5 Transformer MVA Tareenka-44/6.6 kV|Koonfur Afrika 2025
Awoodda: 5000 kVA
Voltage: 44/6.6 kV
Sifada: kulaylka leh - radiatoor galvanized ah

Sare -Wax ka bedelayaasha Jiidista Waxqabadka - Waxaa loo farsameeyay Xawaaraha & Badbaadada!
01 Guud
1.1 Sharaxaada Mashruuca
5 MVA traction transformer waxaa la geeyey Kanada 2025. Awoodda la qiimeeyey ee transformerku waa 5000 kVA oo leh ONAN qaboojin. Korantada aasaasiga ah waa 44 kV oo leh ± 2 * 2.5% garaacida kala duwan (NLTC), tamarta labaad waa 6.6 kV, waxay sameeyeen koox vector ah Dyn11.
Transformer-kan waxaa loogu talagalay inuu daboolo baahida sahayda korontadu ee saldhigyada jiidista, taasoo bixisa koronto 11 kV iyo 6.6 kV hababka khadka gudbinta. Waxa ay si fiican u qaabaysan - naqshadaysan oo leh shuruudo gaar ah, oo ay ku jiraan ma laha - rarka rarka - beddelka beddelka, hiitarka kulul - dip galvanized dip, iyo valves iyo qalabyada kala duwan. Taangiga wax beddelka waxaa lagu dhisay taarikada birta ah (Ka weyn ama la mid ah 6mm haanta, 16mm ee saxanka hoose) waxayna leedahay qaabayn macquul ah oo ah (bushings), ulo, iyo terminal (oo leh dhexroor cayiman oo iskuxiryo kala duwan ah). Tixgalin gaar ah ayaa la siiyaa dulqaadka iswaafajinta, xoogga farsamada ee dabaylaha, iyo ka hortagga - nashqada wasakhowga (oo leh qaabab midab la qeexay iyo wasakh - dhumucdeedu adkaysi u leedahay). Waxaa loo habeeyey si loo hubiyo hawlgal la isku halayn karo, kulaylka wax ku ool ah, iyo dayactir ku habboon, oo door muhiim ah ka ciyaaraya nidaamka sahayda korantada.
1.2 Tilmaamaha Farsamada
75 kVA tiirka ku rakiban qalabka beddelka nooca iyo xaashida xogta
|
loo geeyey
Koonfur Afrika
|
|
Sannadka
2025
|
|
Nooca
Transformer ku rakiban tiirarka
|
|
Heerka
IEC60076
|
|
Awood lagu qiimeeyay
5000 kVA
|
|
Soo noqnoqda
50 HZ
|
|
Marxaladda
3
|
|
Nooca qaboojinta
ONAN
|
|
Korantada aasaasiga ah
44 kV
|
|
Voltage Secondary
6.6 kV
|
|
Qalabka dabaysha
Copper
|
|
barokaca xagal
Dyn11
|
|
Caqabada
7%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Wax Xamuul ah ma jiro
4.54 kW
|
|
Wax Xamuul ah ma jiro
35 kW
|
1.3 Sawirro
5000 kVA sawir-qaadista jaantuska iyo cabbirka



02 Wax-soo-saarka
2.1 Core
Transformer-ku wuxuu shaqeeyaa saddex{0}waji sedexaad{1}} addin is dulsaaran xudunta dahaarka leh, oo laga dhisay dahaadhka birta silikoon dhuuban (0.23–0.35mm) leh dahaar dahaaran si loo yareeyo khasaaraha hadda jira. Saxsanaan -ku xidhan tilaabo{6}}labo-goysyada dhabta, nakhshadu waxa ay hubisaa in aan - lumin rarka hoose, qaybinta qulqulka dheellitiran, iyo xoog makaanik sare leh si ay ugu adkaysato gariirada tareenada. Sadexda addin ee is haysta{9}} qaabdhismeedka addimada waxa ay wanaajisaa hufnaanta magnetka halka ay dhimayso miisaanka, taas oo ka dhigaysa mid ku haboon nidaamyada awooda jiidashada sare{10}.

2.2 Dabaylaha

Transformer-ka jiidi waxa uu isticmaalaa dabaylaha joogtada ah si uu u helo wax qabad wanaagsan marka la dalbado codsiyada khadka tareenka. Nashqadan adag waxa ay leedahay gariiradaha isku xidhan ee bixiya awood farsamo oo gaar ah si ay ugu adkeysato gariir iyo gaab - xoogag wareeg ah, iyada oo la ilaalinayo sifooyinka korantada ee saxda ah. Tuubooyinka saliidda ee toosan ee dabayshu waxay xaqiijiyaan qaboojin hufan, dhismaheeda kaariyada la wareejiyayna waxay yaraynaysaa khasaaraha hadda socda. Qaabaynta saxanka joogtada ah waxa ay bixisaa danab sare u kaca oo u adkeysan kara awooda iyo qaybinta heerkulka isku midka ah, taas oo ka dhigaysa mid ku habboon in la maareeyo kala duwanaanshaha culeyska soo noqnoqda ee ka jira nidaamyada awooda jiidista. Xalkan is haysta ee weli waaraya wuxuu isku daraa isku halaynta leh koronto iyo kuleyl sare.
2.3 Haanta
Transformer-ku waxa uu leeyahay taangiga rinji oo cawlan{1} Haanta waxaa lagu dhisay hiitariyeyaasha la saari karo ee galvanized galvanized kulul si ay u xoojiso iska caabinta daxalka iyo daadinta kulaylka hufan.
Helitaanka dayactirka, daboolka baadhista ama godad godad ah ayaa si ammaan ah loogu xidhay boolal iyo shaabadeeyayaal si looga hortago daadinta saliidda. Dabool kasta waxaa lagu qalabeeyaa gacan-qaado adag si badbaado leh oo habboon looga saaro inta lagu jiro adeegga.
Nashqadan adag waxay hubisaa adkeysiga, cimilada iska caabinta, iyo dayactirka sahlan ee baahida jawiga tareenka.

2.4 Kulanka ugu dambeeya

1. Golaha dabaysha:Silbadh hore -LV warshadaysan (hoose{1}}voltage) iyo HV (sare{2}}voltage) dabaylaha dul saar xudunta, hubinta toosinta saxda ah ee qaybaha dahaarka (spacers, blocks) oo adkaynaya dabaylaha.
2. Isku xirka Korontada:Samee alxanka ama isku xirka xirmooyinka leexinta leexinta, rakib beddelayaasha tuubada, dahaarka kala goysyada, oo xafid dhammaan isku xirka.
3. Xudunta - Qalajinta gariiradda:Geli qaybta firfircoon ee foornada qallajisa si aad u qallajiso faakuum kulul{0}hawo si ay u saarto qoyaanka, ka dibna xaqiiji iska caabbinta dahaarka inay buuxisay heerarka
4. Golaha Haamaha:Kor u qaad qaybta firfircoon ee engegan ee taangiga, toosi oo sug, ka dibna xidh oo xidh qaybta taangiga hoose.
5. Rakibaadda Agabka:Buuraha bushings, kaydiyaha, cadaadiska cadaadiska, cabbirada heerkulka, gudbinta Buchholz, iyo qalabyada kale, isku xidha dhuumaha iyo wareegyada kormeerka.
6. Buuxinta & Xidhida Saliidda:Samee buuxinta saliida faakuumka ilaa heerka la cayimay, samee tijaabooyinka daadinta
03 Tijaabinta
1. Cabbiraadda gaaska kala diri ee dareeraha dielectric ee qayb kasta oo saliid gaar ah marka laga reebo qaybta beddelaha
2. Cabbirka saamiga korantada iyo hubinta barakaca wejiga
3. Cabbirka caabbinta dabaysha
4. Cabbirka iska caabinta dahaadhka DC ee u dhexeeya dabayl kasta oo dhulka u socota iyo inta u dhaxaysa dabaylaha
5. Go'aaminta dabaylaha dabaylaha dhulka iyo inta u dhaxaysa dabaylaha
6. Tijaabada korantada ee la dabaqay (AV)
7. Cabbirka maya - lumitaanka iyo hadda
8. Tijaabada adkaysiga korantada ee keentay
9. Cabbirka Gaaban -kahortagga wareegga wareegga iyo luminta culayska
10. Cabbirka gaaska kala diri ee dareeraha dielectric ee qayb kasta oo saliid gaar ah marka laga reebo qaybta beddelaha
11. Tijaabada Diidmada Cadaadiska Dareeraha -Tightness Testing


04 Baakaynta iyo dhoofinta
4.1 Xirxirida
Transformer-ka waxa si sugan loogu rakibaa sanduuq alwaax ah oo la xoojiyay iyadoo la isticmaalayo birta ama birta, qaybo nugul sida buunshooyin lagu duudduubay shoog{0}}wax nuugaya. Haanta waa saliid -waxaa ka buuxsamay ama ka buuxsamay hawo engegan/nitrojiin, iyo sanduuqa waxaa lagu dahaadhay qoyaan{3}}filimka aan biyaha lahayn waxaana lagu xidhay cajalad aan biyuhu lahayn. Qaab dhismeedka alwaax ee adag waxa uu leeyahay godadka forklift/lugaha kor u qaada, xoojinta birta, iyo daboolka roobka ee jilcan.
Calaamadaha dibadda waxaa ka mid ah miisaanka, cabbirka, calaamadaha wax ka qabashada, iyo calaamadaha halista, halka dukumeentiyada gudaha (liiska xirmada, buug-gacmeedyada, warbixinnada tijaabada) lagu keydiyo boorso aan biyuhu karin.

4.2 dhoofinta

Transformer-ka ayaa si ammaan ah loogu raray gaari fidsan waxaana loo daabulaya dekedda shixnadda. Shuruudaha CIF, alaab-qeybiyaha ayaa gacanta ku haya xamuulka badda, oo ay ku jirto ballansashada markab ku habboon oo leh xasilin habboon (tusaale, maroojin qufulka weelasha ama garaaca jabsiga). Sanduuqa alwaaxdu waa la dhigaa si looga fogaado soo-gaadhista qoyaanka, iyadoo ay ku lifaaqan yihiin tilmaamayaasha shoogga/gariirka. Caymiska wuxuu daboolaa khataraha badda (Dhammaan Khatarta ICC Farqada A). Marka la yimaaddo dekedda Durban, shixnadda waxaa lagu dejiyaa iyadoo la isticmaalayo wiishashka dekedda, waxaa lagu nadiifiyaa kastamka ( alaab-qeybiyaha ayaa qabanqaabiya dukumeenti dhoofinta, iibsaduhu wuxuu gacanta ku hayaa oggolaanshaha soo dejinta), waxaana la geynayaa goobta la cayimay. Dabaqadaha gaarka ah ayaa laga yaabaa in loo baahdo cutubyo waaweyn.
05 Goobta iyo Kooban
Iyada oo ah tiir-dhexaadka jiidashada tareenada iyo nidaamyada korantada, transformers-yadayada jiidista waxay keenaan isku hallayn, hufnaan, iyo is-afgarad la'aan ee jidadka tareenada caalamiga ah, metros, iyo tareennada isku-dhafan. Muujinaya nakhshad qaabaysan, dahaar qaali ah, iyo la socosho fiican, waxay ku fiican yihiin bay'ad adag oo leh khasaare yar, buuq, iyo cimri dherer. Iyadoo lagu taageerayo xalal la habeeyey iyo maaraynta meertada nolosha, waxaan hubineynaa taageerada aan kala go 'lahayn ee naqshadeynta ilaa gaarsiinta caalamiga ah. Nala soo xiriir si aad u hesho faahfaahin farsamo ama daraasado kiis - oo awood u siinaya mustaqbalka dhaqdhaqaaqaaga si kalsooni leh.

Hot Tags: Transformer tareenka, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
6 Beddeleyaasha Tareennada ee MVA-22/1.22 kV|Koonfur...
3000 kVA Transformer-25/0.6 kV|Kanada 2025
2500 kVA Pad Mount Transformer-12.47 / 0.48 kV|USA 2025
630 kVA Vpi Nooca Beddelka-11 / 0.55 kV|Koonfur Afri...
5 Beddelka Jidka Tareenka ee MVA-132/1.22 kV|Koonfur...
2000 kVA suuf Ku rakiban Beddelka-24/0.48 kV|USA 2024
U dir sooji