150 kVA Bedelka Guryaha Korontada-24.94/0.208 kV|USA 2024

150 kVA Bedelka Guryaha Korontada-24.94/0.208 kV|USA 2024

Dalka: Shiinaha 2024
Awoodda: 150kVA
Voltage: 24.94/0.208kV
Feature: oo leh fiyuuska bayonet
U dir sooji

 

 

20250908164308426177

Tayada qaaliga ah,-waxqabad waara,iyo nakhshad garaad leh -Saddex{1}Pad Pad{2}}Transformer, ilaalinaya mustaqbalka nidaamyada korantada!

 

01 Guud

1.1 Asalkii Mashruuca

SCOTECH waxay dhawaan dhoofisay sare ---line 150KVA saddex waji qaybinta suufka ku rakiban transformer-ka Jamaica. Awoodda lagu qiimeeyay taransfooriyaha waa 150 kVA oo leh qaboojin ONAN. Korontada aasaasiga ah ee transformer-ku waa 24.94GrdY/14.4kV, halka danabka labaadna uu yahay 0.208GrdY/0.12kV oo leh laba danab oo dhanka LV ah. waxay samaysteen koox fallaago ah YNyn0. Isticmaalka isku xidhka YNyn0 iyo sadex{14} wajiga shanaad{15}}qaabka tiirka, tayada danabka sareeyo, barta dhex dhexaadnimadu ma liidato, sanduuqa ma kululeeyo, buuq yar, waxqabadka ilaalinta hillaaca wanaagsan. Dhanka sare- dhinaca korantada ee suufka -ku rakiban taransfooraha wuxuu ku xidhaa dhexdhexaadiyaha{19}}shabakadda qaybinta korantada. Ka dib marka la dhex maro kuwa sare -kumbuyuutarrada culeyska korantada iyo fiyuusyada, hadda wuxuu ku qulqulaa dabeylaha taransfoorayaasha, halkaasoo beddelka danabku uu ka dhaco. Dhinaca korantada hoose{23}}ka dibna waxay siisaa awooda rarka iyadoo loo marayo isku xirka terminaalka,iyaga oo taageeraya saddex{24}}waji, afar{25}}nidaamka korontada

 

1.2 Tilmaamaha Farsamada

150 KVA suuf ah oo ku rakiban tafatirka tafatirka iyo xaashida xogta

loo geeyey
Kanada
Sannadka
2024
Nooca
suuf ku rakiban transformer
Heerka
IEEE C57.12.00
Awood lagu qiimeeyay
150KVA
Soo noqnoqda
60HZ
Marxaladda
3
Nooca qaboojinta
ONAN
Korantada aasaasiga ah
24.94GRDY/14.4 KV
Voltage Secondary
0.208GrdY/0.12 KV
Qalabka dabaysha
Aluminium
barokaca xagal
YNyn0
Polarity
Wax lagu daro
Caqabada
3.5±7.5%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
0.45KW
Load Lumista
1.7KW
Agabka
Habaynta caadiga ah

 

1.3 Sawirro

150 KVA suuf ku rakiban jaantuska beddelka sawirka iyo cabbirka.

20250908164059424177 20250908164033423177

 

 

02 Wax-soo-saarka

2.1 Core

Ficilka muhiimka ah - qayb ka mid ah wareegga magnetic

Si loo dhimo hysteresis iyo luminta hadda jira ee xudunta birta, xudunta birta waxaa lagu dhejiyaa 0.35 ~ 0.5mm qaro weyn oo kulul ama silikoon go'yaal qabow oo duuban, iyo qaybaha waxaa lagu dahaadhay 0.01 ~ 0.013mm filim rinji qaro weyn si looga fogaado wareegga gaaban ee u dhexeeya qaybaha.

Isticmaalka isdul-saaridda xudunta udub-dhexaadka u ah (transformers-yada waaweyn waxay isticmaalaan xaashida birta diagonal) waxay yareyn kartaa farqiga hawada waxayna yareyn kartaa xamaasadda hadda jirta.

image007

 

2.2 Dabaylaha

image009

Ficilka dabaylaha - qayb wareeg ah

Waxaa lagu duudduubay warqad, dun ama silig fidsan ama silig asal ah, kaas oo keeni kara karti iyo xaqiijinta beddelka tamarta korantada ee hadda jirta.

Dabayshu waxay qabataa qaab-dhismeedka xoogga leh. Waxa loogu yeero dabaylaha diiradda saaraya waa in qayb kasta oo istallaabta ah ee tiirarka xudunta u ah, dabaysha ayaa la dejiyay bannaanka tiirka xudunta leh isla xariiqa cylindrical. Waa in uu jiraa farqi dahaar ah oo gaar ah iyo kanaalka kala daadinta kulaylka (marabka saliidda) ee u dhexeeya dabaylaha tamarta sare iyo kuwa hoose, iyo sidoo kale inta u dhaxaysa dabaylaha danab yar iyo tiirka xudunta ah, oo ay kala soocaan tuubo kartoon ah oo dahaaran. Baaxadda masaafada dahaarka waxay kuxirantahay heerka korantada ee dabaysha iyo farqiga looga baahan yahay kanaalka kuleylka kuleylka. Marka dabaylaha hoose - la dhigo gudaha meel u dhow tiirarka xudunta u ah, masaafada dahaarka ee loo baahan yahay ee u dhexeeya isaga iyo tiirka xudunta ayaa ah mid yar, markaa cabbirka dabaysha waa la dhimi karaa, cabbirka guud ee beddelka sidoo kale waa la dhimay.

 

2.3 Haanta

Shaqada haanta saliidda: xudunta birta iyo dabaysha ayaa ka kooban jidhka transformer-ka, kaas oo lagu dhejiyo haanta saliidda ee ku qalabaysan transformer-ka, saliidda transformer-kuna waa dhexdhexaad dhexdhexaad ah iyo dhexdhexaad ah qaboojinta.

Transformer-ka noocaan ah ee ay soo saarto shirkadeena waxay qabataa taangiyada nooca sanduuqa (tan laalaada nooca core). Daboolka sanduuqa sare ee isbeddelka waa la furi karaa, miisaankiisa guud ka dib buuxinta saliidda ma aha mid aad u culus marka la barbar dhigo isbeddelka weyn; Sidaa darteed, marka la dayactiro jirka Transformer-ka, dhammaan Transformer-ka saliidda leh waxaa lagu qaadi karaa goobta iyadoo la adeegsanayo qalabka wax lagu qaado, daboolka sanduuqa waa la furayaa, jidhka ayaa kor loo qaadayaa, dayactirka ayaa lagu sameeyaa.

Darbiga taangiga waa la xoojiyey oo lagu sameeyay saxan bir ah, qaybtu waxay u badan tahay oval ama leydi, suufka caagga ah ayaa la dhigayaa inta u dhaxaysa cidhifka sanduuqa iyo daboolka, ka dibna daboolka hagaajinta ayaa loo isticmaalaa in lagu xidho. Cidhifka taangiga waxaa lagu habeeyay taangiga sare ee taangiga, daboolkuna wuxuu ku xiran yahay boodhka isticmaalka taangiga. Daboolka sanduuqa guud ahaan waa saxan fidsan waxaana lagu wada hagaajiyay harqoodka birta.

image011

 

2.4 Kulanka ugu dambeeya

iron core grounding

1. Isku imaatinka jirka

Waxa ka mid ah isku xidhka dahaarka iyo dawaynta madaxa gariiradda, xidhid gariiradda, gelin saxan iyo xajin, nus{0}}Tijaabada jidhka ee dhammaatay, isu imaatinka rasaasta (ay ku jirto isu-ururinta beddelka, samaynta rasaasta iyo isu-ururinta), kala badh{1}}Tijaabada jidhka oo dhammaatay, iyo foornada jidhka oo qallajisa (ay ku jirto cabbirka caabbinta dahaarka).

2. Wadarta guud

Waxaa ka mid ah dhamaystirka iyo xidhitaanka jidhka, cabbirka caabbinta dahaarka ee xudunta birta dhulka, kormeerka nadaafadda jidhka iyo cidhiidhiga qaybaha, fogaanta dahaadhka ee fiilooyinka iyo hogaanka, buuxinta saliidda (oo ay ku jiraan rakibidda qalabka transformer), tijaabada warshadda beddelka (sida xargaha dahaarka, iska caabinta isbeddelka, iska caabinta qiimaha DC, iwm.)

 

 

03 Tijaabinta

Tijaabada iska caabbinta dahaarka: tijaabi waxqabadka dahaadhka is beddelka, oo ay ku jiraan iska caabbinta dahaadhka u dhexeeya dabaylaha iyo dabaylaha, caabbinta dahaadhka u dhexeeya xudunta birta iyo dabaylaha, iwm.

Tijaabada iska caabinta Dc: Tijaabi caabbinta DC ee dabaylaha beddelka si loo xaqiijiyo xidhiidhka dabaysha iyo xasilloonida caabbinta.

Tijaabada danab sare: tijaabi iska caabinta korantada ee transformerka, oo ay ku jiraan qulqulka hadda iyo danab jabka ee hoos yimaada danabka la qiimeeyay.

Maya -Tijaabada rarka: tijaabi maya{1}} rarka luminta, maya{2}} rarida hadda, luminta birta iyo cabirrada kale ee taransfooriyaha si loo xaqiijiyo waxqabadka shaqo ee transformerka.

Tijaabada culeyska: tijaabi waxqabadka nidaaminta korantada, kor u kaca heerkulka iyo luminta rarka beddelka ee culeyska la qiimeeyay, xasilloonida iyo isku halaynta hoos xaaladaha culeyska muddada gaaban iyo kan dheer.

Tijaabada wareegga gaaban: tijaabi kulaylka daadanaya oo gaagaab - awoodda wax-ku-wareejinta hadda ee taransfooriyaha ee gaaban - gobolka wareegga, iyo sidoo kale ogaanshaha shaqaynaysa ee goynta degdegga ah{3}}qalabka ilaalinta muddada gaaban{4}}wareegga.

Tijaabada waxqabadka mashiinka oo dhan: tijaabi waxqabadka guud ee hawlgalka iyo xasilloonida beddelka, oo ay ku jiraan xasilloonida korantada wax soo saarka, hufnaanta, qodobka awoodda iyo cabbirrada kale.

 

transformer no load test
short circuit test

 

 

04 Baakaynta iyo dhoofinta

 

residential electrical transformer package
residential electrical transformer shipping

 

 

05 Goobta iyo Kooban

Waad ku mahadsan tahay xiisahaaga saddexdayada{{0}wajiga{1}} Iyada oo ay la socoto waxqabadkeeda gaarka ah, sifooyinka badbaadada la isku halayn karo, iyo la qabsiga wax ku oolka ah, badeecadani waxay bixisaa taageero awood leh oo hufan oo xasilloon oo loogu talagalay nidaamyada qaybinta warshadaha, ganacsiga, iyo dadweynaha. Waxaan u heellannahay in aan u dhigno baahida macaamiisha udub-dhexaadka himiladeena, isku darka tignoolajiyada horumarsan iyo adeegyada qaaliga ah si aan u gaarsiinno xalalka korantada ee adiga kugu habboon. Waxaan rajeyneynaa inaan kula shaqeyno si aan u wadno hal-abuurka iyo waaritaanka warshadaha tamarta! Wixii macluumaad dheeraad ah ama taageero farsamo, fadlan xor u tahay inaad nala soo xidhiidho wakhti kasta!

customized power solutions

 

Hot Tags: Beddelka Korontada ee deegaanka, soo saaraha, alaab-qeybiyaha, qiimaha, qiimaha