ku rakiban waxa ay adeegsadaan -haddii sarreen{3}} bir silikoon ku jihaysan, oo leh dhismo aan kala go 'lahayn iyo diidmo birlabeed hooseeya. Naqshadani waxay yaraynaysaa wax - khasaare rarka iyo buuqa shaqada iyadoo la gaadhayo in ka badan 98% hufnaan. - qaabdhismeedka lamination-ku wuxuu wanaajiyaa qaybinta qulqulka magnetka, taasoo ka dhigaysa mid ku habboon dalabka codsiyada qaybinta sare.

2.2 Dabaylaha

Gariiradda beddelka ee hal - tirka wejiga -Transformers-ka ee ku rakiban waxa uu ka kooban yahay lakabyo badan oo dahaaran oo fidsan/wareeg naxaas ah, oo ay ku dhexjireen qalab sare -voltage dielectric ( tusaale, Nomex ama DMD). Naqshadani waxay hubisaa xitaa daminta kulaylka, qallafsanaanta farsamada sare, iyo caabbinta wareegga gaaban oo gaaban, iyada oo la hagaajiyay awoodda is-dhex-galka waxay yaraynaysaa qallooca iswaafajinta.
2.3 Haanta
Taangiyada saliidda ee isku xiran waxay ka samaysan yihiin bir raagaya, oo loogu talagalay inay u adkeyso xaaladaha dibadda iyada oo la siinayo qaboojin waxtar leh iyo dahaarka qaybaha gudaha. Haanta waxaa ka buuxsamay saliid dahamiya oo u adeegta sida qaboojiye iyo dhexdhexaadiye dielectric labadaba. Xirmooyinka dhejinta ayaa isku dhafan si loogu rakibo tirarka tamarta.

2.4 Kulanka ugu dambeeya

1. Golaha dabaysha:U jiid dabaylaha HV/LV oo dul saar xudunta dahaarka leh, adoo hubinaya toosinta saxda ah iyo hufnaanta dahaarka.
2. Isku xirka Korontada:Isku-xidhka dabaysha waxay u horseedaa beddelka tuubada, baadiyaha, iyo qaybaha kale, ka dibna ilaali oo dahaadh kala-goysyada.
3. Xudunta - Qalajinta gariiradda:Geli qaybta firfircoon ee la soo ururiyey (core + windings) foornada qallajisa si loogu kululeeyo faakuumka si looga saaro qoyaanka.
4. Rakibaadda Haamaha:Ku rid qaybta firfircoon ee engegan taangiga, u dhig si ammaan ah, oo hubi in dahaarka saxda ah ee gidaarada haanta.
5. Kordhinta Agabka:Ku rakib bushings, valve gargaarka cadaadiska iyo qalabyada kale, ka dibna iska hubi inay jiraan.
6. Buuxinta & Dejinta Saliidda:Vacuum-ku buuxi saliid dahaarka, degsooyinka, oo oggolow degitaanka ka hor intaadan hubin heerarka saliidda iyo xoogga korontada.
03 Tijaabinta
|
Maya |
Shayga Tijaabada |
Gabagabo |
|
|
1 |
Cabbiraadaha iska caabinta |
Gudub |
![]() |
|
2 |
Imtixaanada saamiga |
Gudub |
|
|
3 |
Tijaabada polarity |
Gudub |
|
| 4 | Maya- khasaarooyinka rarida iyo xamaasadda hadda |
Gudub |
|
| 5 | Khasaaraha culeyska, korantada impedance, wadarta khasaaraha iyo hufnaanta |
Gudub |
|
| 6 | Tijaabada Korantada ee La dabaqay |
Gudub |
|
| 7 | Tijaabada adkaysiga korantada ee keentay |
Gudub |
|
| 8 | Cabbirka iska caabinta dahaarka |
Gudub |
|
| 9 | Tijaabada daadinta |
Gudub |
|
| 10 | Tijaabada Saliida | Gudub |
04 Baakaynta iyo dhoofinta
4.1 Xirxirida
Si loo hubiyo gaadiidka badbaadada leh iyo kaydinta, tiirka -ku dhejinta taranssameeyaha waxa lagu guraa sanduuqyo alwaax ah oo caado ah. Cutubka marka hore waa la nadiifiyaa oo waa la baaraa si loo xaqiijiyo in aanay jirin hadhaaga saliid ama waxyeello, iyada oo qaybo soo baxaysa (tusaale, baadiyaha, cabbiraadaha) lagu duudduubay xumbo ama duub xumbo, oo jidhka oo dhan lagu daboolay qoyaan- warqad ama filim caag ah. Ka dib waxaa lagu dhejiyaa suunka alwaax ee la xoojiyay iyadoo la isticmaalayo xargaha. Sanduuqa, oo laga dhisay alwaax dhumucdiisu tahay 15-20mm, wuxuu leeyahay xargaha gudaha si looga hortago dhaqdhaqaaqa, geeso la xoojiyey oo leh biraha birta ah, iyo dahaarka gudaha ee biyuhu. Calaamadaha sida "Jilicsan," "Ka dhig engegan," iyo "Dhinacan kor u kaca" ayaa ku lifaaqan, halka liiska baakadaha, warbixinnada tijaabada, iyo buug-gacmeedka lagu xiray bac aan biyuhu lahayn. Inta lagu jiro rarka, xargaha iyo alaabta barkinta ayaa lagu dabaqaa si looga ilaaliyo shooga inta lagu jiro safarka fogaanta{11}

4.2 dhoofinta

Marka loo eego shuruudaha CIF, tiirka{0}ku rakibay transformers waxaa loo rari doonaa dekedda Montreal. Alaab-qeybiyuhu wuxuu mas'uul ka yahay diyaarinta xamuulka badda, oo daboolaya dhammaan kharashyada ay ku jiraan caymiska iyo khidmadaha xamuulka ilaa alaabtu ka timaado dekedda ay ku socoto. Transformers waa in si amaan ah loogu xidhaa cimiladu iyo shoog{3} u adkaysta si ay ugu adkeystaan wax ka qabashada suurtagalka ah iyo xaaladaha deegaanka inta lagu jiro safarka. Dukumeenti sax ah, sida biilka rarida, qaansheegta ganacsiga, iyo shahaadada caymiska, ayaa la bixin doonaa si loo hubiyo nadiifinta kastamka Montreal.
05 Goobta iyo Kooban
Tiirka ku rakiban {{0}Transformer waa xal la isku halayn karo oo wax ku ool ah oo loogu talagalay qaybinta awooda baahsan, looguna talagalay in uu u adkaysto xaaladaha adag ee deegaanka iyada oo la hubinayo nidaaminta danab xasilan. Iyada oo dhismo adag, rakibid fudud, iyo shuruudaha dayactirka hooseeya, waa doorasho ku habboon shabakadaha tamarta, korantada miyiga, iyo codsiyada warshadaha. Oo ay taageerayaan heerarka tayada adag iyo waxqabadka la xaqiijiyay, transformers-yadayadu waxay bixiyaan - adkaysi dheer iyo hufnaan hawleed. Nala soo xidhiidh maanta si aad u hesho xalka ugu habboon ee qaybinta awoodda baahiyahaaga.

Hot Tags: 37.5 kva tiir ku rakiban transformer, saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
100 kVA Beddelka Cirifka Taleefanka-34.5/0.24 kV|USA...
167 kVA Cooper Pad Ku rakiban Beddelka-13.8/0.24 kV|...
50 kVA Hal Tiir Ku rakiban Beddelka-13.8/0.347 kV|Ka...
75 kVA Beddelka Sare-24.94/0.347 kV|Kanada 2025
50 kVA Transformer Dusha Korontada-7.97/0.12/0.24 kV...
50 kVA Transformer Utility Tiirka-13.8/0.24 kV|Guyan...
U dir sooji