50kva pole mounted transformer

50kVA tiir ku rakiban transformer - Dual Voltage & IFD, oo loo dhisay qaybinta Kanada ee la isku halayn karo

 

 

01 Guud

1.1 Sharaxaada Mashruuca

Midkan 50kVA ee hal -Tiirka wejiga{2}}dhajinaya taransfooriyaha wuxuu keenaa awood badbaado leh oo la isku halayn karo guryaha iyo ganacsiyada yaryar. Waxay ku dul rakiban tahay tiirarka utility waxayna hoos u dhigtaa -korontada korantada ee shabakada qaybinta (12,470 GRDY/7,200 V) ilaa heerka 120/240 V ee nidaamka Waqooyiga Ameerika 60 Hz.

Transformer-ku waxa uu leeyahay udub dhexaadka birta ah ee dahaaran kaas oo si hufan ugu gudbiya tamarta inta u dhaxaysa dabaylaha hoose iyo kan sare. Dabayshu waxay ka samaysan tahay aluminium tayo sare leh{1} waxayna si buuxda u dahaaran yihiin si ay u xakameeyaan culayska korontada. Unuggu waxa ay gaadhaan hufnaan sare (Ka weyn ama la mid ah 99.04%) iyada oo aan lahayn - lumin 130 W iyo luminta culayska 492 W, oo waxay sifaysaa 2.15% impedance (± 10%) ee nidaaminta korantada joogtada ah ee culayska saaran. Aan {{10}Qorashka Taabka Beddelka ah (NLTC) ee leh ±2×2.5% kala duwanaanta tuubada waxa ay ogolaataa hagaajinta danab fiican. Isku-dhafka Ciladda Gudaha (IFD) ayaa kala socota kororka arrimaha gudaha. Xiriyaha korantada ee 9kV oo sarreeya{16} wuxuu ka ilaaliyaa kor u kaca Transformer-ku wuxuu isticmaalaa qaboojinta ONAN iyo dahaarka saliidda macdanta si loo hubiyo isku halaynta muddada dheer{18} dibadda

Transformer-kani waxa uu ku habboon yahay xaafadaha la deggan yahay, beeraha, iyo tas-hiilaadka yar yar ee ganacsiga. Waxay si fiican ugu shaqeysaa shabakadaha qaybinta miyiga iyo xaafadaha, fidinta shabakada, iyo dejinta awooda ku meel gaarka ah. Haanta xidhan iyo naqshadeeda adag ayaa ka dhigaysa mid la isku halayn karo marka lagu jiro xaaladaha adag ee dibadda sida barafka, roobka, iyo heerkulka xad dhaafka ah.

 

 

 

1.2 Tilmaamaha Farsamada

50kVA tiirka ku rakiban tafatirka tafatirka iyo xaashida xogta

loo geeyey
Kanada
Sannadka
2025
Nooca
Transformer ku rakiban tiirarka
Heerka
CSAC2.2-06/C802.1-23
Awood lagu qiimeeyay
50KVA
Soo noqnoqoshada
60HZ
Marxaladda
Keli
Nooca qaboojinta
ONAN
Insulant dareere ah
Saliidda Macdanta
Korantada aasaasiga ah
12470GRDY/7200 V
Voltage Secondary
120/ 240 V
Kooxda Vector
II6
Polarity
Wax lagu daro
Qalabka dabaysha
Aluminium
Caqabada
2.15%(±10%)
Waxtarka
Ka weyn ama la mid ah 99.04%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
130 W
Load Lumista
492 W
Agabka
9kV HV

 

1.3 Sawirro

50kVA tiir ku rakiban is beddelka sawirista iyo saxanka magaca

50kva pole mounted transformer drawing 50kva pole mounted transformer nameplate

 

 

02 Wax-soo-saarka

2.1 Core

50kva pole mounted transformer iron core

Tirka ku jira {{0}Transformers ee rakiban, xudunta ayaa sidoo kale loo dhisay inay noqoto mid is haysta oo gariirka{1}} u adkaysata si ay si badbaado leh ugu fadhiisato tiirarka tamarta. Waxay u taagan tahay dabaysha, barafka, iyo xaaladaha kale ee bannaanka, iyadoo la ilaalinayo - khasaaraha rarka hoose - taasoo fure u ah khadadka dhaadheer ee quudinta guryaha iyo ganacsiyada yaryar.

 

2.2 Dabaylaha

50kva pole mounted transformer coil
50kva pole mounted transformer copper coil

Gariiradayada waxaa sameeya kooxo khibrad leh oo raacaya habraac cad. Shaqaaluhu waxay si adag ugu dhejiyaan gariiradaha LV iyo naxaasta dabaysha si siman oo loogu talagalay gariiradaha HV. Kormeerayaashu waxay la socdaan talaabooyinka waxayna saxeexaan imtixaanada ugu dambeeya. Isku dhafkan farsamada gacanta, hubinta, iyo wada shaqaynta kooxeed ayaa ka dhigaysa transformers-yada la isku halayn karo marka ay jiraan xaalado adag oo gudaha ah.

 

2.3 Haanta

Transformer-ku waxa uu isticmaalaa haanta saliidda xidhan {{0}si buuxda u xidhan, cadaadis{1}} adag, oo lagu dhisay dhismo alxan leh. Daloolo ma leh, ma laha tolmo jilicsan. Alxanka ka dib, taanggu waxa uu maraa vacuum ama hawo-tijaabooyin cidhiidhi Nadaamka dahaarka waa banaanka-darajada: epoxy primer oo lagu daray polyurethane dhame, oo leh dhamaan daxalka qalabka- la ilaaliyo. Terminalku waxay raacaan jaantusyada caadiga ah, waxaana boos loo hayaa xidhiyaasha iyo dhibcaha dhulka iyada oo aan wax saamayn ah ku yeelan xoogga qaadista ama xaglaha korka. Ku fiican cimilo qallafsan iyo adeeg dheer.

50kva pole mounted transformer oil tank

 

 

03 Baakadaha iyo gaadiidka

3.1 Baakad

50kva pole mounted transformer waiting for packing
50kva pole mounted transformer packing

 

 

4.2 dhoofinta

50kva pole mounted transformer shipping-1
50kva pole mounted transformer shipping-2

 

 

04 Rakibaadda

Rakibaadda Tiirarka -Transformer-ka Rakiban
Diyaarinta Goobta

Dooro meel ku haboon taransfooriyaha. Dhulku waa inuu ahaado mid xasiloon oo la heli karo, goobtuna waa inay u dhowdahay xadhkaha korontada ee jira. Ka saar wixii dhagxaan ah, dhir, ama xannibaadyada aagga.
Kormeerka Cirifka
Kormeer tiirka tamarta ka hor inta aan la rakibin. Hubi in uu qaabdhismeedkiisu yahay mid sanqadhsan, oo ka madax bannaan dildilaaca ama qudhunka, oo awood u leh inuu si badbaado leh u taageero miisaanka beddelka.
Kormeerka Transformer
Ka baadh transformerka wixii calaamado ah ee waxyeelo ah Hubi duurka, terminaalka, iyo qaybaha qaboojinta si aad u xaqiijiso inay nadiif yihiin oo ay xaalad fiican ku sugan yihiin.
Ku rakibida Transformer-ka
Isticmaal wiish ama kor u qaad si aad kor ugu qaaddo beddelka booska. Si adag ugu xidh tiirka biraha iyo xidhmooyinka korka. Hubi inay siman tahay oo xasiloon tahay.
Isku xirka Korontada
Ku xidh -voltajka sare iyo kan hoose{1} Hubi in dhammaan terminalku nadiif yihiin, cidhiidhi yihiin, oo si habboon u siman yihiin.
Dejinta
Ku xidh kaariyaha dhulka ee usha dhulka ee la ansixiyay ama nidaamka dhulka. Tani waxay ka hortagtaa cilladaha korantada waxayna hagaajinaysaa isku halaynta nidaamka.
Tijaabinta
Rakibaadda ka dib, samee tijaabooyin koronto oo caadi ah sida caabbinta dahaarka, polarity, iyo hubinta korantada. Xaqiiji in tamar-malaha uu si sax ah u shaqeeyo ka hor intaadan tamar gelin.

Kormeerkii U Danbeeyay
Kormeeraha ama injineerku waa inuu sameeyaa dib u eegis kama dambays ah. Ka hadal wixii arrimo ah ama dib-u-habayn kasta marka loo baahdo si loo buuxiyo amniga iyo heerarka tayada.
Dukumeenti
Diiwaangeli dhammaan natiijooyinka imtixaanka, faahfaahinta qalabka, iyo qoraallada rakibidda. Hayso dukumeentiyadan dayactirka iyo tixraaca mustaqbalka.
50kva pole mounted transformer waiting for testing

 