1000 KVA suuf Ku rakiban Transformers-34.5/0.48 KV|USA 2025

1000 KVA suuf Ku rakiban Transformers-34.5/0.48 KV|USA 2025

Dalka la geynayo: Ameerika 2025
Awoodda: 1000KVA
Voltage: 34500GrdY/19920V-480Y/277
Sifada: Solar{0}}Naqshad La Habeeyay
U dir sooji

Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha ugu kalsoonida badan iyo alaab-qeybiyeyaasha 1000 kva pad ku rakiban transformers{6}}34.5/0.48 kv|USA 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

 

1000 KVA Pad Mounted Transformers

 

 

01 Guud

1.1 Sharaxaada Mashruuca

Dhirta PV qoraxda run ahaantii uma shaqeeyaan sida culeysyadaada warshadaha ee caadiga ah. Iftiinka qorraxdu saacadba saacada ayay is beddeshaa, daruuruhuna way soo galaan oo dibadda u baxaan, beddelayaashuna inta badan waxay ku socdaan qayb qayb ah - taas oo asal ahaan ka dhigan taransfooriyaha uu arko dhammaan noocyada kala duwan ee isdhaafka ah, aan la saadaalin karin, iyo mararka qaarkood si lama filaan ah.

Mashruucan, waxaan u baahnay in aan kor ugu qaadno 480Y/277 V dhanka rogaha ilaa 34.5 kV (34500GrdY/19920 V) si aan ugu quudinno shabaqyada. Markaa haa, 1000 kVA saddex-saf-weji{8}ku rakiban taransfooraha waa nooc ka mid ah wadnaha nidaamka - la'aantiis, waxba run ahaantii dhaqaaqin.

Maaddaama ay bannaanka tahay, nashqadayntu waxay ahayd inay gaadho heerarkii caadiga ahaa--, isla mar ahaantaana, waanu u tanaasuli kari waynay himilooyinka: isku xidhka khadka xasiloon, nidaaminta danab dabacsan, iyo hawlgal la isku halayn karo muddo 20+ sano ah. Taasi waa meesha ay Scotech ka soo gashay. Waxaanu u qaabaynay si ay u wajahdo caqabado badan hal mar: ilaalinta hawl wadeenada kuwa dhintay - dhismaha hore, ka dhigaysa mid adag ka hortagga cimilada leh daxalka{6}}, iyada oo la isticmaalayo FR3 saliid ester dabiici ah badbaadada deegaanka iyo dabka, iyo dejinta wax kasta si kormeerka iyo dayactirku aanay madax xanuun u ahayn.

 

 

 

1.2 Tilmaamaha Farsamada

1000kVA saddex waji oo suuf ah oo ku rakiban tafatirka tafatirka iyo xaashida xogta

loo geeyey
Ameerika
Sannadka
2025
Nooca
Saddex weji suuf Buur Transformer
Heerka
IEEE
Awood lagu qiimeeyay
1000KVA
Soo noqnoqda
60HZ
Quudinta
Loop
Hore
dhintay
Marxaladda
Saddex
Nooca qaboojinta
KNAN
Insulant dareere ah
FR3 Saliid
Korantada aasaasiga ah
34500GrdY/19920V
Voltage Secondary
480Y/277
Kooxda Vector
YNyn0
Qalabka dabaysha
Aluminium
Caqabada
5.75%
Waxtarka iyo khasaaraha Heerka
DOE 2016
Taabo Beddelka
4-BOOSE DEJINTA XULASHADA
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
1300 W
Load Lumista
6940 W
Agabka
Habaynta caadiga ah

 

1.3 Sawirro

1000KVA saddex weji suuf ah oo ku rakiban cabbirka beddelka iyo faahfaahinta miisaanka

1000 KVA Pad Mounted Transformers drawing 1000 KVA Pad Mounted Transformers nameplate

 

 

02 Naqshadaynta iyo Waxqabadka Transformer

{{0}Booska Loadbreak Switch

4-Position Loadbreak Switch

Transformer-kani waxa uu adeegsadaa 4{1}} culayska booska{2}}, oo loogu talagalay codsiyada quudiyaha PV ee labada ilood.
Afarta boos waxay bixiyaan hagid dabacsan iyo hawlgal badbaado leh:
ISHA A & B - TABADDA
Isha A - TABADDA
ISHA B - TABADDA
ISHA A & B - TABADDA
Jagooyinkani waxay awood u siinayaan culays badbaado leh {{0} jebinta jebinta,{1}}doorashada isha, oo tabo{2}}go'doominta wareega{3}}kuwa ku haboon talaabada PV-Transfomerayaasha u baahan qaabaynta quudiyaha la isku halayn karo.

 

2.2 Nidaamka qaboojinta iyo qaboojinta

Transformer-kan, waxaan u dooranay FR3 saliid ester dabiici ah sababtoo ah waxay siisaa faa'iidooyin cad oo loogu talagalay codsiyada PV. Barta toosan ee sare waxay si weyn u wanaajisaa badbaadada dabka - oo ah arrin muhiim u ah rakibaadda dibadda. FR3 sidoo kale waa biodegradable, taageerta shuruudaha u hoggaansanaanta deegaanka. Waxa ka sii muhiimsan, waxa ay bixisaa wax qabad kulayleed heer sare ah, taas oo u oggolaanaysa nidaamka dahaarka in uu xakameeyo meertada iyo heerkulka - kala duwanaanshaha culeyska la wado ee caadiga ah ee goobaha PV qoraxda.
Nidaamka qaboojinta waa KNAN, dabiiciga ah -ester u dhigma ONAN. Codsiyada PV halkaas oo raritaanku si weyn u kala duwanaan karo maalinta oo dhan, KNAN waxay bixisaa qaboojin deggan oo la isku halleyn karo, hubinta waxqabadka joogtada ah ee hoos imanaya xaaladaha qorraxda ee isbedbeddelaya.

FR3 natural ester oil

 

2.3. Haanta & Naqshad Badbaadada

1000 KVA Pad Mounted Transformers tank

Maadaama uu kani yahay suuf -Transformer ku rakiban oo bannaanka fadhiya, waxay ahayd inaan ka fikirno badbaadada iyo adkeysiga xag kasta. Waxa aanu u qaabaynay iyada oo meyd ah - dhismo hore - si qof kasta oo ka shaqeeya agteeda uu u ahaado mid badbaado leh - iyo loop{5}} qaabaynta quudinta si ay isku xidhka xidhidhku u noqdo mid dabacsan.

Taangiga iyo armaajooyinka waxay heleen daxal - adkaysi u leh, UV- dahaar aan caddayn, sababtoo ah run ahaantii, qofna ma rabo tafatirka daxalaysan ka dib sannad qorraxda iyo roobka. Waxaan sidoo kale dhisnay tallaabooyin aan kaga hortagayno xatooyada ama faragelinta shilalka ah. Dabcan, saliidda FR3 kaliya kama caawinayso badbaadada dabka - waxay sidoo kale hoos u dhigtaa saamaynta deegaanka.

 

 

03 Joojinta iyo Qaybaha Ilaalinta

3.1. Burburinta & Joojinta

Dhinaca HV (34.5kV):
• 200A Loadbreak / Deadbreak duurka
• Xirayaasha hillaaca
• Dhul-dhigid iyo gaashaan-dhig habboon
HV bushing
LV bushing Dhinaca LV (480V):
• 12-dalool maxsadaha
H0/X0 dhibcood dhexdhexaad ah ayaa si gaar ah loo soo saaray
Dhammaan qaybaha waxay la kulmaan heerarka ANSI ee farsamada, kulaylka, iyo waxqabadka korontada.

 

3.2. Agabka & Ilaalinta

 

suufka caadiga ah ee ANSI{0}} korka isku xidhka:
• Heerkulka saliidda, heerka saliidda, mitirka heerkulka dabaysha
• Fiyuusyada HV, furayaasha rarka, furayaasha 4-meelood ee xulashada
• Dhinac{0}}ku rakiban guddi qalabeedka la socodka iyo ilaalinta
• Dejinta iyo gaashaandhigga dibadda
• Ilaalinta hillaaca (lagu qiimeeyay meelaynta xidhista)

isolated H0/X0
VACUUM PRESSURE GAUGE
Oil level gauge
PRESSURE RELIEF VALVE
Side-mounted instrument cabinet
12 holes ground bar

 

04 Baakadaha iyo gaadiidka

1000 kVA PV step-up transformer-packing-1
1000 kVA PV step-up transformer-packing-2

 

 

05 Goobta iyo Kooban

Talaabada 1000 kVA PV{1} kor u kaca taransiyaha waxa ay ilaalisaa korantada shabkada mid xasiloon, markaa rogayaasha ayaa si habsami leh u shaqeeya. Waxaa ka buuxsamay FR3 saliid ester dabiici ah, waa deegaan saaxiibtinimo waxayna hoos u dhigtaa khatarta dabka.

Naqshadu waxa ay qabataa culaysyo aan - PV socda, kaas oo gacan ka geysta kordhinta cimriga, iyo OLTC waxa ay maamushaa korontada degdega ah, iyada oo ka faa'iidaysanaysa tamarta qoraxdaada.

Markaad suuf ku rakiban tahay, way dhakhso badan tahay in la rakibo, waxay qaadataa meel yar, wayna fududahay in la dayactiro. Si buuxda ugu hoggaansan heerarka koronto ee Waqooyiga Ameerika, waxay si fiican ugu shaqeysaa dhirta PV la qaybiyey iyo kuwa dhexe.

 

Hot Tags: 1000 kva suuf ku rakiban transformers-34.5 / 0.48 kv|usa 2025, Shiinaha 1000 kva suuf ah oo ku rakiban transformers-34.5/0.48 kv|USA 2025 saarayaasha, alaab-qeybiyeyaal, warshad