5 MVA Traction Transformers-132 / 1.22 KV|Koonfur Afrika 2025
Awoodda: 5000 kVA
Voltage: 132/ 2*1.22+0.635 kV
Feature: danab dabaylaha sare: 150kVA, 0.635kV
Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha 5 mva ugu kalsoonida badan -132/1.22 kv|Koonfur Afrika 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

Beddelka Jiidista - Awoodda Dhaqdhaqaaqa
01 Guud
1.1 Sharaxaada Mashruuca
5000 kVA traction transformer ayaa la geeyey Koonfur Afrika sanadka 2025. Awooda lagu qiimeeyay taransfoomiyaha waa 5000 kVA oo leh ONAN qaboojin. Korontada sare waa 132 kV oo leh ±2*2.5% garaacista (NLTC), danab yar waa 2*1.22+0.635 kV, waxay samaysteen koox ka kooban Y/d±15 digrii d11.
Dawaarle{0}oo loo sameeyay xaaladaha qalafsan ee shaqada ee South Africa, 5MVA traction transformer waxa uu u adeegaa sida dammaanadda udub dhexaadka u ah nidaamyada korantada jiidida tareenka, isku xidhka qaabaynta cabbirka saxda ah iyo la qabsiga deegaanka ee heer sare leh oo leh -naqshad la isku hallayn karo iyo xalal farsamo oo la habeeyey si si fiican ugu waafaqo kakan{3} shuruudaha hawlgalka goobta.
Marka la eego cabbirrada xudunta ah, transformerku waxa uu leeyahay awood la qiimeeyay oo ah 5000kVA, danab hoose oo ah 132kV, iyo dhinaca labaad ee qaadanaya 2×1.22kV dual delta{4} dabaylaha (oo ku qalabaysan baadiyaha madax-bannaan si ay u siiyaan koronto beddelka kaaliyaha). Iyadoo ku shaqaynaysa 50Hz, waxay isticmaashaa{11}maxaasta dabeecadda sare ee dabaylaha si loo hubiyo gudbinta awood hufan oo degan. Kooxda isku xidhka waxa loo nashqadeeyay sida Ydd±15 digrii , oo leh 15 shahaado wareeg ah oo u dhexeeya labada dabaylaha hoose{15}}, kaas oo si wax ku ool ah u wanaajinaya tayada awooda nidaamka jiidashada iyadoo la yareynayo saamaynta faragelinta iswaafajinta iyada oo loo marayo naqshad gaar ah.
Bartilmaameedka adag{0}} xaaladaha goobta South Africa- oo ay ku jiraan wasakhda culus, isbedbeddelka korantada (±5% xaaladaha caadiga ah, -15% xaaladaha gaarka ah), kala duwanaansho heerkul balaadhan ({12}}10 darajo ilaa +55 darajo), joog sare (0{13}}1800m oo dhan), iyo huurka qoyaanka 9% qaab dhismeedka dabaysha, haanta shidaalka oo ka weyn ama le'eg 6mm saxan bir qaro weyn leh (16mm saxan salka qaro weyn), radiatooriyeyaasha-ka-hortagga daxalka ee kulul, oo ay weheliso ilaaliye leh kaadiheysta iyo neefta, gaaritaanka iska caabin qoyaan oo xooggan, ilaalinta daxalka, iyo ilaalinta dahaarka. Waxay u adkeysan kartaa hillaaca HV/LV1/LV{16}}/60kV oo waxay leedahay awood farsamo oo ku filan oo ay iskaga caabiso saamaynta mawjadaha cilada leh, iyada oo hubinaysa in hawlgal xasiloon marka lagu jiro xaalado aad u daran.
Marka la eego waxqabadka, transformer-ku wuxuu qaataa qaboojinta ONAN (Oil Natural Air Natural). Kor u kaca heerkulka dabayshu kama dhaafo 65 digrii oo si buuxda u socda{2}} hawlgalka culayska ka dib marka la gaadho dheellitirka kulaylka iyo heerkulka deggan. Waxa ay si fudud ula qabsan kartaa caqabadaha wakhtiga gaaban -: kor u kaca heerkulka waxa lagu xakameynayaa 70 darajo -100 darajo marka la eego xaaladaha shaqada ee 3x load 1 daqiiqo, 3.5x load 10 sekan, iyo 2x load 30 daqiiqo Qalabka muhiimka ah waxaa ka mid ah NLTC off{18}} beddelka tuubada wareega (± 2×2.5% hagaajinta shaqada qufulka), hal - gaaska sabbaynaya (oo leh alaarmiga iyo safarka), tusaha heerkulka dabaysha oo leh magdhow heerkulka jawiga (oo lagu safri doono 115 digrii), iyo sanduuq terminal leh oo leh heerka ilaalinta IP55. Intaa waxaa dheer, dhererka baadiyaha ayaa la hagaajiyay si uu u dhigmo shuruudaha rakibaadda baska sare ee 2.7m, oo leh daaqad indho-indhayn/ godka sare ee dayactirka fudud, iyo tuubooyinka shaandhada saliidda ee lagu kaydiyay dhinaca haanta shidaalka, si guud u hagaajinaysa ku habboonaanta hawlgelinta iyo dayactirka.
Laga soo bilaabo qaab dhismeedka dabaysha (Seega joogtada ah-nooca danab sare, wareeg{1}}nooca danab hoose) ilaa xulashada alaabta iyo culayska - awooda xajinta, transformer-kan ayaa si buuxda loogu habeeyey sifooyin gaar ah nidaamyada sahayda korontada Kaliya ma buuxinayso shuruudaha waafaqid ee laba iyo tobanka - hagaajinta garaaca wadnaha laakiin sidoo kale waxay siisaa dammaanad madax banaan oo loogu talagalay sahayda tamarta kaaliyaha ah iyada oo loo marayo dabaylaha sare, taas oo ka dhigaysa xalka korantada jiidashada ugu fiican oo leh- faragalin, iska caabin adag deegaanka, iyo badbaadada sare ee mashruuca Koonfur Afrika.
1.2 Tilmaamaha Farsamada
5000 kVA nooca tilmaanta beddelka jiidista iyo xaashida xogta
|
loo geeyey
Koonfur Afrika
|
|
Sannadka
2025
|
|
Nooca
suuf ku rakiban transformer
|
|
Heerka
IEC60076
|
|
Awood lagu qiimeeyay
5000 kVA
|
|
Soo noqnoqda
50HZ
|
|
Marxaladda
3
|
|
Nooca qaboojinta
ONAN
|
|
Korantada aasaasiga ah
132 kV
|
|
Voltage Secondary
2*1.22+0.635 kV
|
|
Qalabka dabaysha
Copper
|
|
Kooxda Vector
Y/d±15 darajo d11
|
|
Caqabada
8.2(±10%)%
|
|
Taabo Beddelka
NLTC
|
|
Riixista Range
±2*2.5%
|
|
Wax Xamuul ah ma jiro
7.7 kW
|
|
Load Lumista
26.5 kW
|
1.3 Sawirro
5000 kVA sawir-qaadista jaantuska iyo cabbirka
![]() |
![]() |
02 Wax-soo-saarka
2.1 Core

Xudunta taransfoorayaasha jiiditaanku waxa ay ka samaysan yihiin dahaaran, sare -permeability, hoose{1}}alaabta khasaaraha -qabow{3}} hadhuudh duuban - bir silikoon ku jihaysan. Naqshadeynta si ay u noqoto mid adag oo is haysta, waxay u adkeysaneysaa culeysyada soo noqnoqda ee saameeya iyo gariirada makaanikada ee ku jira hawlgalka tareenka. Lamination-yada waxaa inta badan la isugu keenaa kalagoysyo si buuxda u laablaaban oo kala go'an si loo yareeyo rabitaan la'aanta magnetic iyo wax - khasaare ah Tallaabooyin wax-ku-qabsi ah oo wax-ku-ool ah ayaa udub-dhexaad u ah naqshadeeda, hubinta dariiqa magnet-ka ah ee deggan oo hufan ee isbeddelka korantada ee la isku halleyn karo iyo wareejinta korantada ee hoos yimaada shuruudaha baahida.
2.2 Dabaylaha
Dabaylaha joogtada ah ee transformers jiid-jiidashada ayaa inta badan laga sameeyaa silig siman oo naxaas ah ama kirishbooyada joogtada ah (CTC). Waxay ku dhaawacantay qaab saxan joogto ah oo aan lahayn - isgoysyada saxanka, oo ay ka muuqato luminta AC yar iyo diridda kulaylka la midka ah; iyada oo la wanaajinayo naqshadaynta dahaarka si loo xakameeyo diiqada tamarta, waxay sidoo kale buuxin kartaa shuruudaha xoogga farsamada ee xaaladaha shaqada sida 3.5 jeer xad dhaaf ah. Qaab dhismeedkan waxa caadi ahaan loo qaataa dabaylaha sare ee -, kaas oo la qabsan kara 12-pulse rectifiers, kaas oo siinaya dariiq magnetoelectric deggan si loogu beddelo tamarta wax ku oolka ah ee nidaamyada jiidista iyadoo la raacayo shuruudaha dahaarka buuxda si loo hubiyo badbaadada hawlgalka.

2.3 Haanta
Taangigu waxa uu ka samaysan yahay bir dhumucdiisu ka weyn tahay ama le’eg tahay 6mm ( dhumucdiisuna waxay tahay 16mm), daboolkeeda sarena waxa ku xidha boolal. Dusha sare waxa lagu rinjiyeeyay cawl leh dhumucdiisuna tahay rinji aan ka yarayn 125 microns. Gudaha taangiga waxaa ka buuxsamay saliid isbedbedesha, taas oo bixisa dahaarka iyo kulaylka kala-baxa xudunta birta iyo dabaylaha. Waxay la shaqeysaa kulaylka la go'i karo{6}}radiyeeriyeyaasha galvanized leh rinji si loo gaaro qaboojinta, oo waxay ku xiran tahay ilaalinta saliidda kaadiheysta cad isla mar ahaantaana si loo hubiyo in jirka beddelka uu had iyo jeer la geliyo saliid. Haanta ugu weyn waxa lagu qalabeeyay hal tuubo oo tubo leh (oo leh dun gudaha ah oo 50mm ah) oo ku taal labada dhinac ee kaydiyaha saliidda iyo dhinaca ka soo horjeeda, taas oo loo isticmaalo isku xirka shaandhada saliidda oo ku habboon hawlgalka dhulka -Hal tuubo ayaa lagu habeeyaa meel sare, midda kalena meel hoose (-meelka hoose ee mid ka mid ah waxa lagu dari karaa waalka dheecaanka saliidda haddii loo baahdo). Taangiga waxaa sidoo kale lagu rakibay qalab ilaalin ah sida tuubada cadaadiska cadaadiska, waxayna u baahan tahay in ay la jaanqaaddo bushings kuwaas oo qaybahooda nool aysan ka badnayn 2.7m dhulka ka sarreeya, si ay u buuxiyaan shuruudaha hawlgalka ee meelaha wasakhaysan ee culus iyo danabka daran ee Koonfur Afrika, iyo sidoo kale hoos yimaada xaaladda 3.5x.


03 Qalabka
3.1 Hilibka kululeeyaha galvanized

Hidiyeteriyahan la go'i karo wuxuu leeyahay saldhig kuleyl leh oo leh daahan rinji dheeri ah, waa ku haboon yahay habka qaboojinta Transformer-ka ee ONAN si uu u caawiyo kala dirida kulaylka, waxaana loogu talagalay in uu la qabsado xaaladaha adag ee Koonfur Afrika (wasaq culus, kala duwanaansho heerkul ah -10~+55 heerkul ah -10~+55 heerkul ah -10~+55 heerka heerkulka dheer) iyo 3. iska caabin iyo xasilooni dhismo.
3.2 Tusiyaha heerkulka dabaysha
Tilmaamaha heerkulka dabaylaha (oo loo arko inuu yahay raay kulaylka culayska badan) waxa loo nashqadeeyay inuu ka ilaaliyo transformer-ka culayska xad-dhaafka ah, oo wata culays{0}}heerkulka (qiyaastii heerkulka goobta ugu kulul) xidhiidhinta iyo shaqada magdhowga heerkulka jawiga; waxay ku qalabaysan tahay xidhiidh safar oo loo dejiyay 115 digrii (ku salaysan 45 darajo heerkulka deegaanka + 70 darajo sare u kaca heerkulka ugu sareeya) waxayna leedahay qiyaasaha korantada ee 110V DC iyo 6A, kaas oo la qabsan kara isbedbedelka xaaladaha adag ee shaqada sida 3.5x load si loo hubiyo hawlgal badbaado leh.

3.3 Sanduuqa Terminalka

Sanduuqa terminaalka taransfooriyahan waxa uu leeyahay qiimaynta ilaalinta IP55, isaga oo si wax ku ool ah uga hortagaya boodhka soo galaya iyo hoose - cadaadiska biyaha firdhinaya, waxaana loo habeeyey si uu ula qabsado xaaladaha adag ee goobta{2}} ee Koonfur Afrika (oo ay ku jiraan wasakhda culus, heerkul kala duwan oo -10~+55 heerkul ah, iyo 10%-90% qoyaan qaraabo ah). Waxay u adeegtaa si ay u ilaaliso isku xirka korantada gudaha, hubinta fiilooyin la isku halayn karo iyo gudbinta ishaarada ee transformer-ka xitaa marka lagu jiro xaaladaha adag ee hawlgalka sida culeyska 3.5x, sidaas darteed ilaalinta hawlgalka xasilloon ee qalabka.
04 Tijaabinta
Tan 5000kVA 132/2×1.22+0.635Transformers traction kV waxa ay dhamaystirtay tijaabooyin taxane ah oo joogto ah si waafaqsan heerarka korantada ee la xidhiidha, oo ay ku jiraan 24{6}saac tijaabo cadaadis cadaadis ah oo 30kpa ah oo aan lahayn wax dareere ah, tijaabooyinka saliida dahaarka (gaasta kala diri iyo ogaanshaha qoyaanka), xakamaynta cabirka heerka korantada iyo luminta heerka dabaysha xaqiijinta barakicida, iska caabinta dabaysha, gaabnaanta-cidhiidhiga wareegga, maya-imtijaabada culayska iyo rarka luminta, saamiga iyo hubinta polarity ee transformers-yada hadda ku dhex jira, tijaabada danabka la dabaqay, tijaabada adkaysiga korantada ee leh cabirka dareeraha qayb ka mid ah (PD), iyo tijaabada dahaarka kaaliyaha Dhammaan natiijooyinka imtixaanku waxay u hoggaansamaan shuruudaha farsamada, transformer-ka ayaa ugu dambeyntii loo arkaa inuu yahay mid u qalma, oo awood u leh inuu daboolo baahidiisa xaalad shaqo.


05 Baakaynta iyo dhoofinta


06 Goobta iyo Kooban
Tan 5000kVA 132/2×1.22+0.635kV isbedbedelka jiidista waxa loo qaabeeyey oo loo soo saaray si adag oo waafaqsan heerarka korontada ee khuseeya. Waxaa la waafajiyay xaaladaha adag ee - xaaladaha goobta South Africa, oo ay ku jiraan wasakhda culus, hillaaca daran, iyo kala duwanaanta heerkulka -10~+55 darajo, faanista sifooyinka asaasiga ah sida 3.5x culeyska adkaysi u leh, dahaarka buuxa, iyo xoogga farsamada sare. Naqshadeynta qaybaha muhiimka ah iyo qaab-dhismeedka ayaa si buuxda u buuxinaya shuruudaha hawlgalka. Lagu xaqiijiyay tijaabooyin taxane ah oo joogto ah, dhammaan tilmaamayaasha oo ay ku jiraan waxqabadka shaabadeynta, heerka dahaarka, saxnaanta saamiga korantada, iyo xakamaynta luminta waxay u hoggaansamaan tilmaamo farsamo, iyo transformer-ka ayaa ugu dambeyntii loo arkaa mid u qalma. Awood u leh in uu si degan ula qabsado 12-pulse rectifier units, transformer-kani waxa uu bixiyaa taageero tamar wax ku ool ah oo badbaado leh nidaamka jiidista, isaga oo si buuxda u qancinaya kalsoonida iyo baahida adkeysiga ee hawlgalka goobta.

Hot Tags: Transformers jiidashada, saaraha, alaab-qeybiyaha, qiimaha, qiimaha
You Might Also Like
6 Beddeleyaasha Tareennada ee MVA-22/1.22 kV|Koonfur...
5 Transformer MVA Tareenka-44/6.6 kV|Koonfur Afrika ...
5 Beddelka Jidka Tareenka ee MVA-132/1.22 kV|Koonfur...
5 MVA Traction Transformer-22 / 6.6 kV|Koonfur Afrik...
5 MVA Model Tareenka Beddelka-66/1.22 KV|Koonfur Afr...
5.05 MVA Railway Transformers-132/2*1.22+2.36 KV|Koo...
U dir sooji