Jiangshan Scotech Electric Co., Ltd waa mid ka mid ah soosaarayaasha iyo alaab-qeybiyeyaasha 25 kva ugu kalsoonida badan{7}}14.4/0.12*0.24 kv kanada 2025 ee Shiinaha. Fadlan xor u noqo inaad iibsato alaab qiimo jaban oo iib ah halkan oo ka hel jaantusyada warshadeena. Nala soo xidhiidh wixii faahfaahin ah.

 

25 kVA single pole transformer

SCOTECH – la isku halayn karo 25 kVA soo saaraha iyo alaab-qeybiyaha

 

 

01 Guud

1.1 Sharaxaada Mashruuca

Midka kaliya ee 25 kVA -Tarlaabiyaha Wajiga Ku dhejisan ee SCOTECH waa sahlan tahay in lagu rakibo tiirarka tamarta sare. Waa mid aad loo isku halleyn karo waxayna la socotaa qalabyada lagama maarmaanka ah. Cidhifyada -Cutubyada ku rakiban ee sidan oo kale ah waxay ku fiican yihiin aagagga miyiga ah ama meelaha leh khadadka sare. Way fududahay in la rakibo, fududahay in la dayactiro, iyo kharash{6}}wax ku ool u ah bulshooyinka cufnaanta hoose-

Transformer-kani waxa uu hoos u dhigayaa{0}koronta sare (24,940 GRDY/14,400 V) ilaa wax soo saarka 120/240 V ee nabdoon ee guryaha iyo ganacsiyada yaryar ee shabakadaha 60 Hz. Waxay leedahay dabaylaha aluminium iyo xudunta birta ah ee la dahaadhay. Hufnaantu way ka weyn tahay ama la mid tahay 98.87%, iyada oo aan lahayn{11}} lumin 85 W iyo luminta 254 W. Caqabadkeedu waa 1.97% (± 10%), hubinta korantada deggan ee culeyska saaran.

Waxa ka mid ah wax aan -Load Tap Changer (NLTC) oo wata ±2×2.5% kala duwanaanta taabka ee hagaajinta korantada. Xadhiga 18kV ee sarreeya-Valtaj xidhaha waxa uu ka ilaaliyaa koronto-bixiyeha xad-dhaafka iyo hillaaca. Cutubku wuxuu isticmaalaa qaboojinta ONAN iyo dahaarka saliidda macdanta, oo leh haan xidhan oo loogu talagalay waxqabadka bannaanka ee la isku halayn karo. Transformer-ku waxa uu isticmaalaa qaboojinta ONAN iyo dahaarka saliidda macdanta, oo leh nashqad taangiga xidhan oo loogu talagalay hawlgal dibadda ah oo la isku halayn karo. Waxaa si fudud loogu dhejin karaa tiirarka alwaax ama la taaban karo, oo u baahan dayactirka ugu yar.

Ku habboon xaafadaha la deggan yahay, beeraha, iyo tas-hiilaadka yar yar ee ganacsiga, transformer-kani wuxuu bixiyaa awood la isku halayn karo ee shabakadaha qaybinta miyiga iyo xaafadaha, fidinta shabakadda, iyo meelaha u nugul dhacdooyinka qulqulka ama hillaaca.

 

 

 

1.2 Tilmaamaha Farsamada

25kVA qeexida beddelka tiirka hal tiir iyo xaashida xogta

loo geeyey
Kanada
Sannadka
2025
Nooca
Transformer ku rakiban tiirarka
Heerka
CSAC2.2-06/C802.1-23
Awood lagu qiimeeyay
25KVA
Soo noqnoqoshada
60HZ
Polarity
Wax lagu daro
Marxaladda
Keli
Nooca qaboojinta
ONAN
Insulant dareere ah
Saliidda Macdanta
Korantada aasaasiga ah
24940GRDY/14400 V
Voltage Secondary
120/240 V
Kooxda Vector
II6
Qalabka dabaysha
Aluminium
Caqabada
1.97%(±10%)
Waxtarka iyo khasaaraha Heerka
Ka weyn ama la mid ah 98.87%
Taabo Beddelka
NLTC
Riixista Range
±2*2.5%
Wax Xamuul ah ma jiro
85 W
Lumitaanka Korantada ee La qiimeeyay
254 W
Agabka
18kV HV Xadhige

 

1.3 Sawirro

25kVA sawir beddelka tiirka hal tiirka ah iyo warqad magaceed

25 kVA single pole transformer drawing 25 kVA single pole transformer nameplate

 

 

02 Wax-soo-saarka

2.1 Core

25 kVA single pole transformer iron core

Wadnaha tiirka -Transformer-ka lagu rakibay waa xudunta birta, oo badiyaa ka samaysan lakabyo bir ah oo dhuuban. Xuddunta waxay caawisaa tamarta magnetic inay si fudud u dhex marto dabaylaha aasaasiga ah iyo kan sare. Tani waxay u ogolaanaysaa transformer-ku in uu bixiyo danab joogto ah oo leh tamar yar oo uu u shaqeeyo si kalsooni leh maalin kasta.

 

2.2 Dabaylaha

Transformers-yadani waxay leeyihiin foil aluminium ah - dhinaca korantada ee hooseeya. Siligga naxaasta ah waxa loo isticmaalaa dhinaca sare - dhinaca korantada Warshadu waxay si gooni gooni ah u waddaa labada hab-raac iyada oo leh mashiinno gaar ah iyo shaqaale tababaran. Waxaan tijaabinaynaa dahaarka, cabbirka, iyo iska caabinta gariiradda kasta si aan u hubinno in cutub kasta uu u shaqeeyo sidii loogu talagalay.

25 kVA single pole transformer coil

 

2.3 Haanta

25 kVA single pole transformer oil tank

Jirka haanta, daboolka, iyo dhammaan qaybaha alxanka dibadda waxa lagu daaweeyaa ka-hortagga - daxalka alxanka ka dib si ay ula qabsadaan bannaanka, qoyaanka, xeebaha, iyo bay'adaha kale ee u nugul daxalka ama buufinta milixda. Habkani waxa uu hubinayaa in transformer-ku uu si deggan ugu shaqayn karo muddo dheer, xataa meelaha ay ka jiraan neecawda badda iyo huurka badan.

 

 

03 Tijaabinta

25 kVA single pole transformer testing-1
25 kVA single pole transformer testing-2

 

 

04 Baakadaha iyo gaadiidka

4.1 Baakad

25 kVA single pole transformerpacking-1
25 kVA single pole transformerpacking-2

 

4.2 dhoofinta

25 kVA single pole transformer shipping-1
25 kVA single pole transformer shipping-2

 

 

05 Tixgelinta Badbaadada iyo Dayactirka

25 kVA single pole transformer
 

Xataa deegaan xeebeedka qallafsan, tiirka -Transformers ee lagu rakibay waa la isku halayn karaa, laakiin kormeerka joogtada ahi waa lama huraan. milix - hawo rarran, duufaanada xagaaga, iyo barafka jiilaalka waxay soo dedejin karaan daxalka ama waxay abuuraan diiqad farsamo. Khataraha muhiimka ah waxaa ka mid ah:
• Saliida oo daadato
• Hillaaca{0}ku-guuldarrooyinka sababay
• Culayska xad dhaafka ah inta lagu jiro baahida degdega ah
Si loo dhimo khataraha fuulitaanka, adeegyadu waxay inta badan ku tiirsan yihiin dareemayaasha kulaylka iyo kormeerka diyaaradaha aan duuliyaha lahayn si ay ula socdaan xaaladda beddelka ee dhulka.

 