25kva Tiirka Ku rakiban Beddelka-2.4*7.2/0.12*0.24 KV|Kanada 2025

25kva Tiirka Ku rakiban Beddelka-2.4*7.2/0.12*0.24 KV|Kanada 2025

Dalka la geeyey: Kanada 2025
Awoodda: 25kVA
Voltage: 2.4 * 7.2-0.12 / 0.24kV
Feature: Dual-Transformer Voltage with IFD
U dir sooji

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soo saarayaasha ugu kalsoonaan karo iyo alaab-qeybiyeyaasha 25kva tiirka ku rakiban transformer{8}2.4*7.2/0.12*0.24 kv|kanada 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

 

25kva pole mounted transformer

25kVA tiirka ku rakiban transformer - dual-voltage leh IFD, looguna habeeyey la isku halayn karo, badbaado, iyo dheer{3}} qaybinta awooda miyiga waarta

 

 

01 Guud

1.1 Sharaxaada Mashruuca

Sannadkii 2025, SCOTECH waxay bixisay 25kVA hal - tiir weji ah oo ku rakiban taransfooraha mashruuca qaybinta tamarta Kanadiyaanka.

Mashruucu wuxuu raacay CSA C2.2 -06 heerarka iyo shuruudaha utility Canadian maxaliga ah. Waxaan fiiro gaar ah siinay ilaalinta qalliinka, isku halaynta dahaarka, iyo badbaadada bannaanka-sababtoo ah meelaha miyiga ah, ma ogid waxa cimilada ama duur-joogta ay kugu soo tuurayaan.

Ku rakiban tiirka qaybinta ee ku teedsan khadka quudiyaha miyiga ah, transformer-kan ayaa hoos u dhigaya danab dhexdhexaad ah ilaa 120/240 V ee adeegga deegaanka. Waxa si gaar ah loogu dhisay shabakadaha qaybinta sare ee meelaha hoose{3}}cufnaanta, halkaas oo danab deggan iyo adkaysiga deegaanku ay muhiim u yihiin-iyo haa, ilaalinta duurjoogta sidoo kale.

Mar haddii tiirarkani ay soo gaadhaan hillaac, beddelaad badan, iyo mararka qaarkood xayawaanka xiisaha leh, waxaanu ku qalabaynay cutubka -waxqabad sare oo soo xidha iyo ilaalin duurjoogta ah. Qalabayntani waxay ilaalinaysaa transformer-ka la isku halayn karo muddada dheer waxayna kaa caawinaysaa yaraynta khatarta maqnaanshaha, xitaa xaaladaha adag.

 

 

 

1.2 Tilmaamaha Farsamada

25kVA tiirka ku rakiban tafatirka tafatirka iyo xaashida xogta

loo geeyey
Kanada
Sannadka
2025
Nooca
Transformer ku rakiban tiirarka
Heerka
CSA C2.2-06
Awood lagu qiimeeyay
25KVA
Soo noqnoqoshada
60HZ
Marxaladda
Keli
Nooca qaboojinta
ONAN
Insulant dareere ah
Saliidda Macdanta
Korantada aasaasiga ah
2.4 * 7.2-0.12 / 0.24kV
Voltage Secondary
120/240 V
Kooxda Vector
II6
Qalabka dabaysha
Aluminium
Caqabada
2.02%(±10%)
Waxtarka
Ka weyn ama la mid ah 98.63%
Taabo Beddelka
NLTC
Wax Xamuul ah ma jiro
104 W
Lumitaanka Korantada ee La qiimeeyay
309 W
Agabka
Laba{0}}Transformer-ka korantada ee leh IFD

 

1.3 Sawirro

25 kVA tiir ku rakiban sawir beddelka iyo saxanka magaca

25kva pole mounted transformer drawing 25kva pole mounted transformer nameplate

 

 

02 Wax-soo-saarka

2.1 Dabaylaha

25kva pole mounted transformer winding

Habaynta gariiradda: foornada LV, silig HV, isku dhafka naxaasta iyo aluminium. Foolku wuxuu fidiyaa hadda, wuxuu daadiyaa kulaylka. Siliggu wuu qalloocan yahay, wuu go'ay. Copper - Isku darka aluminiumku wuxuu haleelaa waxtarka iyo qiimaha saxda ah. Waara Waxay ka shaqeysaa waddooyinka magaalooyinka, khadadka miyiga, wax kasta oo maalintu ku soo tuurto. Lagu kalsoonaan karo, deggan, shaqadeeda qabsanaysa buuq la'aan.

 

2.2 IFD

Tiirkan 25kVA ee ku rakiban transformer-ka waxa uu ku qalabaysan yahay Aaladda Fuuska Gudaha ee Ikhtiyaarka ah (IFD), oo loo doortay si ay u bixiso ilaalin dheeraad ah oo loogu talagalay dabaylaha beddelka. IFD waxay u shaqeysaa sidii ilaalin ka hortag ah gudaha gaaban -wareegyada ama culeysyada xad dhaafka ah, waxay jaraysaa qaybta dabaysha ee ay saamaysay iyada oo aan saamayn ku yeelanayn nidaamka intiisa kale. Habkani waxa uu kor u qaadayaa isku halaynta shaqada, gaar ahaan shabakadaha qaybinta ee fog ama miyiga, waxaana loo doortay mashruucan si uu u buuxiyo badbaadada gaarka ah ee macaamilka iyo shuruudaha waxqabadka.

25kva pole mounted transformer IFD

 

2.3 Haanta

25kva pole mounted transformer tank

Haanta saliidda waxaa lagu soo saaray aqoon-is-weydaarsiga taangiyada ee SCOTECH iyadoo la raacayo hab-soo-saar sax ah: taarikada birta ayaa markii hore la gooyay cabbir ahaan, la qoday, la foorarsaday, oo qaab ahaan loo rogay, ka dibna lagu alxanay haan dhamaystiran. Alxanka ka dib, farsamayaqaanadeena xirfada leh ayaa gacantooda ka saaray slag, sida ka muuqata sawirka la socda, taangigana waxaa lagu sii diyaariyay shiidid iyo toogasho -qarax. Ugu dambayntii, daahan budo ah ayaa la mariyay, taangiga la dhammeeyayna waxa lagu maray kormeer dhammaystiran si loo hubiyo cimri dhererka dibadda-, iska caabinta daxalka, iyo tayada guud.

 

2.4 9KV HV xidhiha

Si loo ilaaliyo tiirka 25kVA ee ku rakiban transformer-ka ku shaqeeya nidaamka qaybinta aasaasiga ah ee 7.2kV, xidhiyaal qalliin oo heerkiisu yahay 9kV ayaa la doortay oo lagu rakibay dhinaca hore.

Xidhuhu waxa uu hillaaca hillaaca ku hayaa in ka hooseeya 30 kV, taas oo macnaheedu yahay in dahaarka taransfooriyuhu uu ahaado mid la ilaaliyo oo nolosheeda adeeg waxa ay helaysaa kor u kac dhab ah{1}}gaar ahaan waxa ka soo baxa tiirarka bannaanka ah ee duufaanadu si adag u garaaci karaan.

Iyo sababta oo ah rakibaadahani waa bannaanka, iyo xayawaanku- si fiican ayey u xiiseeyaan{1}}waxa aanu ku darnay ilaalada duurjoogta duurjoogta iyo xidhaha laftiisa. Sidan, halista xawayaanka{3}}ciladaha la xidhiidha ayaa hoos u dhaca, transformer-ku wuxuu ahaanayaa mid badbaado leh oo la isku halayn karo. Dhab ahaan waa nooca ilaalinta aad uga baahan tahay shabakadaha qaybinta miyi iyo agagaaraha.

Surge Arresters Installed on Transformers
Qab-qablayaasha Qalalaasaha ah ayaa lagu rakibay Transformers
Surge Arrester Drawing
Sawir-qaadista Qab-qabashada Sare
Surge Arrester Protective Cover
Daboolka Ka-hortagga Qab-qabashada Sare

 

 

03 Heerka Qaab-dhismeedka Qaybinta

25kVA pole mounted transformer distribution Structure Standard

 

Shayga

Sharaxaada

Tirada

1

Goynta, Nasashada Xamuulka

1

2

Fuse

1

3

Qalab, Polymer, 18 kV, 15.3 kV MCOV (Xajmiga Korantada Koowaad)

1

4

Beddelka (Xajmiga iyo Qiimaynta lagu cayimay Qorshaha Goobta)

1

5

Isku dheji, Kicin, # 6 ilaa 3/0

1

6

Isku dheji, khadka kulul, # 8 ilaa 2/0

1

7

Xidhiidhiyaha, Cadaadiska, H-Taabo, #2-6 ACSR ilaa #1-6 STR

3

8

Garaashka, Goynta, Alxanka, Tiirka -Ku rakiban, Dhererka 12"

1

9

Fiilada/Siliga, Liidashada Liidhyada

9

10

Cable, # 2, Copper Xarigaysan, Madow, RW90

9

11

Cable, # 2, Copper Xarigaysan, Cagaaran, RW90

3

12

Bracket, Taangiga {{0}Qiqaabta Rakaabka ah, 2-1/4" Kamid ah, 7-1/2" Dhererka

1

13

Ilaalinta Duurjoogta, Transformer Bushing

1

 

Bolt, Mishiin, 3/4 "Dia. (Dharka sida Loo Baahan yahay), c/w Square Nut

Sida Loo Baahan Yahay

 

Maydhista, Quful, 3/4 "Nom., Helical Spring, Galv. CSAG164M

Sida Loo Baahan Yahay

 

Washtarka, Square, Flat, 3/4" Nom.

Sida Loo Baahan Yahay

 

Bolt, Lag, 1/2 "Dia., 4-1/2" Dhererka

1

 

04 Baakadaha iyo gaadiidka

4.1 Baakad

25kVA pole mounted transformer packing-1
25kVA pole mounted transformer packing-2

 

4.2 dhoofinta

25kVA pole mounted transformer shipping-1
25kVA pole mounted transformer shipping-1

 

Hot Tags: 25kva tiir ku rakiban transformer, saaraha, alaab-qeybiyaha, qiimaha, qiimaha

U dir sooji