25 Beddelka Tiirka Korontada ee KVA-7.2/0.12*0.24 KV|Kanada 2025

25 Beddelka Tiirka Korontada ee KVA-7.2/0.12*0.24 KV|Kanada 2025

Dalka la geeyey: Kanada 2025
Awoodda: 25kVA
Voltage: 7.2-0.12/0.24kV
Muuqaalka: Dual Voltage & Ilaalinta IFD
U dir sooji

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha ugu kalsoonida badan ee 25 kva transformer koronto{7}}7.2/0.12*0.24 kv|kanada 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

 

25 kVA electricity pole transformer

25 kVA Transformer tiir koronto - Awood miyiga la isku halayn karo oo leh 9kV HV Qabtaha ilaalinta qalliinka iyo badbaadada muddada dheer-

 

 

01 Guud

1.1 Sharaxaada Mashruuca

Magaalo xeebeed yar oo ku taal Atlantic Canada waxay ku tiirsan tahay khadadka qaybinta sare. Quudiyayaashu waxay ku ordaan masaafo dheer oo dhexmarta garoonnada furan iyo agagaarka xeebta. Aaggu inta badan waxa la kulma onkod xagaaga iyo dabayl xoog badan ama baraf jiilaalka. Guryaha iyo meheradaha yaryar waxay helayaan koronto hal - waji 120/240 V ah

Transformer 25 kVA waxaa loogu talagalay deegaankan. Waxay leedahay korantada aasaasiga ah ee 12,470 GRDY / 7,200 V iyo sare 120/240 V, waxay ku shaqeysaa 60 Hz, waxayna leedahay aluminium dabaysha, udub dhexaadka birta ah, qaboojinta ONAN, iyo NLTC oo leh ± 2 × 2.5% tuubada. Aad bay u hufan tahay (Ka weyn ama la mid tahay 98.87%), waxay leedahay caqabad 1.9% ± 10%, oo ay ku jirto 9 kV HV xirida ilaalinta qalliinka. Waxa loo isticmaalaa in lagu bixiyo dhawr guri ama meherad yar si badbaado leh oo la isku halleyn karo.

Bixi 3-6 guri ama meherad yar oo wadada dhinaceeda ah.

Ku dheji tiirar alwaax ah oo leh qalab caadi ah.

Ka hawlgala meelaha khatarta sare leh ee danabku ku dhoco iyo beddelidda qulqulka.

Waa maxay sababta 9kV HV ee Qabashadda muhiim u tahay? Xireeyaha 9kV waxa uu ilaaliyaa taransfooriyaha isaga oo si degdeg ah u leexinaya xadhkaha korantada ee degdega ah, sida hillaaca ama kor u wareejinta, dhulka ka hor inta aanu dahaarka waxyeelo gaadhin.

Tani waxay si gaar ah muhiim ugu tahay shabakadaha sare ee miyiga iyo xeebaha, halkaas oo hal mar oo xoog leh ay daloolin karto dahaarka, waxyeello u geysan karto dabaylaha, ama hoos u dhigto saliidda isbeddelka, taasoo horseedda guuldarro iyo go'. Qiimaynta 9 kV si taxadar leh ayaa loo doortaa si ay ugu habboonaato korantada nidaamka, iyadoo la hubinayo in xirxiruhu uu dhaqaaqo ka hor inta aan taransfooriyaha laftiisa culeyska la saarin.

 

 

 

1.2 Tilmaamaha Farsamada

25kVA tafatirka tiirka korantada iyo xaashida xogta

loo geeyey
Kanada
Sannadka
2025
Nooca
Transformer ku rakiban tiirarka
Heerka
CSA C2.2-06/C802.1-23
Awood lagu qiimeeyay
25KVA
Soo noqnoqoshada
60HZ
Marxaladda
Keli
Nooca qaboojinta
ONAN
Insulant dareere ah
Saliidda Macdanta
Korantada aasaasiga ah
12470GRDY/7200
Voltage Secondary
120/240 V
Polarity
Wax lagu daro
Kooxda Vector
II6
Qalabka dabaysha
Aluminium
Caqabada
1,9%(±10%)
Waxtarka
Ka weyn ama la mid ah 98.87%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
85 W
Lumitaanka Korantada ee La qiimeeyay
254 W
Agabka
9kV HV

 

1.3 Sawirro

25kVA sawir beddelka tiirka korantada iyo warqad magaceed

25kVA electricity pole transformer drawing 25kVA electricity pole transformer nameplate

 

 

02 Wax-soo-saarka

2.1 Core

25kVA electricity pole transformer iron core

Transformer-ku waxa uu leeyahay xudunta boogta oo ka samaysan bir dhuuban. Waxay ka caawisaa tamarta birlabku inay si fudud u dhex marto dabaylaha aasaasiga ah iyo kan sare, iyadoo yaraynaysa khasaaraha tamarta. Xuddunta waa xoog badan tahay oo is haysta, korantada ilaalinaysa, hoos u dhigaysa kulaylka iyo qaylada, iyo samaynta transformer-ka la isku halayn karo maalin kasta.

 

2.2 Dabaylaha

Loogu talagalay waxqabad joogto ah, Transformer-kani waxa uu ku lammaaniyaa foil LV oo leh silig HV. Copper waxay qaadataa hadda, aluminiumku wuu fududeeyaa miisaanka. Way wada shaqeeyaan. Joogitaanka kulaylku waa la maareeyaa. Khasaaruhu wuu hooseeyaa. Xamuulku wuu is beddelaa, cimiladu way beddeshaa, laakiin wuu sii socdaa. Fudud, wax ku ool ah, shaqaale aamusan oo tiirka ku jira -qaybinta dulsaaran

25kVA electricity pole transformer coils

 

2.3 9KV HV xidhiha

25kVA electricity pole transformer HV arrester

Xadhigaheeda 9kV HV, ee ku xidhan kaynta HV ilaa dhulka, waxay ilaalisaa transformer-ka iyadoo si degdeg ah u leexinaysa hillaaca ama wareejinta qulqulka ka hor intaan dahaarka ama dabayshu aanay waxyeelo gaarin. Iyada oo koronto joogto ah oo shaqaynaysa oo ah 7.65 kV iyo danab hadhaaga ah oo ka hooseeya 30 kV, waxay la mid tahay tamarta nidaamka iyadoo la tacaalayo qulqulka ilaa 100 kA. Dheecaan qayb yar oo hooseeya (<10 pC) and 308 mm creepage distance ensure safe, reliable operation in wet or coastal conditions.

 

2.4 Kulanka ugu dambeeya

Kadib marka aan dhigno xudunta iyo gariiradaha taangiga birta ah ee xidhan, unuga oo dhan waxa uu maraa alxanka taxadar leh iyo daawaynta adag ee ka hortagga- si ay u xamili karto sanadaha bannaanka, cimilada xeebaha. Kahor iyo ka dib buuxinta saliidda macdanta, waxaanu wadnaa faakuum buuxa{2}} habka qalajinta si aanu u saarno qoyaan kasta ama hawo xayiran-tallaabadani runtii waxay xoojisaa dahaarka waxayna hoos u dhigtaa dheecaanka qayb ahaan. Iyada oo haanta buuxsantay iyo nidaamkeeda qaboojinta ee ONAN oo diyaar ah, transformerku waxa uu ka soo baxaa shirkii u dambeeyay ee loo dhisay tiir dheer oo la isku halayn karo-

electricity pole transformer active part

 

 

03 Tijaabinta

25 kVA electricity pole transformer testing-1
25 kVA electricity pole transformer testing-2

 

 

04 Baakadaha iyo gaadiidka

4.1 Baakad

25 kVA electricity pole transformer packing-1
25 kVA electricity pole transformer packing-2

 

4.2 dhoofinta

25 kVA electricity pole transformer shipping-1
25 kVA electricity pole transformer shipping-2

 

 

05 Beddelka Cirifka Korontada: Siday U Shaqeeyaan

Electricity Pole Transformer

Tiirka -Transformer-ka ku rakiban waxa uu isticmaalaa kicinta korantada si uu hoos ugu dego{1}koronta Voltage ilaa heer ku haboon guryaha iyo ganacsiyada yaryar. Gudaha, waxa ay leedahay laba dabaylo -primary and secondary-oo lagu duuduubay xudunta birlabeedka:
Dabaylaha aasaasiga ahi waxa uu ku xidhaa shabakada qaybinta korantada sare -
Dabaysha labaad waxay ku xidhaa khadadka adeega voltajiga hoose ee keena 120 V ama 240 V dhismayaasha.
Korontadu waa la dhimay iyadoo loo eegayo saamiga leexashada ee u dhexeeya dabaylaha aasaasiga ah iyo kan sare, iyadoo siinaya badbaado, koronto la isticmaali karo aaladaha maalinlaha ah.

 

 

Hot Tags: Transformer tiirka korontada, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha