5 MVA Traction Transformer-22 / 6.6 kV|Koonfur Afrika 2025

5 MVA Traction Transformer-22 / 6.6 kV|Koonfur Afrika 2025

Dalka: Koonfur Afrika 2025
Awoodda: 5000 kVA
Voltage: 22/6.6 kV
Sifada: kulaylka leh - radiatoor galvanized ah
U dir sooji

 

 

Traction Power Transformer

Kordhi waxtarkaaga tareenka Ka bilow Transformer-ka jiidista.

 

 

01 Guud

1.1 Sharaxaada Mashruuca

5 MVA traction transformer waxaa la geeyey Kanada 2025. Awoodda la qiimeeyey ee transformerku waa 5000 kVA oo leh ONAN qaboojin. Korantada aasaasiga ah waa 22 kV oo leh ± 2 * 2.5% garaacista (NLTC), korantada labaad waa 6.6 kV, waxay sameeyeen koox vector ah Dyn11.

Iyada oo laga jawaabayo xaaladaha hillaaca (12 ilbiriqsi dhul kiiloomitir laba jibaaran sannadkii) iyo buufinta milixda daran iyo wasakhowga soot warshadaha ee Koonfur Afrika, naqshadeeda ayaa si buuxda u tixgelinaysa ilaalinta dahaarka iyo iska caabinta daxalka. Haanta shidaalka ayaa ka samaysan bir dhumucdeedu ka weyn tahay ama le'eg tahay 6mm, dhumucda saxanka hoosena waxa uu gaaraa 16mm. Dhumucda dahaarka ee meelaha aadka u wasakhaysan waa 125 microns. Intaa waxaa dheer, haanta shidaalka iyo hiitarka waxay qaataan nashqada alxanka oo ku habboon si loo hubiyo awoodda qaabdhismeedka iyo waxqabadka xirmidda.

Marka la eego qaabaynta shaqada xudunta u ah, transformerku waxa uu ku qalabaysan yahay NLTC maya-load tap- beddele, taageeraya kala duwanaanta nidaaminta korantada ee ±2×2.5% iyo muujinta shaqaynta qufulka leh si loo hubiyo nidaaminta tamarta saxda ah iyo badbaadada. Dabaysha hoose ee - waxay u adkeysan kartaa wadarta qallooca korantada ee ilaa 27%, iyadoo la qabsanaysa deegaan koronto oo adag. Dabayshu waxay leedahay awood farsamo oo ku filan oo ay iskaga caabiso qulqulka ciladaysan, qaybta nooluna waxay leedahay nadiifin dhulka ah 3500mm, iyada oo u hogaansanta{9}} heerarka hawlgalka badbaadada korantada sare. Dhanka kale, qalabku waxa uu ku qalabaysan yahay qalab ilaalin badan, oo ay ku jiraan hal -soo gudbinta gaasta sabaynaysa (oo leh alaarmiga iyo xidhiidhka safarka), gudbinta kulaylka xad dhaafka ah (oo leh magdhow heerkulka deegaanka, heerkulka safarka la dejiyay 115 digrii), garaac - Nooca heerkulbeegyada dusha saliida (xidhiidh la hagaajin karo oo lagu dejiyay 90 digrii), iyo la socoshada cadaadiska wakhtiga hawlgalka kaas oo si degdeg ah uga jawaabi kara wakhtiga shaqaynta

 

 

 

1.2 Tilmaamaha Farsamada

5000kVA nooca qeexida transformer jiidida iyo xaashida xogta

loo geeyey
Koonfur Afrika
Sannadka
2025
Nooca
transformer jiid
Heerka
IEC60076
Awood lagu qiimeeyay
5000 kVA
Soo noqnoqoshada
50HZ
Marxaladda
3
Nooca qaboojinta
ONAN
Korantada aasaasiga ah
22 kV
Voltage Secondary
6.6 kV
Qalabka dabaysha
Copper
barokaca xagal
Dyn11
Caqabada
7%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
4.4 kW
Load Lumista
35 kW

 

1.3 Sawirro

5000 kVA sawir-qaadista jaantuska iyo cabbirka

Traction Power Transformer diagram Traction Power Transformer nameplate

 

 

02 Wax-soo-saarka

2.1 Core

Xudunta wax-bedelku waa wareegga magnetic dhexe ee beddelka jiidista. Laga soo dhisay - dalaayadaha birta ee silikoon ee permeability ee sareeya, waxay si hufan u gudbisaa kanaalka beddelka qulqulka magnetic oo leh tamar aad u yar. Tani waxay muhiim u tahay beddelka tamarta la isku halayn karo iyo hawlgalka deggan ee xaaladaha baahida gaadiidka tareenka.

traction transformer core

 

2.2 Dabaylaha

continuous disc winding

Dabaysha saxanka ee joogtada ah waa nooca gariiradda muhiimka ah ee transformers jiidida. Waxay ku samaysaa dabaylaha leydi-geeska ah ee taxane ah oo saxannada radial ah oo aan lahayn kala-goysyada alxan ee u dhexeeya leexashada. Qaab dhismeedkan farsamaysan ee adag waxa uu bixiyaa -xoog wareeg ah oo aan caadi ahayn iyo kulayl wax ku ool ah, kuwaas oo muhiim u ah hawlgal la isku halayn karo oo hoos yimaada isbedbedelka rarka.

 

2.3 Haanta

Haangu waxa ay u adeegtaa sidii xayndaabka ilaalinta iyo nidaamka qaboojinta dhex-dhexaadka ah ee beddelka jiidista. Waxay si farsamaysan u adag tahay inay u adkaysato gariirrada iyo saamaynta, halka nashqaddeedu ay hagaajinayso kala daadsanaanta kulaylka si loo hubiyo in xudunta iyo dabayshu ay ku shaqeeyaan heerkul ammaan ah, dammaanad qaadaya isku halaynta marka la eego shuruudaha adeegga.

image011

 

2.4 Kulanka ugu dambeeya

railway transformer assembled

Isu imaatinka kama dambaysta ahi waa habka muhiimka ah ee isku xidhka xudunta, dabaylaha, iyo taangiga isu beddelka jiidista oo dhammaystiran oo la isku halayn karo. Waxay hubisaa toosinta saxda ah ee makaanikada, daacadnimada korantada, iyo saliidda- xidhid adag, taasoo keenta unug adag oo awood u leh inay keenaan hawl qabad cayiman oo hoos yimaada shuruudaha shaqada tareenka.

 

 

03 Tijaabinta

Transformer-kani waxa uu maray taxane dhammaystiran oo joogto ah, nooca iyo tijaabooyin gaar ah si loo xaqiijiyo daacadnimadeeda korantada, hufnaanta hawleed, iyo isku halaynta muddada dheer{{0}. Nidaamka tijaabada adag, daboolaya xoogga dielectric, khasaaraha, saamiga, dahaarka, iyo gaaska - gudaha - falanqaynta saliidda, waxay xaqiijinaysaa u hoggaansanaanta buuxda ee unugga qeexida waxqabadka iyo u diyaargarowga dalabka adeegga tareenka.

railway transformer test
Traction Power Transformer test

 

 

04 Baakaynta iyo dhoofinta

4.1 Xirxirida

Baakadaha transformer-ka jiidashada waxaa loogu talagalay ilaalinta ugu badan inta lagu jiro gaadiidka iyo kaydinta. Ka faa'iidaysiga qaab-dhismeed adag oo cimilo-celin leh oo leh xayndaab la habeeyey, waxay hubisaa daacadnimada unugga ka-hortagga jahawareerka farsamada, gariirka, iyo arrimaha deegaanka, dammaanad qaadka imaatinka badbaadada leh ee goobta rakibidda.

 safe arrival

 

4.2 dhoofinta

international sea transit

Shixnadda taransfoorka jiidista waxa lagu fuliyaa shuruudaha CIF (Qiimaha, Caymiska, iyo Xamuulka), iyadoo siinaya deked dhammaystiran{0}} ilaa{1}} xalalka saadka ee dekedda. Mas'uuliyadeena waxay koobeysaa dhammaan habka lagu gaarsiinayo unugga si badbaado leh Dekedda Durban, Koonfur Afrika. Tan waxa ku jira maaraynta kastamka dhoofinta, sugidda adeegga xamuulka badda ee xudunta u ah, iyo diyaarinta caymiska xamuulka oo buuxa, iyadoo dhammaan kharashyada la xiriira la daboolay. Habkani waxa uu siinayaa macmiilka hubanti la taaban karo iyo yaraynta khatarta, iyada oo la hubinayo in qalabka muhiimka ah si xirfad leh loo maareeyo inta lagu jiro safarka caalamiga ah ee badda ilaa laga sii daayo dekedda uu ku socdo.

 

 

05 Goobta iyo Kooban

Xudunta u ah adduunka awoodda, xasilloonida iyo hufnaanta ayaa ah daba-gal weligeed ah. Transformers-yadayadu maaha oo kaliya aaladaha saxda ah ee u beddela tamarta korantada awood xoog leh, laakiin sidoo kale dhagaxa rukunka ah ee xanbaarsan badbaadada, ilaalinta waqtiga iyo kalsoonida. Laga soo bilaabo fikradda naqshadaynta bilawga ilaa tijaabada adag ee kama dambaysta ah, raadintayada hagar la'aanta ah ee ugu wanagsan ee tafaasiil kasta waa in la hubiyo in bilow kasta{2} iyo safar kasta, aanu ku bixin karno taageero aamusan oo xoog badan.

Doorashada alaabtayada waxa ay la macno tahay in aad dooratay lamaane waqti dheer la aamini karo- Waxa aanu balan qaadaynaa in aanu kula socono mustaqbalka gaadiidka casriga ah adiga oo adeegsanayna tignoolajiyad heersare ah, tayo la isku halayn karo iyo dhamaan adeegyada wareega, samaynta xidhiidh kasta oo awood buuxda leh.

traction transformers

 