50 KVA Transformers-14.4/0.12*0.24 KV|Kanada 2025
Awoodda: 50kVA
Voltage: 14.4-0.12/0.24kV
Muuqaalka: Dual Voltage & Ilaalinta IFD
Jiangshan Scotech Electric Company kanada 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

50 kVA tiirka tiirarka leh Dual Voltage & IFD ilaalinta - hufan, sare u kac{2}}awood diyaar u ah shabakadaha qaybinta xeebaha iyo miyiga
01 Guud
1.1 Sharaxaada Mashruuca
50 kVA hal -Tiirka wejiga{2}}ku dhejiyay taransfooriyaha waxaa loogu talagalay qaybinta sare ee lagu kalsoonaan karo ee xeebaha iyo miyiga. Waxay ku shaqeysaa 60 Hz waxayna taageertaa laba voltages aasaasiga ah (24,940 GRDY ama 14,400 V), taas oo u oggolaanaysa in lagu rakibo quudiyeyaal kala duwan iyadoo la bixinayo 120/240 V soosaarka sare. Cutubku waxa uu isticmaalaa dabaylaha aluminiumka ah iyo xudunta birta dahaadhay, oo leh ONAN qaboojin iyo macdan{12}}saliid ku jira haanta xidhan ee nolosha dibadda dheer. Waxay gaadhaa wax ka badan ama la mid ah 99.04% hufnaan, iyada oo aan lahayn - lumitaanka 130 W, luminta rarka 492 W, iyo caqabada 2.16% (± 10%). Aan {{21}Qorashka Taabo Bedelka (NLTC) ±2 × 2.5% waxa uu ilaaliyaa korantada marka la beddelo culaysyada.
Transformer-ku waxa kale oo uu sido 9kV sare -voltage xidhe si uu u xidho hillaaca oo uu u beddelo qulqulka dhulka ka hor inta aanay culaysin dahaarka ama waxyeelaynta dabaylaha - waa qasab quudiyayaal soo gaadhay duufaanta, buufinta milixda, iyo dabaysha jiilaalka. Qaabka laba-geesoodka ah -Sifada korantada waxa ay u ogolaataa utility-yada in ay kaydka ku hayaan noocyo kayar oo taransfoorayaasha oo ay si deg deg ah u rakibaan cutubyada marka ay maqan yihiin ama casriyaynta Iyadoo lagu qiimeeyo 50 kVA, waxay u adeegi kartaa guryo iyo ganacsiyo ka badan 25 kVA transformer, taasoo ka dhigaysa mid la isku halayn karo, oo hooseeya-xaalka dayactirka ee shabakadaha qaybinta xeebaha iyo miyiga.
1.2 Tilmaamaha Farsamada
50kVA tiirka tiirka qeexidda iyo xaashida xogta
|
loo geeyey
Kanada
|
|
Sannadka
2025
|
|
Nooca
Transformer ku rakiban tiirarka
|
|
Heerka
CSA C2.2-06/C802.1-23
|
|
Awood lagu qiimeeyay
50KVA
|
|
Soo noqnoqoshada
60HZ
|
|
Marxaladda
Keli
|
|
Nooca qaboojinta
ONAN
|
|
Insulant dareere ah
Saliidda Macdanta
|
|
Korantada aasaasiga ah
24940GRDY/14400 V
|
|
Voltage Secondary
120 / 240 V
|
|
Kooxda Vector
II6
|
|
Polarity
Wax lagu daro
|
|
Qalabka dabaysha
Aluminium
|
|
Caqabada
2.16%(±10%)
|
|
Waxtarka
Ka weyn ama la mid ah 99.04%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Wax Xamuul ah ma jiro
130 W
|
|
Lumitaanka Korantada ee La qiimeeyay
492 W
|
|
Agabka
9kV HV
|
1.3 Sawirro
50kVA Transformers tiirarka sawirida iyo saxarada
![]() |
![]() |
Naqshad la Habeeyay ee Xaaladaha Cimilada Xeebta
Maadaama goobta la rakibay ay ku taallo aag xeebeed{0}} leh hawo qoyan, roob badan, iyo xoogaa milix ah oo hawada ku jirta{1}}waxa aanu ka gudubnay habayn aasaasi ah oo aanu samaynay dhawr horumarin oo la beegsaday:
1. Sare - Daboolida Ilaalinta Dhirta Voltage
Waanu horay u sii soconay oo waxaanu saarnay daboolo ilaalin ah -kaynta korantada- badiba si aanu u ilaalino dahaarka mid faraxsan oo xasiloon. Waad ogtahay, meel qoyan, roob da'aya, mararka qaarkood jawi qoyan oo cad, dahaarka daboolan ayaa ah nooca weydiinaya dhibaato. Dabooladaasi? Asal ahaan waxay ka ilaalinayaan qoyaanka, hawada xeebta leh ee cusbada leh, dhammaan waxyaabaha yaryar ee nolosha ku adkeyn kara beddelka.


2. 9 KV HV-xidhaha
Kadibna waxaa jira xiraha 9kV HV. Wax yar, haa, laakiin waa heshiis weyn marka xadhkaha korantada ee yaabka leh ay ku dhuftaan - duufaano, beddelaad, ama kaliya khalkhal abuurka cimilada xeebaha. Waa halkaas si aad u qabato, joojiso wax-soo-baxyada, oo asal ahaan ka ilaali nidaamka in uu ka naxo maalin xun.

02 Wax-soo-saarka
2.1 Core

Xudunta dhaawaca waxaa loo sameeyay isticmaalka dibadda. Nashqaddeeda is dulsaaran ayaa iska caabineysa gariir waxayna ku ilaalisaa transformer-ka mid ku taagan tiirarka. Waxay yaraynaysaa khasaaraha -, si fiican ayay uga shaqaysaa quudiyeyaasha dhaadheer, waxayna xamili kartaa dabaysha, barafka, iyo cimilada kale, iyadoo siinaya guryaha iyo ganacsiyada yaryar koronto la isku halayn karo.
2.2 Dabaylaha


Tiirkan -Transformer-ka rakiban waxa uu isticmaalaa dabaylaha foil hooseeya -iyo fiilo sare oo fiil ah, naxaas iyo aluminium oo la isku daray. Foil-ka LV ayaa hoos u dhigaya xannibaadda. Kulaylku si siman buu u faafaa. Siliga HV waa dabacsan yahay, wuxuu qabtaa isbeddellada culeyska. Copper -isku darka aluminiumka{8}}wuxuu dheelitiraa waxtarka iyo qiimaha Lagu kalsoonaan karo, waara, ku habboon shabagyo yaryar, ganacsi la deggan yahay ama iftiin, maalinba maalinta ka dambaysa.
03 Tijaabinta


04 Baakadaha iyo gaadiidka
4.1 Baakad


4.2 dhoofinta


05 FAQ

S1: Ma badbaado tahay in transformer-ka lagu rakibo meelaha qoyan ama xeebaha ah?
Q2: Transformer ma kulaylka badan karaa?
S3: Ma loo baahan yahay hillaaca xidhaa?
Q4: Immisa jeer ayaa loo baahan yahay in transformer-ka la dayactiro?
Hot Tags: Transformers tirka, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
50 kVA Tiirka Ku Rakiban Transformers-34.5/0.48 kV|K...
75 kVA Transformer ee Xadhkaha Korontada-12.4*24.94/...
100 kVA Cirifka Buurta Beddelka-24.94 / 0.347 kV|Kan...
50 KVA Tiirka Ku Rakiban Tamashlaha 3 Wajiga-2.4/0.6...
25 KVA Hal Waji Beddelka Cirifka-25/0.347 KV|Kanada ...
25kva Tiirka Ku rakiban Beddelka-2.4*7.2/0.12*0.24 K...
U dir sooji