100kva Cirifka Ku rakiban Badal-13.8/0.347 KV|Kanada 2026

100kva Cirifka Ku rakiban Badal-13.8/0.347 KV|Kanada 2026

Dalka: Kanada 2026
Awoodda: 100 kVA
Voltage: 13.8/0.347 kV
Feature: oo leh xire qalliin
U dir sooji

Jiangshan Scotech Electrical Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha 100kva ugu kalsoonida badan kanada 2026 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. nala soo xidhiidh wixii faahfaahin ah

 

image001

Laga soo bilaabo koronto-siinta miyiga ilaa cusboonaysiinta magaalooyinka, tiirarka korontadu waxay horumariyaan meel kasta.

 

 

01 Guud

1.1 Sharaxaada Mashruuca

100 kVA hal waji oo tiir ku rakiban transformer ayaa la geeyey Kanada 2025. Awoodda la qiimeeyay ee transformerku waa 100 kVA oo leh ONAN qaboojin. Korantada sare waa 13.8 kV oo leh ± 2 * 2.5% garaacista (NLTC), korantada hoose waa 0.347 kV, waxay sameeyeen koox vector ah Ii6.

Mashruucani waa amar ku celis toos ah oo ka yimid macaamiisha tamarta Kanada, iyadoo la raacayo gudbinta guusha leh iyo hawlgalka goobta ee dufcad isku mid ah horraantii 2025. Qaybaha bilawga ah waxay si kalsooni leh ugu shaqeeyeen shabakadaha sare ee miyiga iyo agagaarkeeda muddo ka badan wareeg xilliyeedka oo buuxa, heerkul aad u sarreeya oo u dhexeeya -40 darajo ilaa +40 darajo oo koronto la xidhiidha{5} Jawaab celinta goobta ayaa la xaqiijiyay in ay sare u kacday{6}}kulka saliida ayaa si fiican ugu sii jiraya xadka 65 digrii ee CSA-gu waajibisay, iyo waxtarka la qiyaasay ee 99.04% waxa la keenay kaydka tamarta la taaban karo ee sanadka 2025.

Dalabka soo noqnoqda waxa uu taageerayaa barnaamijka ballaadhinta xariiqda 2026 ee macmiilka, iyada oo la beegsanayo hal - wajiga fidsan ee laynka dambe ee koraya kooxaha degaanka, beeraha, iyo hoyga isgaadhsiinta ee gobolka Ontario iyo galbeedka. Cutub kasta waxaa lagu qiimeeyay 100 kVA, 13.8/0.347 kV, oo leh kooxda Ii6 vector, polarity additive, iyo ±2×2.5% off - beddelka tuubada wareega{10}heerka qaabeynta dhaqanka qaybinta Waqooyiga Ameerika. U hoggaansanaanta CSA C2.2-06 (R2022) iyo hufnaanta CSA C802.1-13 (R2022) waxay u qalantaa beddelaadaha barnaamijyada dhiirigelinta tamarta ee gobolka.

Marka la eego dhulka adeegga macaamiisha ay la kulmaan dhaq-dhaqaaqa duufaanta sare, qeexitaanku wuxuu si cad u amrayaa ilaalinta sare. SCOTECH waxay midaysaa YH10W -12/40 TL birta{5}} xidh xidhaha oksaydhka sidii warshad ahaan{6}}sifada rakiban{{7}oo ay ansixisay dufcaddii hore ee eber hillaaca-ay keentay guul darooyinka 2025 oo dhan. jidadka sare ee bannaanka ah.

 

 

 

1.2 Tilmaamaha Farsamada

100 kVA tiirka ku rakiban qalabka beddelka nooca iyo xaashida xogta

loo geeyey
Guyana
Sannadka
2025
Nooca
Transformer ku rakiban tiirarka
Heerka
CSA C2.2-06
Awood lagu qiimeeyay
100 kVA
Soo noqnoqda
60HZ
Marxaladda
1
Polarity
Wax lagu daro
Nooca qaboojinta
ONAN
Korantada aasaasiga ah
13.8 kV
Voltage Secondary
0.347 kV
Qalabka dabaysha
Copper
barokaca xagal
ii6
Caqabada
3.0%
Taabo Beddelka
±2*2.5%
Wax Xamuul ah ma jiro
0.192 kW
Load Lumista
1.52 kW
Waxtarka
98.94%
Midabka
cawl khafiif ah, Number 70, Munsell note 5BG7.0/0.4

 

1.3 Sawirro

100 kVA tiir ku rakiban jaantuska beddelka sawirka iyo cabbirka.

image003 image005

 

 

02 Wax-soo-saarka

2.1 Core

image007

Wareegga birlabeedka waxa laga dhisay -permeability, hadhuudh - bir silikoon ku jihaysan oo si sax ah loo xidho si loo yareeyo khasaaraha hadda jira iyo xiiqsanaanta. Laguma qiyaaso - khasaaraha rarka ee 100% la qiimeeyay danabku waa 160 W, si fiican uga hoosaysa qiimaha dammaanad qaaday ee 192 W. Marka la eego 105% danab lagu qiimeeyay, maya{9}}luminta rarka waa 190 W

 

2.2 Dabaylaha

Labada sare -voltage iyo hoose- dabaylaha danabku waxa ay dhaawacaan naxaasta korantada, iyaga oo keenaya hab-dhaqan aad u wanaagsan iyo xoog makaanik ah oo ka dhan ah{2}} xoogag wareeg ah. Nidaamka dabaysha ee xoogga leh ee leh tuubooyinka saliidda ee la farsameeyay waxay kor u qaaddaa wareegga saliidda dabiiciga ah ee daadinta kulaylka hufan. Dabaysha aasaasiga ahi waxa ay wadataa qiimaynta BIL ee 95kV, ta sarena waxa lagu qiimeeyay 30kV, taas oo bixisa difaac adag oo qalliin ah. Khasaaraha culayska ee lagu qiyaasay 85 darajo tuubada maamuluhu waa 1,424 W (la saxay), oo muujinaya waxtarka naxaasta{11}}naqshadda dhaawaca.

image009

 

2.3 Haanta & Xerada

image011

Haanta cylindrical ee tiirka -Transformer-ka ku rakiban – oo laga sameeyay bir sare{1} bir xoog leh oo leh alxanka joogtada ah, saliiddan{2}} xayndaabka ka buuxan ayaa leh ubucda iyo dabaylaha. Qaabkeeda cylindrical waxay yaraynaysaa diiqada farsamada waxayna wanaajisaa xakamaynta cadaadiska. Qaboojinta waxaa lagu gaaraa baalasha jiingado ee dibadda ah ama tuubooyinka qaboojinta kuwaas oo kordhiya aagga dusha sare ee isu-ururinta dabiiciga ah (ONAN). Taangiga waxaa si buuxda loogu xidhay dabool daboolan; cabbirka heerka saliidda iyo cadaadiska cadaadiska ayaa xaqiijiya hawlgal badbaado leh. Xirmooyinka dhejiska ee isku dhafan waxay ku adkeeyaan tiirka, halka lugaha kor u qaadida ay fududeeyaan kor u qaadista. Cimilo waara{8}Daahan u adkaysta waxa ay bixisa ilaalinta daxalka dibada oo dheer.

 

2.4 Burburinta & Joojinta

Aasaasiga ah- joojinta dhinac waxay ka kooban tahay laba dabool oo 15kV ah - Buur geedo ku yaal daboolka sare. Terminalka H1 waa nooc isku dhejis ah oo 4-way ah oo loogu talagalay isku xirka khadka sare ee habboon; Terminalka H2 waxa uu ku xidhan yahay taangiga, isaga oo fududaynaya dhulka dibadda ah.

Dhinaca sare waxa uu leeyahay laba kaydh oo nooca G - oo ku rakiban dhinaca taangiga, ku qalabaysan 3/8{3}}16 bir ah iyo godadka badan ee istadhkiiba si loo helo xidhidhooyin adag oo iska caabin ah. Faahfaahin buuxda oo ku saabsan qaabaynta terminaalka ayaa lagu bixiyay sawirada la ansixiyay.

image013
image015

 

2.5 Is-dhex-galka Qab-qabta Sare

Sida lagu qeexay mashruucan, transformerku waa warshad -ku rakiban hal YH10W-12/40 TL bir-oxide xidhidhiyaha, oo ku rakiban dhinaca hore oo leh garab go'an. Qiimaynta muhiimka ah waxaa ka mid ah:
• danab lagu qiimeeyay: 12kV
• MCOV: 10.2 kV
• Danabka hadhaaga ah (hillaacu 8/20 µs): 36 kV
• Korontada hadhaaga ah (teed): 40 kV
• Korontada hadhaaga ah (bedelka): 33 kV
• 4/10 µs sare - adkaysiga hadda: 100 kA
• 2 ms laba jibaaran -mawjada hada taagan u adkaysata: 400 A

Guryaha silikoonka{0} caag polymer-ku wuxuu bixiyaa iska caabin wasakhaysan oo heersare ah, xasilloonida UV, iyo adkaysiga farsamada ee cirifka dibadda{1}} adeegga ku rakiban. Tiknoolajiyada MOV waxay hubisaa in si degdeg ah loogu xajinayo hillaaca iyo beddelidda qulqulka, ilaalinta dahaarka gudaha ee beddelka. Isdhexgalka warshaduhu waxay meesha ka saaraysaa isku imaatinka garoonka, waxay dammaanad qaadaysaa dejinta saxda ah, waxayna hubisaa ilaalinta joogtada ah ee dhammaan qaybaha.

image017

 

2.6 Qalabka Caawinta Cadaadiska

image019

Jiid -Nooca giraanta YSF ee taxanaha cadaadiska cadaadiska waa qalabka caadiga ah, oo lagu cabiray 0.03 ± 0.01 MPa oo leh awood socod ah 35 SCFM. Inta lagu jiro xaaladaha cilladda, waalka si toos ah ayuu u furmaa si uu u soo saaro gaasaska gudaha oo dib u dajiya marka cadaadisku caadi noqdo. Jiiditaanka gacanta{6}} waxa uu sahlayaa hawo-mareenka la kontoroolo inta lagu jiro dayactirka, buuxinta saliida, ama tijaabada{7}}kor u qaadista badbaadada iyo adeega labadaba.

 

 

03 Hubinta Tayada & Imtixaanka

Transformer kasta si buuxda ayaa loo tijaabiyay marka loo eego shuruudaha CSA C2.2-06, iyadoo dhammaan natiijooyinka lagu diiwaan geliyay warbixin imtixaan oo saxeexan. Hoos waxaa ah qiimayaasha muhiimka ah ee la cabbiray ee ka yimid tijaabada joogtada ah ee cutubka 260411-1 (Taariikhda Imtixaanka: 2026-06-08):

Shayga Tijaabada

Shuruudaha Ogolaanshaha

Qiyaasta Qiimaha

Natiijada

Weecsanaanta Saamiga (tubbada maamulaha)

In ka yar ama la mid ah ± 0.5%

−0.02%

Gudub

Maya- Waayida rarka (100%)

- (tixraac)

0.160 kW

-

Maya- Waayida rarka (105%)

dulqaad +15%

0.190 kW

Gudub

Lumitaanka Culayska (85 darajo)

dulqaad +8%

1.424 kW

Gudub

Caqabada

3.0% ± 7.5%

3.19%

Gudub

Waxtarka

Ka weyn ama la mid ah 98.94%

99.04%

Gudub

Korantada la dabaqay - Primary

34 kV, 60s

Burbur la'aan

Gudub

Voltage Applied - Secondary

10kV, 60s

Burbur la'aan

Gudub

Korantada la kiciyay

2Uur, 180 Hz, 40s

Burbur la'aan

Gudub

Iska caabinta dahaarka (HV+LV ilaa dhulka)

-

44.9 GΩ

-

Tijaabada daadinta haanta

20 kPa, 12h

Wax daadsan

Gudub

Xoogaga Dielectric Oil

-

63.1 kV

-

Qoyaanka Saliida

-

14.7 mg/kg

-

 

Waxtarka la qiyaasay ee 99.04% ayaa dhaaftay CSA C802.1-13 dammaanadda ugu yar ee 98.94%, taasoo xaqiijinaysa waxqabadka tamarta sare ee transformer-ka.

image021
image023

 

 

04 Baakaynta iyo dhoofinta

4.1 Baakad

Transformer kasta waxa uu si toos ah ugu xidhan yahay godad alwaax ah oo raf ah oo loogu talagalay xamuulka badweynta caalamiga ah. Dhammaan meelaha bannaanka ah - baadiyaha, tuubada cadaadiska, iyo xiraha qalliinka{2}} ayaa si gaar ah loogu ilaaliyay suuf xumbo ah oo caado u ah. bannaanka sanduuqa waxa uu soo bandhigayaa lambarka dalabka macmiilka si loo aqoonsado si fudud. Baakadu waxay u hogaansantaa ISPM-15 shuruudaha daawaynta alwaax ee kastamka nadiifka ah.

image025

 

4.2 dhoofinta

image027

Transformers-yadu waxay ku habboon yihiin weelka badda ama maraakiibta sagxadaha leh. Kormeerka hore - waxa uu xaqiijiyaa cabbirada, dhamaystirka isu imaatinka, dhammaystirka dusha sare, iyo calaamadaynta sumadda. Inta lagu jiro rarka, xarunta crate ee cuf-jiidadka ayaa si taxadar leh u toosan, iyo qaadista dharbaaxada waxaa lagu hayaa in ka yar ama la mid ah 30 digrii si loo hubiyo in xitaa qaybinta miisaanka. Xadhkaha sare -xadhkaha xoogga badan iyo xayndaabyadu waxay xaqiijiyaan culayska safarka. Shixnad kasta waxaa ku jira warbixinta imtixaanka rasmiga ah, buug-gacmeedka rakibidda, liiska baakadaha, iyo qaansheegta ganacsiga.

 

 

05 Goobta iyo Kooban

Tan 100 kVA, 13.8/0.347 kV hal - tiirka wejiga -ku rakiban taransfooriyaha waxa uu ka dhigan yahay ka go'naanta SCOTECH ee tayada iyo u hogaansanaanta suuqa Waqooyiga Ameerika. Lagu farsameeyay -xuddun hoose oo silikoon bir ah,dhammaan-dabaylaha naxaasta ah, qaboojinta ONAN, iyo haanta birta khafiifka ah oo si buuxda loo shaabadeeyey, waxa loo dhisay si ay ula kulanto heerarka CSA C2.2{11}}06 iyo CSA C802.1-13 Xireeyaha qalliinka isku dhafan wuxuu bixiyaa ilaalin xoog badan oo koronto ah, taasoo ka dhigaysa transformer-kan doorasho ku habboon qaybinta sare ee gobollada u nugul hillaaca.

Dalabka ku celiska ah ee ka yimi lammaane Canadian ah, mashruucani waxa uu ansaxiyay goobta{0}la xaqiijiyay isku halaynta faylalka isbedbeddelka ee SCOTECH. Kooxdayada farsamadu waxa ay siisa taageero buuxda{2}{2} wareegtada - laga bilaabo xulashada iyo habaynta ilaa xidhiidhka khadka.

image029

 

Hot Tags: 100kva tiir ku rakiban transformer-13.8 / 0.347 kv|kanada 2026, Shiinaha 100kva tiir ku rakiban transformer-13.8/0.347 kv|kanada 2026 saarayaasha, alaab-qeybiyeyaal, warshad