25 Beddelka Tiirka Qaybinta KVA-2.4*14.4/0.12*0.24 KV|Kanada 2025
Awoodda: 25kVA
Voltage: 2.4 * 14.4-0.12 / 0.24kV
Feature: Dual-Transformer Voltage with IFD
Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha ugu kalsoonida badan 25 kva kanada 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

25kVA
01 Guud
1.1 Sharaxaada Mashruuca
Sannadkii 2025, SCOTECH waxa ay Kanada geysay 25kVA dual{2}}voltage tiir ku rakiban taransfooraha, oo si gaar ah loogu talagalay miyiga iyo kuwa hoose- shabakadaha qaybinta cufnaanta. Transformer-ku wuxuu hoos u dhigaa danab dhexdhexaad ah ilaa 120/240 V adeega deegaanka wuxuuna bixiyaa laba{7}} hawlgalka korantada, taasoo u ogolaanaysa isku xidhka dabacsan ee heerarka korantada aasaasiga ah ee kala duwan. Habkani waxa uu hubinayaa la qabsiga shuruudaha kala duwan ee utility, taas oo ka dhigaysa mid ku habboon quudiyeyaasha leh xaalado koronto oo badan. Mashruucu wuxuu raacay heerarka CSA C2.2-06 iyo shuruudaha tamarta deegaanka, iyadoo fiiro gaar ah loo leeyahay ilaalinta qalliinka, isku halaynta dahaarka, iyo badbaadada dibadda.
1.2 Qodobbada ugu muhiimsan ee Mashruuca
Labadan -Voltage 25kVA ee tirka ku rakiban isbedbedelku waxa uu isku daraa dabacsanaan, isku hallayn, iyo badbaado:
- Naqshadaynta laba-labalaha ah ee la qabsan karo- ee shabakadaha aasaasiga ah ee kala duwan
- Ilaalinta la xoojiyey ee IFD iyo xiraha qalliinka
- Duur-joogta iyo badbaadada bannaanka ee la geynayo miyiga
- Lagu dhex dhisay -guri ku yaal SCOTECH oo si buuxda u maamulaya xudunta, gariiradda, iyo samaynta haanta
1.3 Tilmaamaha Farsamada
25kVA qeexidda tiirka tiirka qaybinta iyo xaashida xogta
|
loo geeyey
Kanada
|
|
Sannadka
2025
|
|
Nooca
Transformer ku rakiban tiirarka
|
|
Heerka
CSAC2.2-06
|
|
Awood lagu qiimeeyay
25kVA
|
|
Soo noqnoqoshada
60HZ
|
|
Marxaladda
Keli
|
|
Nooca qaboojinta
ONAN
|
|
Insulant dareere ah
Saliidda Macdanta
|
|
Korantada aasaasiga ah
4160Grdy/2400X24940Grdy/14400 V
|
|
Voltage Secondary
120/240 V
|
|
Kooxda Vector
II6
|
|
Polarity
Wax lagu daro
|
|
Qalabka dabaysha
Aluminium
|
|
Caqabada
1.97%(±10%)
|
|
Waxtarka
Ka weyn ama la mid ah 98.63%
|
|
Taabo Beddelka
NLTC
|
|
Wax Xamuul ah ma jiro
83 W
|
|
Lumitaanka Korantada ee La qiimeeyay
404 W
|
|
Agabka
IFD
|
1.4 Sawirro
25kVA sawir beddelka tiirka qaybinta iyo saxanka
![]() |
![]() |
02 Wax-soo-saarka
2.1 Core

Transformer-ku waxa uu isticmaalaa xargaha birta amorphous si uu u gaadho hufnaan sare oo wax qabad la'aan la dhimo - Xuduntani waa sax{2}oo la gooyay oo lagu ururiyay aqoon iswaydaarsiyadii SCOTECH,iyaga oo siinaya khasaaraha hoose ee birta silikoonka, hagaajinta guud ahaan waxtarka tamarta,iyo hubinta waxqabadka la isku halayn karo ee cirifka miyiga{3}} codsiyada rakiban.
2.2 Qalabka Cadaadiska Relief -IFD
Aaladda Fuse Gudaha ee Ikhtiyaarka ah (IFD) ayaa loo rakibay si ay uga ilaaliso dabaylaha gudaha gaaban{0} wareegyada ama culayska xad dhaafka ah. IFD waxay si degdeg ah u dhaqantaa si ay u go'doomiso qaybta ay saamaysay iyada oo aan la joojin nidaamka intiisa kale, kor u qaadida badbaadada hawlgalka iyo isku halaynta, gaar ahaan shabakadaha qaybinta fog halkaas oo helitaanka dayactirku xadidi karo.

2.3 18KV HV xidhiha

Xadhig sare oo - 18kV ah oo wax qabad sarreeya ayaa ka ilaaliya taransfoomiyaha hillaaca iyo beddelka korontada. Halbeegyada muhiimka ah ayaa lagu doortaa iyadoo lagu salaynayo korontada transformer-ka iyo deegaanka rakibaadda miyiga. Marka lagu daro ilaalada duurjoogta, waxay ka hortagtaa waxyeelada dahaarka waxayna yaraynaysaa halista maqnaanshaha, kordhinta nolosha adeega cirifka bannaanka- rakibaadaha.
2.4 Kulanka ugu dambeeya
Transformer-ku waxa lagu ururiyay xarunta SCOTECH, oo ay ku jiraan alxanka taangiga, gacan ka-jaridda, shiididda, rasaasta{0}}qarxinta, iyo daahan budada ah. Cutub kastaa waxa uu maraa kormeer si loo hubiyo in ay soo daadato{2}ku-haynaanshaha saliida bilaashka ah, adkaysiga qaabdhismeedka, iyo iska caabinta daxalka. Isku soo wada duuboo dhammaystiran waxa uu dammaanad qaadayaa badbaado, la isku halayn karo, iyo - hawlgalka muddada dheer ee shabakadaha miyiga Kanada.

03 Tijaabinta


04 Baakadaha iyo gaadiidka
4.1 Baakad


4.2 dhoofinta


05 Goobta iyo Kooban
Loo dhisay miyi iyo mid hoose{0} shabakadaha qaybinta cufnaanta, 25 kVA dual{2}}kulka korantada ee ku rakiban transformer waxa uu hoos u dhigayaa danab dhexdhexaad ah ilaa 120/240 V, u adeega guryaha, ganacsiyada yaryar, iyo in ka badan. Nashqaddeeda laba-geesoodka ah -Naqshadeeda korantada ayaa u oggolaanaysa inay la qabsato quudiyeyaasha aasaasiga ah ee kala duwan, taasoo ka dhigaysa rakibidda dabacsan oo ka ilaalinaysa agabka tamarta mid fudud. Xidhiidhada waxtarka sare leh -, dabaylaha aluminiumka, iyo haanta saliidda xidhan ayaa ka dhigaya mid adag xaaladaha dibadda{9}} roobka, barafka, qabow, adigu magacaw. Badbaadada ayaa marka hore timaada, oo leh IFD khaladaadka gudaha ah iyo 18kV xiraha qalliinka si uu u xakameeyo hillaaca, beddelidda qulqulka, iyo xitaa duurjoogta. Sannadkii 2025, SCOTECH waxa ay gaarsiisay Kanada, si buuxda ayaa loo sameeyay oo la isugu keenay{14}}guriga, iyada oo hubinaysa in la isku hallayn karo, hooseeyo{15} hawlgalka dayactirka ee goobaha fogfog.
Hot Tags: Transformer tiirka qaybinta, saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
50 kVA Tiirka Ku Rakiban Transformers-34.5/0.48 kV|K...
100 kVA Transformer tiir Ku rakiban-13.8/0.24 kV|Guy...
75 kVA Qalabka Korontada-13.8/0.24 kV|Guyana 2025
500 kVA Tiirka Ku rakiban Badaha-24.94/0.6 kV|Kanada...
50 Kva Cirifka Ku Xidhan-25/0.347 KV|Kanada 2024
100 KVA Light Transformer-13.8/0.12*0.24 KV|USA 2025